Regency C33-LP2, C33-NG2 installation manual Safety Label, Delta, BC, Canada

Page 4

SAFETY LABEL

This is a copy of the label that accompanies each CLASSIC Freestanding Gas Stove - Nat- ural Gas. We have printed a copy of the contents here for your review. The safety label is located on the back panel.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.

FPI Fireplace Products International Ltd.

Delta, BC, Canada

Serial No. 201

Listed: GAS FIRED VENTED ROOM HEATER

Certified for: CANADA and USA Report No. 476-1345-00 (Oct. 1996)

Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003, CAN/CGA-2.17-M91

FACTORY EQUIPPED FOR NATURAL GAS:

Model C33-NG2 Factory Equipped for 0-2000 ft.

Minimum supply pressure

5"

WC/C.E. (1.25Kpa)

Manifold pressure High

3.8"

WC/C.E. (0.94Kpa)

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Orifice size

36

DMS

 

Altitude

0-2000

ft/pi

(0-610 m)

Maximum Input

33,000

BTUH

(9.67Kw/h)

Minimum Input

17,000

BTUH

(4.98Kw/h)

 

 

 

 

HIGH ALTITUDE CONVERTED NATURAL GAS:

Model C33-NG2

Field Convertable for Altitude 2000-4500 ft. (Report No.476-1345-00)

Minimum supply pressure 5"

WC/C.E. (1.25Kpa)

Manifold pressure High

3.8"

WC/C.E. (0.94Kpa)

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Orifice size

38

DMS

 

Altitude

2000-4500 ft/pi

(610-1370m)

Maximum Input

29,000

BTUH

(8.5Kw/h)

Minimum Input

15,300

BTUH

(4.48Kw/h)

 

 

 

 

GAS FIRED VENTED ROOM HEATER

This appliance must be installed in accordance

with local codes, if any; If not, follow:

ANSI Z223.1/CAN 1-B149.

Electrical Supply (115 V, 1.13 A, 60 Hz)

Not for use with solid fuel.

Optional Fan: (Part #490-917)

Minimum Clearances to Combustibles

 

Back wall

 

 

 

Back wall

Sidewall

B

 

Sidewall

Sidewall

 

A

A

E

A - 10" B - 6" E - 1.5"

Minimum ceiling height from top of unit: 36"/914mm

DO NOT REMOVE THIS LABEL

Made in Canada

908-634a

4

Regency CLASSIC C33-2 Freestanding Gas Stove

Image 4
Contents C33 Classic Freestanding Gas Stove To the New Owner Table of Contents Safety Label Delta, BC, CanadaDo not Remove this Label Installation General Safety InformationInstallation Checklist Before YOU StartOptional FAN Installation C33-2 Reference DimensionsClearances to Combustibles C33-2 Clearances to CombustiblesWiring Pedestal AssemblyNot touch hot surfaces Fan Removal LEG Bottom Shield Assembly Optional Outside AIRDraft Hood VentingGAS Pipe Pressure Testing GAS ConnectionSystem Data High ElevationTest for Flue Spillage LOG SET InstallationValve Description Safety Latch Option 1 Remote Control InstallationOption 2 Remote Wall Switch Option 3 Wall Thermostat InstallationWiring Diagram Normal Operating Sounds of GAS AppliancesLighting Procedure Shutdown ProcedureMaintenance Instructions Operating InstructionsTemperatures keep children, clothing Clean. See installationCopy of the Lighting Plate Instructions Severe Burns may result. Due to high surfaceMaintenance Pilot AdjustmentGeneral Vent Maintenance Aeration AdjustmentGlass Replacement LOG ReplacementGOLD-PLATED Doors Installing Valve Removing Valve AssemblyTo remove valve from valve assembly, continue Main Assembly Parts ListDescription Burner & Logs Base Options Regency Classic C33-2 Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information