Regency FG37-NG, FG37-LPG Copy of the Lighting Plate Instructions, Settle on the floor, 918-332a

Page 21

OPERATING INSTRUCTIONS

COPY OF THE LIGHTING PLATE INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if not,

follow the current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

A)BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will

settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any appliance

-Do not touch any electric switch, do not use any phone in your building

-Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s in- structions.

-If you cannot reach your gas supplier, call the fire department.

B)Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this label.

1)Plug the power cord into a power outlet.

2)Press and release the ON/OFF button once to start the unit.

3)After approximately 3 seconds the spark ignition system will spark for 25 seconds to light the main burner.

4)If the main burner does not light, check the gas and reset the unit.

TO TURN OFF GAS APPLIANCE

1) Press the ON/OFF button once.

2) Turn off all electric power to the unit if

 

service is to be performed.

DO NOT REMOVE THIS INSTRUCTION PLATE

918-332a

WARNING:

DO NOT SPRAY AEROSOLS IN THE VICINITY OF

THIS APPLIANCE WHILE IN OPERATION.

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

21

Image 21
Contents Please Keep These Instructions For Future Reference ManualTo the New Owner Table of Contents Data Plate Specifications InstallationGeneral Safety Information Save These InstructionsLocating Your Regency GAS Stove Installation ChecklistClearances to Combustibles Combustion and Ventilation AIRClearance k in mm Exterior Flue Termination LocationsSafety Precautions for Installer Fluing Installation PrecautionsPlanning Your Fluing Installation FluingVertical Terminations With Co-linear Flex System Offset to Vertical TerminationsFlue Restrictor Position Diagram Horizontal InstallationsOptional Components Snorkel TerminationsHint Apply sealant to female end Below Grade Snorkel InstallationGAS Connection Vertical Termination with CO-LINEAR Flex SystemBurner Orifice Pilot Orifice Extrusion Assembly TubeAntenna Control Box Cover Jumper LocationCable Electric Modulator Adjusting the Outlet PressureAeration Adjustment LOG SET InstallationNG 10mm open LPG 10mm open PinCutout Notch CutoutNotch GAS Pipe Pressure Testing Louvre InstallationT. Valve Description Optional Remote Control WiringFinal Check Operating Instructions Pilot Adjustment Summary ControlsNormal Operating Sounds GAS Appliances Copy of the Lighting Plate Instructions Settle on the floor918-332a Maintenance Maintenance InstructionsGOLD-PLATED Doors Latch Adjustment LOG ReplacementGlass Replacement Rectly sealed FAN MaintenancePin Ground Molex Connector Wire Manual Switch Reset CablesRemoving Valve Tray Electronic Components Parts List Parts ListFG37 Main Assembly FG37 Burner & LOG Assembly FG37 Door Assemblies FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater Warranty Lifetime WarrantyConditions Exclusions

FG37-NG, FG37-LPG specifications

The Regency FG37-LPG and FG37-NG are premium gas fireplaces that blend elegance with cutting-edge technology, making them ideal for modern homes. Designed by Regency, a leader in the fireplace industry, these models offer both aesthetic appeal and highly efficient heating capabilities.

The FG37-LPG is powered by liquid propane, while the FG37-NG utilizes natural gas, providing versatile options to meet different customer needs. Both models feature a sleek, contemporary design that complements various interior styles, making them a focal point in any living space. The large viewing area allows for an expansive display of flames, contributing to a warm, inviting atmosphere.

One of the standout features of the Regency FG37 series is its advanced heating technology. The fireplaces employ a high-efficiency burner system that maximizes heat output while minimizing gas consumption. This efficiency not only leads to lower energy bills but also reduces environmental impact, aligning with sustainability goals.

Additionally, the Regency FG37 models feature advanced flame control technology. Users can easily adjust the flame intensity, allowing for a custom heating experience that suits personal preferences and room sizes. This versatility makes them suitable for a variety of applications, from cozy family rooms to expansive open-concept spaces.

For added convenience, the fireplaces are equipped with a modern electronic ignition system, ensuring reliable and hassle-free startup. Customers appreciate the included remote control, which provides effortless operation from the comfort of their seats. As an optional upgrade, the Regency Smart Home Control system allows for integration with smart home devices, enabling users to manage their fireplace from their smartphones or tablets.

Safety is paramount in the design of the FG37-LPG and FG37-NG. Both models come with a built-in safety shutoff valve, ensuring that the gas supply is automatically cut off in the event of an emergency. The units also feature a glass door that remains cool to the touch, providing peace of mind for households with pets and children.

Overall, the Regency FG37-LPG and FG37-NG epitomize the perfect merger of style, efficiency, and safety. With their striking design, advanced technologies, and user-friendly features, these gas fireplaces are an excellent choice for anyone seeking to enhance their home with the luxury and warmth of a modern fireplace.