INSTALLATION
2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for
3)Check for proper draft.
CAUTION:Anyalterationtotheprod- uct that causes sooting or carbon- ing that results in damage is not the responsibility of the manufacturer.
CLEARANCES TO COMBUSTIBLES
The clearances listed below are MINIMUM dis- tances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearanc- es do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the back wall is too close, move the stove until the correct clearance to the back wall is obtained.
This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with the unit) is installed.
OPTIONAL FAN
INSTALLATION
Important: Disconnect the power supply before installation or servic- ing.
For pedestal unit: To install the fan in an installed
For leg unit: remove 7 screws, remove bottom access panel and install fan as- sembly and follow steps 4 to 17.
1)Open pedestal door and remove door cov- er plate by removing 4 screws. See dia- gram 1.
4)Screw the four
5)Push all the fan wires through the hole on the fan assembly. See diagram 2
.
6)Put power cord (shown in diagram 3) through the hole and pull through to front of unit for easier installation of ground wire.
7)Place fan assembly partially in door cover plate hole. See diagram 2.
8)Attach the 2 ground wires (green) to the ground lug as per diagram 2.
Note: Ground lug is located on the bottom
of the fan assembly. See diagram 2.
This appliance may be installed only with the clearances as shown in the situations pic- tured. Do not combine clearances from one type of installation with another in order to achieve closer clearances. Use the minimum clearances shown in the diagrams. Alcove installations are approved, as long as side wall clearances are maintained.
C33-2 Clearances to Combustibles
A | Side Wall to Unit | 10" / 250 mm |
B | Back Wall to Unit | 6" / 150 mm |
E | Side Wall to Unit | 1.5" / 38 mm |
|
| |
|
| |
|
| to Flue Centerline |
C | Back Wall | |
D | Side Wall | 22" / 559 mm |
F | Side Wall | 13" / 330 mm |
Minimum ceiling height is 36" / 914 mm from top of unit.
Diagram 3
9) Lift the fan assembly in through the pedes- tal and up through the cut out as shown in diagrams 3 and 4.
10) Put the insulation gasket on the back of the fan. Line up the keyhole slots with the matching screws and pull back slightly to lock into place. While holding fan assembly in place, tighten screws.
Diagram 1
2)Remove valve cover plate by removing 2
screws.
3) Remove wire from piezo ignitor.
Diagram 4
Diagram 2
Regency CLASSIC | 7 |