The REGENCY Rear Flued Room Sealed Free- standing Gas Stove must be installed in accord- ance AG601 and NZS 5261 and with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

SPECIFICATIONS

Fuels: FG37-NG is approved for use with NG.

FG37-LPG is approved for use with liquefied petroleum gases (LPG).

Electrical: 240 V

A.C. system.

Circulation Fan:

Two Speed

Log Sets: Ceramic fibre, 7 per set.

Flue System:

Axial (6-5/8" (168mm) outer / 4" (102mm) inner liner) rigid flue and

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿Riser Vent Terminal.

Safe installation and operation of this appliance requires common sense, however, please be aware of the following:

INSTALLATION AND REPAIRS SHOULDBEDONEBYANAUTHOR- IZED SERVICE PERSON. THIS AP- PLIANCESHOULDBEINSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BYANAUTHORIZEDSERVICEPER- SON. MORE FREQUENT CLEAN- ING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPET- ING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT, BURNERSANDCIRCULATINGAIR PASSAGEWAYS OF THE APPLI- ANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BEALERTEDTOTHEHAZARDSOF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS,ANDSHOULDSTAYAWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

1)Provide adequate clearances for servic- ing, proper operation and around the air openings into the combustion chamber.

2)The appliance must be installed on a flat, solid, continuous surface (e.g. wood, met- al, concrete). This may be the floor, or it can be raised up on a platform to enhance its visual impact. The appliance may be in- stalled on carpeting, tile, wood flooring or other combustible material, because the appliance's metal pedestal base extends the full width and depth of the appliance. The REGENCY Rear Flued Room Sealed Freestanding Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner.

3)The REGENCY Rear Flued Room Sealed Freestanding Gas Stove is approved for manufactured home installations, see pag- es 6 to 9 for the required flue arrangements. If installed into a manufactured home the unit must be bolted down to the floor.

4)We recommend that you plan your installa- tion on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized building inspector review your plans before installation.

GENERAL SAFETY

INFORMATION

1)The appliance shall be installed in accord- ance with the manufacturer's installation instructions, local gas fitting regulations, municipal building codes, water supply reg- ulations, electrical wiring regulations, with AS5601-2004 (AGA gas installation code) NZS 5261 (New Zealand)

2)Installation and repair should be done ONLY by an authorised person.

3)DONOTCONNECTTOMASONARYFLUE.

4)This appliance must be connected to the specified flue and termination cap to the outside of the building enve- lope. Never flue to another room or inside a building. Make sure that the flue is fitted as per Flueing instruc- tions.

5)Inspect the flueing system annually for blockage and any signs of deterioration.

6)Flueing terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

9)Wear gloves and safety glasses for pro- tection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appli- ance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorised service person. An authorised service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

5

Image 5
Contents Please Keep These Instructions For Future Reference ManualTo the New Owner Table of Contents Data Plate Specifications InstallationGeneral Safety Information Save These InstructionsLocating Your Regency GAS Stove Installation ChecklistClearances to Combustibles Combustion and Ventilation AIRClearance k in mm Exterior Flue Termination LocationsSafety Precautions for Installer Fluing Installation PrecautionsPlanning Your Fluing Installation FluingFlue Restrictor Position Vertical Terminations With Co-linear Flex SystemOffset to Vertical Terminations Diagram Horizontal InstallationsOptional Components Snorkel TerminationsHint Apply sealant to female end Below Grade Snorkel InstallationGAS Connection Vertical Termination with CO-LINEAR Flex SystemBurner Orifice Pilot Orifice Extrusion Assembly TubeAntenna Control Box Cover Jumper LocationCable Electric Modulator Adjusting the Outlet PressureNG 10mm open LPG 10mm open Aeration AdjustmentLOG SET Installation Notch PinCutoutNotch Cutout T. Valve Description GAS Pipe Pressure TestingLouvre Installation Final Check Optional Remote ControlWiring Operating Instructions Normal Operating Sounds GAS Appliances Pilot AdjustmentSummary Controls 918-332a Copy of the Lighting Plate InstructionsSettle on the floor GOLD-PLATED Doors MaintenanceMaintenance Instructions Glass Replacement Latch AdjustmentLOG Replacement Rectly sealed FAN MaintenanceRemoving Valve Tray Pin Ground Molex Connector WireManual Switch Reset Cables Electronic Components Parts List Parts ListFG37 Main Assembly FG37 Burner & LOG Assembly FG37 Door Assemblies FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater Warranty Lifetime WarrantyConditions Exclusions

FG37-NG, FG37-LPG specifications

The Regency FG37-LPG and FG37-NG are premium gas fireplaces that blend elegance with cutting-edge technology, making them ideal for modern homes. Designed by Regency, a leader in the fireplace industry, these models offer both aesthetic appeal and highly efficient heating capabilities.

The FG37-LPG is powered by liquid propane, while the FG37-NG utilizes natural gas, providing versatile options to meet different customer needs. Both models feature a sleek, contemporary design that complements various interior styles, making them a focal point in any living space. The large viewing area allows for an expansive display of flames, contributing to a warm, inviting atmosphere.

One of the standout features of the Regency FG37 series is its advanced heating technology. The fireplaces employ a high-efficiency burner system that maximizes heat output while minimizing gas consumption. This efficiency not only leads to lower energy bills but also reduces environmental impact, aligning with sustainability goals.

Additionally, the Regency FG37 models feature advanced flame control technology. Users can easily adjust the flame intensity, allowing for a custom heating experience that suits personal preferences and room sizes. This versatility makes them suitable for a variety of applications, from cozy family rooms to expansive open-concept spaces.

For added convenience, the fireplaces are equipped with a modern electronic ignition system, ensuring reliable and hassle-free startup. Customers appreciate the included remote control, which provides effortless operation from the comfort of their seats. As an optional upgrade, the Regency Smart Home Control system allows for integration with smart home devices, enabling users to manage their fireplace from their smartphones or tablets.

Safety is paramount in the design of the FG37-LPG and FG37-NG. Both models come with a built-in safety shutoff valve, ensuring that the gas supply is automatically cut off in the event of an emergency. The units also feature a glass door that remains cool to the touch, providing peace of mind for households with pets and children.

Overall, the Regency FG37-LPG and FG37-NG epitomize the perfect merger of style, efficiency, and safety. With their striking design, advanced technologies, and user-friendly features, these gas fireplaces are an excellent choice for anyone seeking to enhance their home with the luxury and warmth of a modern fireplace.