INSTALLATION

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency® Direct Vent System

These venting systems, in combination with the L900-1, have been tested and listed as a direct vent system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.

FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the L900-1 using a flexible vent.

FPI Kit #

Length

Contains:

#946-615

4 Feet

1)

8” flexible liner (Kit length)

 

 

2)

5” flexible liner (Kit length)

 

 

3)

spring spacers

#946-618

6 Feet

4)

thimble

 

 

5)

AstroCap termination cap

 

 

6)

screws

 

 

7)

tube of Mill Pac

#946-616

10 Feet

 

 

8)

plated screws

 

 

9)

S.S. screws #8 x 1-1/2” drill point

 

 

10)

vinyl siding standoff

 

 

 

 

Notes:

1) Liner sections should be continuous without any joints or seams.

2) Only Flex pipe purchased from FPI may be used for Flex installations.

3) Horizontal vent must be supported every 3 feet.

4) Awall thimble is mandatory for all horizontal terminations due to high temperatures.

INSTALLATION

Regency® L900-1 Direct Vent Gas Fireplace

15

Image 15
Contents Liberty L900-1 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Duct KIT Heat Release KIT Finished FloorClearances Mantel LEG Clearances Mantel ClearancesNON-COMBUSTIBLE Requirements Framing & Finishing Unit Assembly Prior to Installation Finishing Template Venting Introduction Vent Restrictor Position Minimum Clearance Requirements Exterior Vent Termination RequirementsHorizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart Installation Allowable Horizontal Terminations Vent Restrictor SettingHorizontal Venting with Two 2 90o Elbows Installation Allowable Vertical Terminations Unit Installation with Horizontal Termination Minimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Unit InstallationHigh Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingWiring Diagram Aeration AdjustmentLatch Location Grate Conversion KIT #547-969 from NG to LPLP Conversion Kit Contains Qty Description HingeDoorBurner Orifi ce Handle with care. do not Force Into Position Brick Panel InstallationFor L676-1 Units only Top Brick Panel Right SideL900-1 Left Side Brick Panel Back Brick PanelLOG SET Installation Log kit # 547-930 contains the following pieces DescriptionVermiculite 3rd Grate Post Installation1st Grate Post Completed Log Set Installation Outer Most Bracket Hole Mesh Pull Screen InstallationLeft Side Rod Right Side Rod Inner Most Bracket HoleReplace Log G Optional Andiron InstallationFinal Installation L900-1 Log GOperating Instructions Lighting Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Copy of Lighting Plate InstructionsMaintenance DC Spark BOX Battery Replacement DC Spark BOX ReplacementDC Spark Box Rear Log Stand HingeDoor Valve Tray ReplacementCheck operation of flame control Valve TrayMain Assembly Parts ListParts List Burner & LOG Assembly Warranty Limited Lifetime WarrantyInstaller Please complete the following information