Lopi 028-S-75-2 owner manual Chimney Connector Requirements

Page 11

Stove Installation (for qualified installers only)

11

Chimney Connector Requirements

Chimney connector is required from the flue collar of the stove to the factory-built chimney (see Figure 7) or masonry chimney (see Figures 13, 14, and 15).

The chimney connector must be 6” diameter and a minimum 24 gauge black steel, 26 gauge blued steel, or one of the reduced-clearance connectors listed on page 8.

NOTE: Aluminum or galvanized steel is not allowed – these materials can not withstand the flue temperatures and may give off toxic fumes when heated.

NOTE: Standard residential installations may use single-wall connector (Mobile-Homes may not).

The chimney connector may not pass through a ceiling, attic, roof, closet, or any other concealed space (use listed UL 103 HT chimney – see “Chimney Requirements for details). DO NOT USE CONNECTOR PIPE AS CHIMNEY.

The chimney connector should be as short and direct as possible. No more than 180o of elbows (two 90o elbows, or two 45o & one 90o elbow, etc.) may be used for the entire system (connector and chimney).. Horizontal runs should slope upwards 1/4” per foot and be a maximum 36” long.

The chimney connector must be installed with the crimped end pointing downwards (see Figure 7). This prevents creosote from leaking to the exterior of the pipe.

The chimney connector must be fastened to the stove and each adjoining section (and chimney).

In cases where the chimney connector must be passed through a combustible wall or partition, the following NFPA 211 method may be used if local building codes permit. Check with local authorities before installation to insure all necessary requirements have been met. Figure 6 details a wall pass- through based on the NFPA 211 standard.

NFPA 211 Wall Pass-Through

(see NFPA 211 for a full description)

Brick

Fire Clay Thimble

12” Min.

12” Min.

Combustible Materials

Figure 6

© Travis Industries

100-01177

4060802

Image 11
Contents Leyden Wood Stove Save Your Bill of Sale 2IntroductionIntroduction Important InformationTable of Contents Ashes Safety PrecautionsMobile Travis Industries, Inc. grants no warranty, implied orDimensions Features & SpecificationsInstallation Options Features Heating SpecificationsInstallation Type Considerations Planning The InstallationPreparation for Installation Stove Installation ConsiderationsClearances Stove Placement RequirementsFloor Protection Requirements Top View Corner Installation Top View Straight InstallationRear Vent Configuration Bypass Handle InstallationChimney Connector Requirements Performance Chimney RequirementsDrafting Outside Air Requirements Chimney Termination RequirementsMinimum Clearance Combustible See below Alcove Alcove Installation RequirementsMobile Home Requirements Cathedral Ceiling with a Factory Built Chimney Standard Ceiling with a Factory Built ChimneyHearth Stove Direct Connection Hearth Stove Positive ConnectionInterior or Exterior Masonry Chimney Before Your First Fire Safety NoticeOperating Your Appliance Opening the Doors Loading Lid Operation Bypass OperationStarting a Top-Down Fire Starting a FireApproximate Air Control Settings Adjusting the Burn RateAshpan Removal Ash RemovalNormal Operating Sounds Blower OperationRe-Loading the Stove Overnight BurnWood Cutting and Storage Why Dry Wood is KeyHints for Burning Selecting WoodBurn Procedure Pictorial Overview Operating Your Appliance Troubleshooting Remove Ash if necessary Daily Maintenance while stove is in useClean the Glass if necessary Maintaining Your ApplianceCreosote Formation and Need for Removal Monthly Maintenance while appliance is in useDoor and Glass Inspection Touch Up Paint Yearly MaintenanceClean the Combustion Brick Cleaning the Air Duct and Blower if applicableCleaning the Combustor Area Adjusting the Bypass LatchAdjusting the Ashpan Latch Replacing the Loading Lid Gasket DoorReplacing the Glass Replacing the Door GasketFirebox Parts Brick Removal & ReplacementCombustor Removal & Replacement Years 4 & 5 Coverage Parts & Labor Limited 5 Year WarrantyYear1 Coverage Parts & Labor Years 2 & 3 Coverage Parts & LaborConditions & Exclusions Listing Label Listing LabelOptional Equipment Rear Blower InstallationIndex

028-S-75-2 specifications

The Lopi 028-S-75-2 is an innovative and efficient heating solution, designed to provide optimal warmth and comfort in various residential settings. This advanced model stands out due to its superb energy efficiency, making it an ideal choice for homeowners seeking environmentally-friendly heating options without compromising on performance.

One of the main features of the Lopi 028-S-75-2 is its exceptional heating capacity. This unit is engineered to deliver an impressive output, ensuring that even larger spaces can be effectively heated. Its high BTU (British Thermal Unit) output means that the Lopi 028-S-75-2 can quickly warm up a room, making it a reliable option during the colder months.

The technology behind this model incorporates advanced catalytic combustion systems, which enhance efficiency by promoting the complete burning of fuel. This results in reduced emissions, making it a more eco-conscious choice. The inclusion of secondary combustion technology further maximizes heat production, ensuring that more energy is extracted from the fuel used.

Another characteristic that makes the Lopi 028-S-75-2 a standout is its build quality. Constructed from robust materials, this unit is designed to withstand the rigors of daily use while maintaining aesthetic appeal. Its sleek design suits a variety of home interiors, allowing it to blend seamlessly into any décor.

Ease of use is a significant consideration in the design of the Lopi 028-S-75-2. The unit features an intuitive control panel, ensuring straightforward operation. Users can easily adjust settings to match their specific heating needs, providing flexibility and convenience.

Safety features are also a priority with the Lopi 028-S-75-2. It is equipped with built-in safeguards to prevent overheating and ensure safe operation. This gives homeowners peace of mind, knowing that they have a reliable and secure heating source.

Overall, the Lopi 028-S-75-2 combines efficiency, advanced technology, and user-friendly features, making it an excellent choice for anyone looking to invest in a quality heating solution. Whether used in a cozy living room or a spacious family area, this model promises to deliver consistent warmth throughout the winter. Its commitment to performance and sustainability sets it apart in the competitive market of home heating systems.