Regency P48-1 High Elevation, GAS Line Installation, Pilot Adjustment, GAS Pipe Pressure Testing

Page 23

INSTALLATION

P48-NG1 System Data

For 0 to 4500 feet altitude

Burner Inlet Orifice Sizes: #27

Max. Input Rating

51,000 Btu/h

Min. Input Rating

29,000 Btu/h

 

 

Supply Pressure

min.5.0" w.c.

 

 

Manifold Pressure

 

(High)

3.8"+/- 0.2"w.c.

Log Set: Ceramic fibre, 8 per set.

Vent System: Simpson Dura-Vent Direct Vent System, Regency Flex Kit

P48-LP1 System Data

Conversion Kit# 370-969

For 0 to 4500 feet altitude

Burner Inlet Orifice Sizes: #47

Max. Input Rating 48,000 Btu/h

Min. Input Rating 26,000 Btu/h

Supply Pressure min.12.0" w.c.

Manifold Pressure

(High)

11"+/- 0.2" w.c.

Log Set: Ceramic fibre, 8 per set.

Vent System: Simpson Dura-Vent Direct Vent System, Regency Flex Kit

HIGH ELEVATION

This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1 2.17-M91).

GAS LINE

INSTALLATION

The gas line can be brought through either the right, the left side or the bottom of the appliance. The gas valve is situated on the bottom of the unit.

For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.

When using copper or flex connectors use only approved fittings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement.

Important: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.

PILOT ADJUSTMENT

Periodically check the pilot flames. Cor- rect flame pattern has three strong blue flames: 1 flowing around the thermopile, 1 around the thermocouple and 1 flowing across the burner (it does not have to be touching the burner).

Note: If you have an incorrect flame pat- tern, contact your Regency dealer for further instructions.

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear burner or thermopile or thermocouple.

The manifold pressure is controlled by a regu- lator built into the gas control, and should be checked at the pressure test point.

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" position.

2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.

6)When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten.

S.I.T. VALVE DESCRIPTION

1)Gas cock knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection - option

5)Outlet Pressure Tap

6)Inlet Pressure Tap

7)Pilot Outlet

8)Main Gas Outlet

9)Alternative TC Connection Point

The gas line connection may be made of rigid pipe, copper pipe or an approved flex connec- tor. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.

GAS PIPE PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pres- sures over 1/2 psig.

Regency P48-1 Zero Clearance Direct Vent Gas Fireplace

23

Image 23 Contents
P48-1 Gas Fireplace To the New Owner Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal for P48-NG1 and P48-LP1 Safety LabelSave These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Duct SystemMax. Depth 36 914mm ClearancesMantel CeilingMantel LEG Clearances MantelsFraming & Finishing Top Facing Support Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionExterior Vent Termination Regency Direct Vent System Flex Horizontal Terminations Only VentingParts not supplied by Dura-Vent Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List DescriptionRegency Direct Vent System Flex Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsMin Max Min Max Min Max Vertical Venting with Two 2 90o ElbowsOption + H1 V + Vertical Venting with Three 3 90o ElbowsSimpson DURA-VENT Direct Vent GS System Venting Arrangements Vertical Terminations Installation Horizontal Installations Vertical Termination Offset ChartFor Regency Direct Vent System Flex Installation ProceduresHigh Elevation GAS Line InstallationPilot Adjustment GAS Pipe Pressure TestingBottom Clips Brick Panels Installation02-88 02-90 02-87 02-89 02-86 02-85 02-84 02-83 LOG SET Installation02-88 02-83 02-86 02-85 02-89 02-84 02-8902-90 02-8602-84 02-87 02-88 02-8502-83Not under the gas line Standard Flush DoorFlush Louvers Optional Bay Trim Optional BAY DoorBAY Louvers Double Screen Door Optional Finishing TrimThermostat Wire Table Option Remote ControlDo not cut the ground terminal off under any circumstances Wiring DiagramTo Remove the Fan Installing the Optional FANShut the power off Conversion Kit Contains Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds GAS AppliancesMaintenance Door Glass Installing ValveBay Glass Replacement Shut off the gas supply Removing ValveP48-1 Main Assembly Parts List102 100 P48-1 Burner & LOG Assembly P48-1 Flush Door & Louvers P48-1 BAY Front & Louvers Regency P48-1 Zero Clearance Direct Vent Gas Fireplace Regency P48-1 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information