Regency FG37-LPG, FG37-NG installation manual Maintenance Instructions, GOLD-PLATED Doors

Page 22

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

Any maintenance required accessing the glass door of the unit must be performed by an authorized service person.

1)Always unplug the power cord before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vac- uuming at least once a year. When cleaning the logs, use a soft clean brush as the logs are fragile and easily damaged.

2)Clean glass (never when unit is hot), ap- pliance, louvres, and door with a damp cloth. Never use an abrasive cleaner. The gold louvres (and optional gold door) may be scratched if abrasives are used to clean them.

The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint (not with wall paint). Regency uses StoveBright Paint - Metallic Black #6309.

3)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call an author- ized service person.

4)The appliance and flueing system must be inspected before use, and at least annual- ly, by an authorized field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

During the annual service call, the burners should be removed from the burner tray and cleaned. Replace the embers - do not block the pilot or burner ports.

5)Keep the area near the appliance clear and free from combustible materials, gasoline and other flammable vapours and liquids.

WARNING: CHILDREN AND ADULTSSHOULDBEALERTEDTO THEHAZARDSOFHIGHSURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOIDBURNS OR CLOTHING IGNITION. YOUNG CHILDRENSHOULDBECAREFUL- LYSUPERVISEDWHENTHEYARE IN THE SAME ROOM AS THE AP- PLIANCE.

CAUTION: ANY SAFETY SCREEN ORGUARDREMOVEDFORSERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL AN AUTHORIZEDSERVICETECHNI CIAN TO INSPECT THE APPLI- ANCEANDTOREPLACEANYPART OF CONTROL SYSTEM AND ANY GASCONTROLWHICHHASBEEN UNDERWATER.

6) Verify proper operation after servicing.

GOLD-PLATED DOORS

The 24 carat gold plated finish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and will void the warranty. Clean any fingerprints off before turning the unit on.

22

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

Image 22
Contents Manual Please Keep These Instructions For Future ReferenceTo the New Owner Table of Contents Data Plate General Safety Information InstallationSpecifications Save These InstructionsClearances to Combustibles Installation ChecklistLocating Your Regency GAS Stove Combustion and Ventilation AIRExterior Flue Termination Locations Clearance k in mmPlanning Your Fluing Installation Fluing Installation PrecautionsSafety Precautions for Installer FluingOffset to Vertical Terminations Vertical Terminations With Co-linear Flex SystemFlue Restrictor Position Optional Components Horizontal InstallationsDiagram Snorkel TerminationsBelow Grade Snorkel Installation Hint Apply sealant to female endVertical Termination with CO-LINEAR Flex System GAS ConnectionAntenna Control Box Cover Pilot Orifice Extrusion Assembly TubeBurner Orifice Jumper LocationAdjusting the Outlet Pressure Cable Electric ModulatorLOG SET Installation Aeration AdjustmentNG 10mm open LPG 10mm open Notch Cutout PinCutoutNotch Louvre Installation GAS Pipe Pressure TestingT. Valve Description Wiring Optional Remote ControlFinal Check Operating Instructions Summary Controls Pilot AdjustmentNormal Operating Sounds GAS Appliances Settle on the floor Copy of the Lighting Plate Instructions918-332a Maintenance Instructions MaintenanceGOLD-PLATED Doors LOG Replacement Latch AdjustmentGlass Replacement FAN Maintenance Rectly sealedManual Switch Reset Cables Pin Ground Molex Connector WireRemoving Valve Tray Parts List Electronic Components Parts ListFG37 Main Assembly FG37 Burner & LOG Assembly FG37 Door Assemblies FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater Conditions WarrantyWarranty Lifetime Exclusions

FG37-NG, FG37-LPG specifications

The Regency FG37-LPG and FG37-NG are premium gas fireplaces that blend elegance with cutting-edge technology, making them ideal for modern homes. Designed by Regency, a leader in the fireplace industry, these models offer both aesthetic appeal and highly efficient heating capabilities.

The FG37-LPG is powered by liquid propane, while the FG37-NG utilizes natural gas, providing versatile options to meet different customer needs. Both models feature a sleek, contemporary design that complements various interior styles, making them a focal point in any living space. The large viewing area allows for an expansive display of flames, contributing to a warm, inviting atmosphere.

One of the standout features of the Regency FG37 series is its advanced heating technology. The fireplaces employ a high-efficiency burner system that maximizes heat output while minimizing gas consumption. This efficiency not only leads to lower energy bills but also reduces environmental impact, aligning with sustainability goals.

Additionally, the Regency FG37 models feature advanced flame control technology. Users can easily adjust the flame intensity, allowing for a custom heating experience that suits personal preferences and room sizes. This versatility makes them suitable for a variety of applications, from cozy family rooms to expansive open-concept spaces.

For added convenience, the fireplaces are equipped with a modern electronic ignition system, ensuring reliable and hassle-free startup. Customers appreciate the included remote control, which provides effortless operation from the comfort of their seats. As an optional upgrade, the Regency Smart Home Control system allows for integration with smart home devices, enabling users to manage their fireplace from their smartphones or tablets.

Safety is paramount in the design of the FG37-LPG and FG37-NG. Both models come with a built-in safety shutoff valve, ensuring that the gas supply is automatically cut off in the event of an emergency. The units also feature a glass door that remains cool to the touch, providing peace of mind for households with pets and children.

Overall, the Regency FG37-LPG and FG37-NG epitomize the perfect merger of style, efficiency, and safety. With their striking design, advanced technologies, and user-friendly features, these gas fireplaces are an excellent choice for anyone seeking to enhance their home with the luxury and warmth of a modern fireplace.