Regency P48-1 installation manual Installation Procedures, For Regency Direct Vent System Flex

Page 22

INSTALLATION

INSTALLATION

PROCEDURES

for Regency Direct Vent

System (Flex)

1)Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left. Locate the centerline of the termination and mark wall according- ly. Cut a 11"(279mm) hole in the wall (inside dimension).

Note: A top clearance of 2-1/2"(64mm) and side & bottom clearance of

1-1/2"(38mm) must be maintained except that only a 1" (25mm) clear- ance is needed at the termination end. We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give struc- tural rigidity for mounting the ter- mination.

Note: To make the installation more aesthetically pleas- ing, we recom- mend framing out a square to mount the terminal to.

Note: If installing termination on a siding covered wall, furring strips must be used to ensure that the termi- nation is not recessed into the siding.

2)Level the fireplace and fasten it to the framing using nails or screws through the nailing strips.

3)Assemble the vent assembly by applying Mill Pac to the 5"(127mm) inner collar of the termination and slipping the 5"(127mm) liner over it at least 1-3/8" (35mm). Fasten with the 3 screws (drilling pilot holes will make this easier). Apply Mill Pac or high temper- ature silicone to the 8"(203mm) flex pipe and slip it over the 8" outer collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 screws.

NOTE: Horizontal sections must be sup- ported at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner).

4)Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls. The liners must slip over the collars a minimum of 1-3/8".

5)Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap that show which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.

6)Pull the centre 5"(127mm) liner and outer 8"(203mm) liner out enough to slip over the flue collars of the fireplace. (You may wish to cut the liner shorter to make it more workable.) Do not bend liner more than 90o.

7)Apply Mill Pac over the fireplace inner collar and slip the 5"(127mm) liner down over it and attach with 3 supplied screws.

8)Do the same with the 8"(203mm) liner.

9)Apply a bead of silicone between the thim- ble and termination and around the outer edge of the terminal at the wall in order to keep the water out.

IMPORTANT: Do not locate termination hood where excessive snow or ice build- up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

ASTROCAP XL

DIMENSIONS

22

Regency P48-1 Zero Clearance Direct Vent Gas Fireplace

Image 22
Contents P48-1 Gas Fireplace Manufactured Mobile Home Requirements To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P48-NG1 and P48-LP1Installation Checklist InstallationGeneral Safety Information Save These InstructionsOptional Duct System Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Heat ReleaseCeiling ClearancesMantel Max. Depth 36 914mmMantels Mantel LEG ClearancesFraming & Finishing Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsExterior Vent Termination Venting Regency Direct Vent System Flex Horizontal Terminations OnlyDescription Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Parts not supplied by Dura-VentVenting Arrangements Horizontal Terminations Regency Direct Vent System FlexHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Min Max Min Max Min MaxVertical Venting with Three 3 90o Elbows Option + H1 V +Venting Arrangements Vertical Terminations Simpson DURA-VENT Direct Vent GS SystemInstallation Horizontal Installations Offset Chart Vertical TerminationInstallation Procedures For Regency Direct Vent System FlexGAS Pipe Pressure Testing GAS Line InstallationPilot Adjustment High ElevationBrick Panels Installation Bottom ClipsLOG SET Installation 02-88 02-90 02-87 02-89 02-86 02-85 02-84 02-8302-88 02-83 02-86 02-85 02-89 02-84 02-87 02-88 02-8502-83 02-8902-90 02-8602-84Flush Louvers Standard Flush DoorNot under the gas line BAY Louvers Optional BAY DoorOptional Bay Trim Optional Finishing Trim Double Screen DoorOption Remote Control Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesShut the power off Installing the Optional FANTo Remove the Fan Conversion Kit Contains Operating Instructions Normal Operating Sounds GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Bay Glass Replacement Installing ValveDoor Glass Removing Valve Shut off the gas supplyParts List P48-1 Main Assembly102 100 P48-1 Burner & LOG Assembly P48-1 Flush Door & Louvers P48-1 BAY Front & Louvers Regency P48-1 Zero Clearance Direct Vent Gas Fireplace Regency P48-1 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information

P48-1 specifications

The Regency P48-1 is a prominent model in the realm of modern communication technology, particularly recognized for its innovative features and robust performance. Originally launched as part of a series targeting both casual and professional users, the P48-1 stands out through its unique integration of advanced functionalities and user-friendly design.

One of the main features of the Regency P48-1 is its seamless connectivity capabilities. It supports various communication protocols, including Wi-Fi, Bluetooth, and cellular networks, allowing users to maintain reliable connections irrespective of their location. This versatility makes it an ideal choice for individuals who prioritize mobility without sacrificing functionality.

The device is equipped with a high-resolution display that enhances user experience, whether for browsing, video calls, or multimedia content consumption. The touch interface is responsive and intuitive, contributing to easy navigation through different applications and settings. The display’s vivid colors and sharp contrasts make it suitable for extended use, reducing eye strain during prolonged sessions.

At the heart of the Regency P48-1 is its state-of-the-art processing unit, which ensures fast and efficient performance. This technology allows for multitasking capabilities, enabling users to run multiple applications simultaneously without encountering lags. Coupled with significant internal storage and expandable memory options, the device caters to users who require ample space for their data, applications, and media files.

The P48-1 also incorporates advanced battery management technologies, providing extended usage time on a single charge. Users can enjoy the device's capabilities throughout the day without frequent interruptions for recharging. The battery's longevity, combined with fast-charging features, ensures that users remain connected and productive.

Security is a top priority in the design of the Regency P48-1. It includes biometric authentication methods such as fingerprint scanning and facial recognition, offering users peace of mind regarding their private information. Coupled with regular software updates, these features enhance the device's resilience against cybersecurity threats.

In conclusion, the Regency P48-1 embodies a blend of functionality, performance, and user-centric design. Its advanced communication features, high-resolution display, powerful processing capabilities, and robust security measures make it an exemplary device for a wide array of users, from professionals to tech enthusiasts. As technology continues to evolve, the P48-1 serves as a benchmark for what modern communication devices can achieve.