Regency C33-NG2, C33-LP2 installation manual Do not Remove this Label

Page 5

SAFETY LABEL

This is a copy of the label that accompanies each CLASSIC Freestanding Gas Stove - Propane. We have printed a copy of the contents here for your review. The safety label is located on the back panel.

NOTE: Regency units are constantly being im- proved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

FPI Fireplace Products International Ltd.

Delta, BC, Canada

Serial No. 200

Listed: GAS FIRED VENTED ROOM HEATER

Certified for: CANADA and USA

Report No. 476-1345-00 (Oct. 1996)

Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003

FACTORY EQUIPPED FOR PROPANE:

Model C33-LP2

Minimum supply pressure 12"

WC/C.E.(2.85Kpa)

Manifold pressure High

11"

WC/C.E.(2.61Kpa)

Manifold pressure Low

2.9"

WC/C.E.(0.72Kpa)

Orifice size

52

DMS

 

Altitude

0-2000 ft/pi

(0-610 m)

Maximum Input

33,000

BTUH

(9.67Kw/h)

Minimum Input

17,000

BTUH

(4.98Kw/h)

GAS FIRED VENTED ROOM HEATER

This appliance must be installed in accordance

with local codes, if any; If not, follow:

ANSI Z223.1/CAN 1-B149.

Electrical Supply (115 V, 1.13 A, 60 Hz)

Not for use with solid fuel.

Optional Fan: (Part #490-917)

Minimum Clearances to Combustibles

 

Back wall

 

 

 

Back wall

Sidewall

B

 

Sidewall

Sidewall

 

A

A

E

A - 10" B - 6" E - 1.5"

Minimum ceiling height from top of unit: 36"/914mm

DO NOT REMOVE THIS LABEL

Made in Canada

908-635a

Regency CLASSIC C33-2 Freestanding Gas Stove

5

Image 5
Contents C33 Classic Freestanding Gas Stove To the New Owner Table of Contents Delta, BC, Canada Safety LabelDo not Remove this Label General Safety Information InstallationInstallation Checklist Before YOU StartC33-2 Reference Dimensions Optional FAN InstallationClearances to Combustibles C33-2 Clearances to CombustiblesNot touch hot surfaces Fan Removal Pedestal AssemblyWiring Optional Outside AIR LEG Bottom Shield AssemblyDraft Hood VentingGAS Connection GAS Pipe Pressure TestingSystem Data High ElevationValve Description LOG SET InstallationTest for Flue Spillage Option 1 Remote Control Installation Safety LatchOption 2 Remote Wall Switch Option 3 Wall Thermostat InstallationNormal Operating Sounds of GAS Appliances Wiring DiagramShutdown Procedure Lighting ProcedureMaintenance Instructions Operating InstructionsClean. See installation Temperatures keep children, clothingCopy of the Lighting Plate Instructions Severe Burns may result. Due to high surfacePilot Adjustment MaintenanceGeneral Vent Maintenance Aeration AdjustmentGOLD-PLATED Doors LOG ReplacementGlass Replacement To remove valve from valve assembly, continue Removing Valve AssemblyInstalling Valve Description Parts ListMain Assembly Burner & Logs Base Options Regency Classic C33-2 Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information