Regency P121LC, P121RC, P131 Manufactured Mobile Home Requirements, To the New Owner

Page 2

To the New Owner:

Congratulations!

You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P121/ P121LC/P121RC/P131 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model P121/P121LC/P121RC/P131 has been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.

IMPORTANT: If the unit is to be installed into a bathroom, optional Neo ceramic glass Part# 360-946 Front or Part# 360-948 Side must be purchased and installed in place of the tempered glass supplied with the unit.

MANUFACTURED MOBILE HOME REQUIREMENTS

INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE

This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88a-2000/CSA 2.33a-2000 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA 2.17-M91.

This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This Regency mobile/manufactured home listed appliance comes factory equipped with four 1/4" diameter holes located near each corner of the base. Fasten the fireplace in place using screw, inserted through the holes.

This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes. See page 28.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.

This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other cases, unless a certified kit is used.

Ensure that structural members are not cut or weakened during installation.

2

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

Image 2
Contents Owners Installation Manual Manufactured Mobile Home Requirements To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P121/P121LC/P121RC/P131Installation Checklist InstallationGeneral Safety Information Save These InstructionsSpecifications P121-1 See Thru P131-1 PierP121LC-1 Left Corner Unit P121RC-1 Right Corner Unit Locating Your GAS Fireplace Clearances Combustible MantelsP121LC-1 Corner Unit P131-1 Pier P121RC-1 Corner Unit P121-1 See Thru Framing DimensionsFraming and Finishing P121-1 See Thru P131-1 Pier P121LC-1 / P121RC-1 Corner UnitFacing & Finishing Requirements Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionVent Air supply outletVenting Arrangement Horizontal Terminations Simpson Dura-Vent Direct Vent GS Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List DescriptionVenting Arrangements Horizontal Terminations OptionHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsVenting Arrangements Vertical Terminations Vertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsHorizontal Installations Vertical Termination Set the gas appliance in its desired location. Drop aFor Regency AstroCapTM Direct Vent System Flex Installation ProceduresOffset Chart Installation GAS Pipe Pressure Testing GAS Line InstallationPilot Adjustment High Elevation02-81 02-79 02-82 02-80 LOG Installation02-82 02-81 02-80 02-82 02-79 02-8102-80 Louvers & Grills Glass Door RemovalFinishing Trim P121-1 & P131-1 Corner ModelsRemote Control Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesOperating Instructions Copy of the Lighting Plate Instructions Maintenance InstructionsGeneral Vent Maintenance Do not Remove this Instruction Plate 908-017aMaintenance Installing Valve FAN Replacement Parts List P121-1 see Thru Main AssemblyP131-1 Pier Main Assembly P121RC-1 Right Corner Main Assembly P121LC-1 Left Corner Main Assembly P121/P121LC/P121RC/P131-1 Burner Assembly & LOG SET Warranty Warranty LifetimeInstaller Please complete the following information
Related manuals
Manual 48 pages 21.81 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.