SAFETY LABEL
This is a copy of the label that accompanies each CLASSIC Freestanding Gas Stove - Nat- ural Gas. We have printed a copy of the contents here for your review. The safety label is located on the back panel.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli- ances individual manual
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Serial No. 201
Listed: GAS FIRED VENTED ROOM HEATER
Certified for: CANADA and USA Report No.
Tested to: ANSI
FACTORY EQUIPPED FOR NATURAL GAS:
Model C33-NG2 Factory Equipped for 0-2000 ft.
Minimum supply pressure | 5" | WC/C.E. (1.25Kpa) | |
Manifold pressure High | 3.8" | WC/C.E. (0.94Kpa) | |
Manifold pressure Low | 1.1" | WC/C.E. (0.27Kpa) | |
Orifice size | 36 | DMS |
|
Altitude | ft/pi | ||
Maximum Input | 33,000 | BTUH | (9.67Kw/h) |
Minimum Input | 17,000 | BTUH | (4.98Kw/h) |
|
|
|
|
HIGH ALTITUDE CONVERTED NATURAL GAS:
Model
Field Convertable for Altitude
Minimum supply pressure 5" | WC/C.E. (1.25Kpa) | ||
Manifold pressure High | 3.8" | WC/C.E. (0.94Kpa) | |
Manifold pressure Low | 1.1" | WC/C.E. (0.27Kpa) | |
Orifice size | 38 | DMS |
|
Altitude | |||
Maximum Input | 29,000 | BTUH | (8.5Kw/h) |
Minimum Input | 15,300 | BTUH | (4.48Kw/h) |
|
|
|
|
GAS FIRED VENTED ROOM HEATER
This appliance must be installed in accordance
with local codes, if any; If not, follow:
ANSI Z223.1/CAN
Electrical Supply (115 V, 1.13 A, 60 Hz)
Not for use with solid fuel.
Optional Fan: (Part
Minimum Clearances to Combustibles
| Back wall |
|
|
| Back wall |
Sidewall | B |
| Sidewall | Sidewall |
|
A | A | E |
A - 10" B - 6" E - 1.5"
Minimum ceiling height from top of unit: 36"/914mm
DO NOT REMOVE THIS LABEL
Made in Canada |
4 | Regency CLASSIC |