Lopi 028-S-75-2 owner manual Standard Ceiling with a Factory Built Chimney

Page 16

16

Stove Installation (for qualified installers only)

Standard Ceiling with a Factory Built Chimney

Chimney Cap (See the section "Chimney

Termination Requirements" for more

Chimney Sections

 

}

Insulation

}

Follow the chimney

 

 

 

manufacturer's instructions

 

 

and clearances for floor

 

 

penetrations. A ceiling

 

 

support is required, an attic

 

 

insulation shield is required

 

 

where insulation is present.

 

 

Chimney Connector Sections

 

Floor Protection

(See the section "Floor Protection Requirements" for more details)

Follow the chimney manufacturer's instructions and clearances for roof penetrations. A storm collar and flashing are required (some require a radiation shield).

Minimum Air Space to Combustibles (See Chimney Manufacturer's Instructions - usually 2")

Minimum 15'

Maximum 33'

Stove Clearances (See the section "Stove Placement Requirements" for more details)

Figure 13

Cathedral Ceiling with a Factory Built Chimney

Chimney Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(See the section "Chimney

 

 

 

 

 

 

 

 

 

 

 

 

Termination Requirements"

 

 

 

 

 

}

 

 

 

for more details)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow the chimney

Chimney Sections

 

 

 

 

 

 

 

 

 

manufacturer's instructions

 

 

 

 

 

 

 

 

 

and clearances for roof

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

penetrations. A storm

Minimum Air Space to

 

 

 

 

 

collar, flashing, and

Combustibles (See Chimney

 

 

 

 

 

 

 

 

 

 

cathedral-style chimney

 

 

 

 

 

 

 

 

 

Manufacturer's Instructions -

 

 

 

 

 

 

 

 

 

 

support are required

usually 2")

 

 

 

 

 

 

 

 

 

 

(some require a radiation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shield).

 

 

Chimney

 

 

 

 

 

 

 

 

 

 

Minimum 15'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum 33'

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sections

 

 

 

 

 

 

 

 

 

 

 

Floor Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove Clearances

(See the section "Floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(See the section "Stove

Protection Requirements"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Placement Requirements"

for more details)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for more details)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 14

© Travis Industries

100-01177

4060802

Image 16
Contents Leyden Wood Stove 2Introduction IntroductionImportant Information Save Your Bill of SaleTable of Contents Safety Precautions AshesTravis Industries, Inc. grants no warranty, implied or MobileFeatures & Specifications Installation Options FeaturesHeating Specifications DimensionsPlanning The Installation Preparation for InstallationStove Installation Considerations Installation Type ConsiderationsFloor Protection Requirements Stove Placement RequirementsClearances Top View Straight Installation Top View Corner InstallationBypass Handle Installation Rear Vent ConfigurationChimney Connector Requirements Drafting Chimney RequirementsPerformance Chimney Termination Requirements Outside Air RequirementsAlcove Installation Requirements Minimum Clearance Combustible See below AlcoveMobile Home Requirements Standard Ceiling with a Factory Built Chimney Cathedral Ceiling with a Factory Built ChimneyHearth Stove Positive Connection Hearth Stove Direct ConnectionInterior or Exterior Masonry Chimney Operating Your Appliance Safety NoticeBefore Your First Fire Opening the Doors Bypass Operation Loading Lid OperationStarting a Fire Starting a Top-Down FireAdjusting the Burn Rate Approximate Air Control SettingsAsh Removal Ashpan RemovalBlower Operation Re-Loading the StoveOvernight Burn Normal Operating SoundsWhy Dry Wood is Key Hints for BurningSelecting Wood Wood Cutting and StorageBurn Procedure Pictorial Overview Operating Your Appliance Troubleshooting Daily Maintenance while stove is in use Clean the Glass if necessaryMaintaining Your Appliance Remove Ash if necessaryDoor and Glass Inspection Monthly Maintenance while appliance is in useCreosote Formation and Need for Removal Yearly Maintenance Clean the Combustion BrickCleaning the Air Duct and Blower if applicable Touch Up PaintAdjusting the Ashpan Latch Adjusting the Bypass LatchCleaning the Combustor Area Door Replacing the GlassReplacing the Door Gasket Replacing the Loading Lid GasketCombustor Removal & Replacement Brick Removal & ReplacementFirebox Parts Limited 5 Year Warranty Year1 Coverage Parts & LaborYears 2 & 3 Coverage Parts & Labor Years 4 & 5 Coverage Parts & LaborConditions & Exclusions Listing Label Listing LabelRear Blower Installation Optional EquipmentIndex

028-S-75-2 specifications

The Lopi 028-S-75-2 is an innovative and efficient heating solution, designed to provide optimal warmth and comfort in various residential settings. This advanced model stands out due to its superb energy efficiency, making it an ideal choice for homeowners seeking environmentally-friendly heating options without compromising on performance.

One of the main features of the Lopi 028-S-75-2 is its exceptional heating capacity. This unit is engineered to deliver an impressive output, ensuring that even larger spaces can be effectively heated. Its high BTU (British Thermal Unit) output means that the Lopi 028-S-75-2 can quickly warm up a room, making it a reliable option during the colder months.

The technology behind this model incorporates advanced catalytic combustion systems, which enhance efficiency by promoting the complete burning of fuel. This results in reduced emissions, making it a more eco-conscious choice. The inclusion of secondary combustion technology further maximizes heat production, ensuring that more energy is extracted from the fuel used.

Another characteristic that makes the Lopi 028-S-75-2 a standout is its build quality. Constructed from robust materials, this unit is designed to withstand the rigors of daily use while maintaining aesthetic appeal. Its sleek design suits a variety of home interiors, allowing it to blend seamlessly into any décor.

Ease of use is a significant consideration in the design of the Lopi 028-S-75-2. The unit features an intuitive control panel, ensuring straightforward operation. Users can easily adjust settings to match their specific heating needs, providing flexibility and convenience.

Safety features are also a priority with the Lopi 028-S-75-2. It is equipped with built-in safeguards to prevent overheating and ensure safe operation. This gives homeowners peace of mind, knowing that they have a reliable and secure heating source.

Overall, the Lopi 028-S-75-2 combines efficiency, advanced technology, and user-friendly features, making it an excellent choice for anyone looking to invest in a quality heating solution. Whether used in a cozy living room or a spacious family area, this model promises to deliver consistent warmth throughout the winter. Its commitment to performance and sustainability sets it apart in the competitive market of home heating systems.