INSTALLATION
Installing into Existing
Woodstove Flue System
1)Clean existing chimney system.
2)Install stove pipe adapter
3)Install any reducers that may be needed to fit 6" flue pipe adapter.
4)Run 4" flex liner into existing chimney.
5)Slip liner through 6" flue pipe and hook up to flue collar with screws.
Note: For ease of instal- lation, use a slip section when in- s t a l l i n g
with a ver- tical flue pipe.
GAS CONNECTION
The gas connection is a 3/8" NPT rigid pipe. The gas line can be rigid pipe or to make installation easier, use a listed flexible connector and/or copper pipe if allowed by local codes. For minimum and maximum supply pressure see the System Data table below.
Note: During any pressure testing of the gas supply piping system that exceeds test pressures of 1/2 psig, this appliance and its indi- vidual
Output capacity:
The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
SYSTEM DATA
(For 0 to 2,000 feet altitude)
Orifice Sizes: |
|
|
|
Burner | Natural Gas | #36 | |
Burner | Propane | #52 | |
|
|
| |
Max. Input Rating |
|
| |
Natural Gas | 33,000 Btu/h |
| |
Propane | 33,000 Btu/h |
| |
Min. Input Rating |
|
| |
Natural Gas | 17,000 Btu/h |
| |
Propane | 17,000 Btu/h |
| |
| |||
Output Capacity with blower Off | |||
Natural Gas | 23,200 Btu/h |
| |
Propane | 23,100 Btu/h |
| |
Output Capacity with blower On | |||
Natural Gas | 24,600 Btu/h |
| |
Propane | 24,420 Btu/h |
| |
|
|
| |
Supply Pressure |
|
| |
Natural Gas | min. | 5.0" | w.c |
| max. | 8.0" | w.c. |
Propane | min. | 12.0" | w.c. |
| max. | 13.0" | w.c. |
|
|
| |
Manifold Pressure High |
|
| |
Natural Gas | 3.8" +/- 0.2" w.c. | ||
Propane | 11" +/- 0.2" w.c. | ||
Manifold Pressure Low |
|
| |
Natural Gas | 1.1" +/- 0.2" w.c. | ||
Propane | 2.9" +/- 0.2" w.c. |
Electrical: 120V, 1.13A, 60 Hz.
Circulation Fan: (optional) 2 speed 75/125 CFM.
Log Set: Ceramic fiber, 4 per set.
HIGH ELEVATION
This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1
SYSTEM DATA
(For 2,000 to 4,500 feet altitude)
Orifice Sizes: |
|
|
Burner | Natural Gas | #38 |
|
| |
Max. Input Rating |
| |
Natural Gas | 29,000 Btu/h | |
Min. Input Rating |
| |
Natural Gas | 15,300 Btu/h |
Output Capacity with blower Off
Natural Gas | 20,400 Btu/h |
Output Capacity with blower On
Natural Gas | 21,600 Btu/h |
GAS PIPE
PRESSURE TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual
The manifold pressure is controlled by a reg- ulator built into the gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1)Make sure the valve is in the "OFF" position.
2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver.
3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.
4)Light the pilot and turn the valve to "ON" position.
5)The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.
6)When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Screw should be snug, but do not over tighten.
10 | Regency CLASSIC |