Regency P131, P121RC, P121LC installation manual Horizontal Installations

Page 19

INSTALLATION

Vertical Venting with Three (3) 90o Elbows

 

Option

 

V + V1

H + H1

 

A)

2' (610mm) Minimum

3' (914mm) Maximum

 

B)

3' (914mm) Minimum

6' (1.86m) Maximum

 

 

C)

4'

(1.22m) Minimum

9' (2.7m) Maximum

 

D)

5'

(1.5m) Minimum

12' (3.6m) Maximum

 

 

 

 

 

 

With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Diagram 12

HORIZONTAL

INSTALLATIONS

Install the vent system according to the manufacturer's instructions included with the components.

gram 1. Push the pipe sections com- pletely together, then twist-lock one section clockwise approximately one- quarter turn, until the two sections are fully locked. The female locking lugs will not be visible from the outside, on the Black Pipe or fittings. They may be located by examining the inside of the female ends.

1)Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is at- tached. If this is the case, you may want to adjust the location of the unit. Rough in the gas.

2)Direct Vent pipe and fittings are designed with special twist-lock connections to con- nect the venting system to the appliance flue outlet. A twist-lock appliance adaptor is an available option that must be used in con- junction with the Simpson Dura-Vent Direct Vent GS system.

3)Put a bead of silicone inside the outer section of the adapter and a bead of Mill Pac on the inner collar. Slip the adapter over the exist- ing inner and outer flue collar and fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier). Level the fireplace and fasten it to the framing using nails or screws through the nailing strips.

4)Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection.

Note:

a)Twist-lock procedure: Four indentations, located on the female ends of pipes and fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings, by orienting the four pipe inden- tations so they match and slide in to the four entry slots on the male ends, Dia-

Diagram 1

Note: Apply sealant "Mill-Pac" to inner pipe and high temperature sili- cone sealant to outer pipe on eve- ry twist-lock joint.

b)Horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose.

5)Mark the wall for a 10" x 10" square hole. The center of the square hole should line up with the centerline of the horizontal pipe. Cut and frame the 10 inch square hole in the exterior wall where the vent will be termi- nated. If the wall being penetrated is con- structed of non-combustible material, i.e. masonry block or concrete, a 7"(178mm) dia. (7-1/2"(191mm) dia. for flex) hole is acceptable.

Note: With Dura-Vent, the minimum height is achieved by installing a 45o elbow di- rectly to the flue adaptor.

Diagram 2

Note:

a)The horizontal run of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.

b)The location of the horizontal vent ter- mination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. For External Vent Terminal Locations, see diagram on page 12.

6)The arrow on the vent cap should be pointing up. Insure that the 1-1/2" clear- ances to combustible materials are main- tained (Diagram 3 on page 16). Install the termination cap.

The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

Note: If installing termination on a siding covered wall, a vinyl siding stand- off or furring strips must be used

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

19

Image 19
Contents Owners Installation Manual To the New Owner Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal for P121/P121LC/P121RC/P131 Safety LabelSave These Instructions InstallationGeneral Safety Information Installation ChecklistP121-1 See Thru P131-1 Pier SpecificationsP121LC-1 Left Corner Unit P121RC-1 Right Corner Unit Locating Your GAS Fireplace Combustible Mantels ClearancesP121-1 See Thru P131-1 Pier P121LC-1 / P121RC-1 Corner Unit P121-1 See Thru Framing DimensionsFraming and Finishing P121LC-1 Corner Unit P131-1 Pier P121RC-1 Corner UnitVenting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Facing & Finishing RequirementsAir supply outlet VentVenting Arrangement Horizontal Terminations Description Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Simpson Dura-Vent Direct Vent GSOption Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsVenting Arrangements Vertical Terminations Vertical Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsHorizontal Installations Set the gas appliance in its desired location. Drop a Vertical TerminationOffset Chart Installation ProceduresFor Regency AstroCapTM Direct Vent System Flex Installation High Elevation GAS Line InstallationPilot Adjustment GAS Pipe Pressure Testing02-80 02-82 02-79 02-81 LOG Installation02-82 02-81 02-81 02-79 02-82 02-8002-80 P121-1 & P131-1 Corner Models Glass Door RemovalFinishing Trim Louvers & GrillsThermostat Wire Table Remote ControlDo not cut the ground terminal off under any circumstances Wiring DiagramOperating Instructions Do not Remove this Instruction Plate 908-017a Maintenance InstructionsGeneral Vent Maintenance Copy of the Lighting Plate InstructionsMaintenance Installing Valve FAN Replacement P121-1 see Thru Main Assembly Parts ListP131-1 Pier Main Assembly P121RC-1 Right Corner Main Assembly P121LC-1 Left Corner Main Assembly P121/P121LC/P121RC/P131-1 Burner Assembly & LOG SET Warranty Lifetime WarrantyInstaller Please complete the following information
Related manuals
Manual 48 pages 21.81 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.