Regency P131, P121RC, P121LC installation manual Remote Control, Thermostat Wire Table

Page 27

INSTALLATION

Option 1:

Option 2:

Option 3:

REMOTE CONTROL

WALL SWITCH

WALL THERMOSTAT

Can be used with Option 2 or 3

Can be used with Option 1 or 3

but not both.

but not both.

Can be used with Option 1 or 2 but not both.

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very im- portant). Run wires from the fireplace to that location. Use the Thermostat Wire Ta- ble.

2)Connect the two wires to the gas valve. See diagram below.

CAUTION

Do not connect millivolt remote

control wires to a 120V wire.

1)Run the supplied 15' of wire through the back gas inlet opening. Be careful not to damage wire.

Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.

2)Connect the wire to the supplied wall switch and install into the receptacle box.

CAUTION

Do not connect millivolt

wall switch wire to a 120V wire.

A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use the table below to determine the maximum wire length.

Note: Preferable if the thermostat is in- stalled on an interior wall.

Regency offers an optional programmable ther- mostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not connect millivolt

wall thermostat wires

to a 120V wire.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

 

14 GA.

50 Ft.

 

16 GA.

32 Ft.

 

18 GA.

20 Ft.

 

3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

20 GA.

12 Ft.

22 GA.

9 Ft.

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

27

Image 27
Contents Owners Installation Manual To the New Owner Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal for P121/P121LC/P121RC/P131 Safety LabelSave These Instructions InstallationGeneral Safety Information Installation ChecklistP121-1 See Thru P131-1 Pier SpecificationsP121LC-1 Left Corner Unit P121RC-1 Right Corner Unit Locating Your GAS Fireplace Combustible Mantels ClearancesP121-1 See Thru P131-1 Pier P121LC-1 / P121RC-1 Corner Unit P121-1 See Thru Framing DimensionsFraming and Finishing P121LC-1 Corner Unit P131-1 Pier P121RC-1 Corner UnitVenting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Facing & Finishing RequirementsAir supply outlet VentVenting Arrangement Horizontal Terminations Description Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Simpson Dura-Vent Direct Vent GSOption Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsVenting Arrangements Vertical Terminations Vertical Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsHorizontal Installations Set the gas appliance in its desired location. Drop a Vertical TerminationInstallation Procedures Offset ChartFor Regency AstroCapTM Direct Vent System Flex Installation High Elevation GAS Line InstallationPilot Adjustment GAS Pipe Pressure Testing02-80 02-82 02-79 02-81 LOG Installation02-82 02-81 02-81 02-79 02-82 02-8002-80 P121-1 & P131-1 Corner Models Glass Door RemovalFinishing Trim Louvers & GrillsThermostat Wire Table Remote ControlDo not cut the ground terminal off under any circumstances Wiring DiagramOperating Instructions Do not Remove this Instruction Plate 908-017a Maintenance InstructionsGeneral Vent Maintenance Copy of the Lighting Plate InstructionsMaintenance Installing Valve FAN Replacement P121-1 see Thru Main Assembly Parts ListP131-1 Pier Main Assembly P121RC-1 Right Corner Main Assembly P121LC-1 Left Corner Main Assembly P121/P121LC/P121RC/P131-1 Burner Assembly & LOG SET Warranty Lifetime WarrantyInstaller Please complete the following information
Related manuals
Manual 48 pages 21.81 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.