Regency P121RC, P121LC, P131 installation manual Installing Valve

Page 32

MAINTENANCE

8)Remove the Side Base Brick Panels and finally the Long Base Brick Panels.

Remove Left & Right Side Base

Brick Panels

Remove the 2 Long Base Brick Panels

9)Disconnect the inlet gas line.

10)Disconnect the 2 TP wires and the 2 TH wires from the valve.

11)Remove the 16 Phillips head screws secur- ing the valve tray.

12) Lift the entire assembly out.

13)Undo the pilot tube from the valve with a 7/16" wrench.

14)Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.

15)Remove the Piezo igniter wire and push button assembly.

16)Undo the "gas out" flare nut with a 13/16" wrench.

17)Undo the "gas out" flare fitting with an 11/16" wrench.

18)Remove the 6 Phillips head screws from the sides of the valve bracket and remove valve.

Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.

INSTALLING VALVE

1)Attach the valve to the valve bracket with the 6 (m5x8 metric) screws provided.

2)Reconnect the "gas out" flare fitting with an 11/16" wrench.

3)Reconnect the "gas out" flare nut with a 13/ 16" wrench.

4)Install piezo ignitor push button assembly and reconnect wire.

5)Reconnect the quick drop out thermocouple nut with a 9mm wrench.

6)Reconnect the pilot tube nut with a 7/16" wrench.

7) Scrape off the old gasket from the floor of the firebox and from the valve tray assem- bly.

8)Install a new gasket and reinstall the valve tray assembly.

Note: Failure to install a new gasket may severely affect the appliance perform- ance.

9)Reinstall the 16 hold down screws.

10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

11)Reinstall the Burner Assembly.

13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open flame for leak testing.)

14)Fire up the unit temporarily

15)Check the manifold pressure.

16)Reinstall the logs, grate and brick panels as needed.

17)Reinstall the glass doors.

18)Fire up the unit again and check for proper flame appearance.

32

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

Image 32
Contents Owners Installation Manual Manufactured Mobile Home Requirements To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P121/P121LC/P121RC/P131Installation General Safety InformationInstallation Checklist Save These InstructionsSpecifications P121-1 See Thru P131-1 PierP121LC-1 Left Corner Unit P121RC-1 Right Corner Unit Locating Your GAS Fireplace Clearances Combustible MantelsP121-1 See Thru Framing Dimensions Framing and FinishingP121LC-1 Corner Unit P131-1 Pier P121RC-1 Corner Unit P121-1 See Thru P131-1 Pier P121LC-1 / P121RC-1 Corner UnitUnit Assembly Prior to Installation Top Standoff AssemblyFacing & Finishing Requirements Venting IntroductionVent Air supply outletVenting Arrangement Horizontal Terminations Simpson DURA-VENT Venting Simpson DURA-VENT Venting Components ListSimpson Dura-Vent Direct Vent GS DescriptionVenting Arrangements Horizontal Terminations OptionHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsVenting Arrangements Vertical Terminations Vertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsHorizontal Installations Vertical Termination Set the gas appliance in its desired location. Drop aFor Regency AstroCapTM Direct Vent System Flex Installation ProceduresOffset Chart Installation GAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High ElevationLOG Installation 02-82 02-8102-81 02-79 02-82 02-80 02-80 02-82 02-79 02-8102-80 Glass Door Removal Finishing TrimLouvers & Grills P121-1 & P131-1 Corner ModelsRemote Control Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesOperating Instructions Maintenance Instructions General Vent MaintenanceCopy of the Lighting Plate Instructions Do not Remove this Instruction Plate 908-017aMaintenance Installing Valve FAN Replacement Parts List P121-1 see Thru Main AssemblyP131-1 Pier Main Assembly P121RC-1 Right Corner Main Assembly P121LC-1 Left Corner Main Assembly P121/P121LC/P121RC/P131-1 Burner Assembly & LOG SET Warranty Warranty LifetimeInstaller Please complete the following information
Related manuals
Manual 48 pages 21.81 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.