Regency C33-LP2, C33-NG2 installation manual Removing Valve Assembly, Installing Valve

Page 18

MAINTENANCE

REMOVING VALVE

ASSEMBLY

1) Shut off gas supply.

2) If optional fan is installed, disconnect pow- er source to stove.

3) Remove access panel.

a) Front panel on pedestal model. See diagram 1.

b) Panel from bottom of leg shield. See diagram 2.

Note: Access panel only has to be loos- ened to be taken out.

8)If optional fan is installed, remove thermo- disc to bracket by removing three (3) phillips

head M5 screws.

9) Remove front cover with Piezo Igniter by removing two (2) sheet metal screws.

10) Loosen four (4) phillips head M5 valve mounting screws from underside of fire- box. Push valve assembly forward on the teardrop slots and drop down. Diagram 3.

16)Remove inlet pipe with pipe wrench. Note orientation of 90o elbow.

17)Remove two (2) phillips head M5 screws on each side of the valve.

18)Remove valve and remove gas out 90o brass fitting. Note orientation of fitting.

INSTALLING VALVE

Diagram 1

Diagram 2

4)Disconnect gas line to stove.

5)Disconnect 3/8" NPT pipe from 90o elbow on valve.

6 ) Disconnect the two (2) switch wires from valve.

7)Remove two (2) orifice bracket screws inside firebox.

Diagram 3

11)Disconnect Piezo wire.

To remove valve from valve assembly, continue.

12)Remove two (2) thermopile wires.

13)Remove thermocouple with a 9 mm (met- ric) wrench.

14)Remove pilot nut with an 11 mm wrench.

15)Remove valve to orifice nut with a 13/16" wrench.

ASSEMBLY

1)To install a new valve assembly, reverse instructions for removing valve. See assembly steps 1-11.

2)Check for leaks and manifold pressure. See Gas Pressure Test instructions.

3)To reinstall valve, reverse instructions for removing valve assembly, steps 12-18.

18

Regency CLASSIC C33-2 Freestanding Gas Stove

Image 18
Contents C33 Classic Freestanding Gas Stove To the New Owner Table of Contents Safety Label Delta, BC, CanadaDo not Remove this Label Installation Checklist InstallationGeneral Safety Information Before YOU StartClearances to Combustibles Optional FAN InstallationC33-2 Reference Dimensions C33-2 Clearances to CombustiblesPedestal Assembly WiringNot touch hot surfaces Fan Removal Draft Hood LEG Bottom Shield AssemblyOptional Outside AIR VentingSystem Data GAS Pipe Pressure TestingGAS Connection High ElevationLOG SET Installation Test for Flue SpillageValve Description Option 2 Remote Wall Switch Safety LatchOption 1 Remote Control Installation Option 3 Wall Thermostat InstallationWiring Diagram Normal Operating Sounds of GAS AppliancesMaintenance Instructions Lighting ProcedureShutdown Procedure Operating InstructionsCopy of the Lighting Plate Instructions Temperatures keep children, clothingClean. See installation Severe Burns may result. Due to high surfaceGeneral Vent Maintenance MaintenancePilot Adjustment Aeration AdjustmentLOG Replacement Glass ReplacementGOLD-PLATED Doors Removing Valve Assembly Installing ValveTo remove valve from valve assembly, continue Parts List Main AssemblyDescription Burner & Logs Base Options Regency Classic C33-2 Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information