Cisco Systems 3550 manual “Technical Specifications.”, Results” section on page, Problem, Solution

Models: 3550

1 86
Download 86 pages 59.76 Kb
Page 53
Image 53
Problem

Chapter 3 Troubleshooting

Diagnosing Problems

Table 3-1describes some common problems and their solutions.

Table 3-1 Common Problems and Solutions

Problem

Solution

 

 

System LED is not on, and the

Check that the power cable is connected to the switch and to a

switch does not run POST.

known power source.

 

Test the power cable on another switch.

 

Connect a working power cable from another switch.

 

 

System LED is amber.

An internal fan fault is detected. Either check the switch itself,

 

or use the show env user EXEC command to check for a failed

 

fan.

 

The switch might be overheating. Use the show env user EXEC

 

command to check for an overtemperature condition. If there is

 

an overtemperature condition:

 

Place the switch in an environment that meets the

 

environmental requirements given in Appendix A,

 

“Technical Specifications.”

 

Make sure that the fan intake and exhaust areas are clear.

 

A fatal POST error is detected. See the “Understanding POST

 

Results” section on page 3-1.

 

 

Catalyst 3550 Switch Hardware Installation Guide

 

OL-6155-01

3-3

 

 

 

Page 53
Image 53
Cisco Systems 3550 manual “Technical Specifications.”, Results” section on page, Problem, Solution