Lopi 028-S-75-2 owner manual Hearth Stove Positive Connection, Hearth Stove Direct Connection

Page 17

Stove Installation (for qualified installers only)

17

Hearth Stove

Positive

Connection

NOTE:

Most factory-built chimney manufacturers make stainless steel chimney liners, either flexible or rigid. This provides a wide variety of installation options. Make sure to follow the manufacturer's instructions for installation and support

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cap and flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

prevents water from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: The entire fireplace and

 

 

 

 

 

 

 

 

 

 

 

 

entering

 

 

 

 

chimney must be clean, undamaged,

 

 

 

 

 

 

 

 

 

 

 

 

 

and meet all local building codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(UBC, etc.). Damage must be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

repaired prior to installation. The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chimney must be 15' to 33' tall.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The liner must be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stainless steel connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or flexible vent. Follow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the liner manufacturer's

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

instructions for installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. 36"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airtight Insulated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean-Out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove damper

Floor Protection

or wire it open

 

(See the section

 

"Floor Protection

See the section

Requirements"

"Stove Placement

for more details)

Requirements" for

 

minimum clearances

 

required.

Figure 15

Hearth Stove Direct Connection

NOTE:

Direct connections require installation of an airtight, non-combustible block-off plate or damper adapter.

NOTE: The chimney must have a clay tile liner. If it does not, the installation must use a positive connection (full reline). The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall.

Combustible Mantle

Min. 36"

Floor Protection

(See the section "Floor Protection Requirements" for more details)

Clay

Liner

Stainless steel chimney connector must Extend 1' past the block-off plate or to the flue liner

Airtight

Insulated

Clean-Out

Remove damper or wire it open

Block-off plate or damper adapter

See the section "Stove Placement Requirements" for minimum clearances required.

Figure 16

© Travis Industries

100-01177

4060802

Image 17
Contents Leyden Wood Stove Introduction 2IntroductionImportant Information Save Your Bill of SaleTable of Contents Ashes Safety PrecautionsMobile Travis Industries, Inc. grants no warranty, implied orInstallation Options Features Features & SpecificationsHeating Specifications DimensionsPreparation for Installation Planning The InstallationStove Installation Considerations Installation Type ConsiderationsClearances Stove Placement RequirementsFloor Protection Requirements Top View Corner Installation Top View Straight InstallationRear Vent Configuration Bypass Handle InstallationChimney Connector Requirements Performance Chimney RequirementsDrafting Outside Air Requirements Chimney Termination RequirementsMinimum Clearance Combustible See below Alcove Alcove Installation RequirementsMobile Home Requirements Cathedral Ceiling with a Factory Built Chimney Standard Ceiling with a Factory Built ChimneyHearth Stove Direct Connection Hearth Stove Positive ConnectionInterior or Exterior Masonry Chimney Before Your First Fire Safety NoticeOperating Your Appliance Opening the Doors Loading Lid Operation Bypass OperationStarting a Top-Down Fire Starting a FireApproximate Air Control Settings Adjusting the Burn RateAshpan Removal Ash RemovalRe-Loading the Stove Blower OperationOvernight Burn Normal Operating SoundsHints for Burning Why Dry Wood is KeySelecting Wood Wood Cutting and StorageBurn Procedure Pictorial Overview Operating Your Appliance Troubleshooting Clean the Glass if necessary Daily Maintenance while stove is in useMaintaining Your Appliance Remove Ash if necessaryCreosote Formation and Need for Removal Monthly Maintenance while appliance is in useDoor and Glass Inspection Clean the Combustion Brick Yearly MaintenanceCleaning the Air Duct and Blower if applicable Touch Up PaintCleaning the Combustor Area Adjusting the Bypass LatchAdjusting the Ashpan Latch Replacing the Glass DoorReplacing the Door Gasket Replacing the Loading Lid GasketFirebox Parts Brick Removal & ReplacementCombustor Removal & Replacement Year1 Coverage Parts & Labor Limited 5 Year WarrantyYears 2 & 3 Coverage Parts & Labor Years 4 & 5 Coverage Parts & LaborConditions & Exclusions Listing Label Listing LabelOptional Equipment Rear Blower InstallationIndex

028-S-75-2 specifications

The Lopi 028-S-75-2 is an innovative and efficient heating solution, designed to provide optimal warmth and comfort in various residential settings. This advanced model stands out due to its superb energy efficiency, making it an ideal choice for homeowners seeking environmentally-friendly heating options without compromising on performance.

One of the main features of the Lopi 028-S-75-2 is its exceptional heating capacity. This unit is engineered to deliver an impressive output, ensuring that even larger spaces can be effectively heated. Its high BTU (British Thermal Unit) output means that the Lopi 028-S-75-2 can quickly warm up a room, making it a reliable option during the colder months.

The technology behind this model incorporates advanced catalytic combustion systems, which enhance efficiency by promoting the complete burning of fuel. This results in reduced emissions, making it a more eco-conscious choice. The inclusion of secondary combustion technology further maximizes heat production, ensuring that more energy is extracted from the fuel used.

Another characteristic that makes the Lopi 028-S-75-2 a standout is its build quality. Constructed from robust materials, this unit is designed to withstand the rigors of daily use while maintaining aesthetic appeal. Its sleek design suits a variety of home interiors, allowing it to blend seamlessly into any décor.

Ease of use is a significant consideration in the design of the Lopi 028-S-75-2. The unit features an intuitive control panel, ensuring straightforward operation. Users can easily adjust settings to match their specific heating needs, providing flexibility and convenience.

Safety features are also a priority with the Lopi 028-S-75-2. It is equipped with built-in safeguards to prevent overheating and ensure safe operation. This gives homeowners peace of mind, knowing that they have a reliable and secure heating source.

Overall, the Lopi 028-S-75-2 combines efficiency, advanced technology, and user-friendly features, making it an excellent choice for anyone looking to invest in a quality heating solution. Whether used in a cozy living room or a spacious family area, this model promises to deliver consistent warmth throughout the winter. Its commitment to performance and sustainability sets it apart in the competitive market of home heating systems.