Lopi 028-S-75-2 owner manual Optional Equipment, Rear Blower Installation

Page 39

39

Optional Equipment

Rear Blower Installation (Part # 99000138)

The rear blower improves heat transfer by pushing heated air through the convection channel. Operating instructions are described in the section "Blower Operation".

a

1-1/2”

c

Bend the legs of the

thermodisk bracket to make it 1-1/2” deep.

b

Tuck the thermodisk into place. It wedges between the rear heat sheild and the cast iron firebox.

Route the wires on the outside of the stove, behind the convection jacket.

d

Route the wires from the blower through the hole in the back of the blower housing. Attach these wires to the thermodisk wires.

3/8" Wrench

f

Attach the blower to the stove with the three screws included with the blower.

e

Position the blower near the rear of the stove. Tuck all excess wire into the blower box, making sure it does not contact any moving parts. Make sure when installing the blower, these wires do not become loose.

g

Plug the blower in. Do not route the power cord under or over the stove or in a

 

 

location where it may become damaged.

 

 

 

 

© Travis Industries

100-01177

4060802

Image 39
Contents Leyden Wood Stove Save Your Bill of Sale 2IntroductionIntroduction Important InformationTable of Contents Ashes Safety PrecautionsMobile Travis Industries, Inc. grants no warranty, implied orDimensions Features & SpecificationsInstallation Options Features Heating SpecificationsInstallation Type Considerations Planning The InstallationPreparation for Installation Stove Installation ConsiderationsStove Placement Requirements Floor Protection RequirementsClearances Top View Corner Installation Top View Straight InstallationRear Vent Configuration Bypass Handle InstallationChimney Connector Requirements Chimney Requirements DraftingPerformance Outside Air Requirements Chimney Termination RequirementsMinimum Clearance Combustible See below Alcove Alcove Installation RequirementsMobile Home Requirements Cathedral Ceiling with a Factory Built Chimney Standard Ceiling with a Factory Built ChimneyHearth Stove Direct Connection Hearth Stove Positive ConnectionInterior or Exterior Masonry Chimney Safety Notice Operating Your ApplianceBefore Your First Fire Opening the Doors Loading Lid Operation Bypass OperationStarting a Top-Down Fire Starting a FireApproximate Air Control Settings Adjusting the Burn RateAshpan Removal Ash RemovalNormal Operating Sounds Blower OperationRe-Loading the Stove Overnight BurnWood Cutting and Storage Why Dry Wood is KeyHints for Burning Selecting WoodBurn Procedure Pictorial Overview Operating Your Appliance Troubleshooting Remove Ash if necessary Daily Maintenance while stove is in useClean the Glass if necessary Maintaining Your ApplianceMonthly Maintenance while appliance is in use Door and Glass InspectionCreosote Formation and Need for Removal Touch Up Paint Yearly MaintenanceClean the Combustion Brick Cleaning the Air Duct and Blower if applicableAdjusting the Bypass Latch Adjusting the Ashpan LatchCleaning the Combustor Area Replacing the Loading Lid Gasket DoorReplacing the Glass Replacing the Door GasketBrick Removal & Replacement Combustor Removal & ReplacementFirebox Parts Years 4 & 5 Coverage Parts & Labor Limited 5 Year WarrantyYear1 Coverage Parts & Labor Years 2 & 3 Coverage Parts & LaborConditions & Exclusions Listing Label Listing LabelOptional Equipment Rear Blower InstallationIndex

028-S-75-2 specifications

The Lopi 028-S-75-2 is an innovative and efficient heating solution, designed to provide optimal warmth and comfort in various residential settings. This advanced model stands out due to its superb energy efficiency, making it an ideal choice for homeowners seeking environmentally-friendly heating options without compromising on performance.

One of the main features of the Lopi 028-S-75-2 is its exceptional heating capacity. This unit is engineered to deliver an impressive output, ensuring that even larger spaces can be effectively heated. Its high BTU (British Thermal Unit) output means that the Lopi 028-S-75-2 can quickly warm up a room, making it a reliable option during the colder months.

The technology behind this model incorporates advanced catalytic combustion systems, which enhance efficiency by promoting the complete burning of fuel. This results in reduced emissions, making it a more eco-conscious choice. The inclusion of secondary combustion technology further maximizes heat production, ensuring that more energy is extracted from the fuel used.

Another characteristic that makes the Lopi 028-S-75-2 a standout is its build quality. Constructed from robust materials, this unit is designed to withstand the rigors of daily use while maintaining aesthetic appeal. Its sleek design suits a variety of home interiors, allowing it to blend seamlessly into any décor.

Ease of use is a significant consideration in the design of the Lopi 028-S-75-2. The unit features an intuitive control panel, ensuring straightforward operation. Users can easily adjust settings to match their specific heating needs, providing flexibility and convenience.

Safety features are also a priority with the Lopi 028-S-75-2. It is equipped with built-in safeguards to prevent overheating and ensure safe operation. This gives homeowners peace of mind, knowing that they have a reliable and secure heating source.

Overall, the Lopi 028-S-75-2 combines efficiency, advanced technology, and user-friendly features, making it an excellent choice for anyone looking to invest in a quality heating solution. Whether used in a cozy living room or a spacious family area, this model promises to deliver consistent warmth throughout the winter. Its commitment to performance and sustainability sets it apart in the competitive market of home heating systems.