Regency L900-1 installation manual Table of Contents

Page 3

TABLE OF CONTENTS

SAFETY LABEL

 

Copy of Safety Decal

4

REQUIREMENTS

 

MA Code - CO Detector

5

UNIT DIMENSIONS

 

Unit Dimensions

6

with Flex Vent System

25

High Elevation

26

Gas Line Installation

26

Pilot Adjustment

26

Gas Pipe Pressure Testing

26

SIT 829 Valve Description

26

Aeration Adjustment

27

Wiring Diagram

27

Conversion from NG to LP

28

Brick Panel Installation

30

Log Set Installation

32

Mesh Pull Screen Installation

36

Optional Andiron Installation

37

INSTALLATION

 

Important Message

7

Before You Start

7

General Safety Information

7

Installation Checklist

7

Manufactured Mobile Home Additional Requirements ..

8

Locating Your Gas Fireplace

8

Heatwave Duct Kit

8

Heat Release Kit

8

Finished Floor

8

Clearances

9

Mantel Clearances

10

Mantel Leg Clearances

10

Framing & Finishing

11

Unit Assembly Prior To Installation

12

Top Standoff Assembly

12

Side Nailing Strips

12

Finishing Template

12

Venting Introduction

12

Vent Restrictor Position

13

Exterior Vent Termination Requirements

14

Venting Arrangements

15

Horizontal Termination (Flex)

15

Rigid Pipe Venting Systems

16

Basic Horizontal & Vertical Terminations

16

5” x 8” Rigid Pipe Cross Reference Chart

17

Venting Arrangements

19

Allowable Horizontal Terminations

19

Venting Arrangements

22

Allowable Vertical Terminations

22

Unit Installation with Horizontal Termination

23

Unit Installation with Vertical Termination

24

Unit Installation

25

Horizontal Termination

25

OPERATING INSTRUCTIONS

 

Operating Instructions

38

Matching Remote Control & Receiver Code

38

Lighting Procedure

38

Shutdown Procedure

38

First Fire

38

Normal Operating Sounds of Gas Appliances

39

Copy of Lighting Plate Instructions

39

MAINTENANCE

 

Maintenance Instructions

40

General Vent Maintenance

40

Log Replacement

40

Thermopile / Thermocouple

40

Glass Gasket

40

Door Glass

40

Glass Replacement

40

DC Spark Box Battery Replacement

41

DC Spark Box Replacement

41

Valve Tray Replacement

42

PARTS LIST

 

Main Assembly

44

Burner & Log Assembly

46

WARRANTY

 

The Warranty: Limited Lifetime

47

Regency® L900-1 Direct Vent Gas Fireplace

3

Image 3
Contents Liberty L900-1 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Duct KIT Heat Release KIT Finished FloorClearances Mantel LEG Clearances Mantel ClearancesNON-COMBUSTIBLE Requirements Framing & FinishingUnit Assembly Prior to Installation Finishing TemplateVenting Introduction Vent Restrictor Position Minimum Clearance Requirements Exterior Vent Termination RequirementsHorizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart Installation Allowable Horizontal Terminations Vent Restrictor SettingHorizontal Venting with Two 2 90o Elbows Installation Allowable Vertical Terminations Unit Installation with Horizontal Termination Minimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Unit InstallationHigh Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingWiring Diagram Aeration AdjustmentLatch Location Grate Conversion KIT #547-969 from NG to LPLP Conversion Kit Contains Qty Description HingeDoorBurner Orifi ce Handle with care. do not Force Into Position Brick Panel InstallationFor L676-1 Units only Top Brick Panel Right SideL900-1 Left Side Brick Panel Back Brick PanelLOG SET Installation Log kit # 547-930 contains the following pieces DescriptionVermiculite 3rd Grate Post Installation1st Grate Post Completed Log Set Installation Outer Most Bracket Hole Mesh Pull Screen InstallationLeft Side Rod Right Side Rod Inner Most Bracket HoleReplace Log G Optional Andiron InstallationFinal Installation L900-1 Log GOperating Instructions Lighting Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Copy of Lighting Plate InstructionsMaintenance DC Spark BOX Battery Replacement DC Spark BOX ReplacementDC Spark Box Rear Log Stand HingeDoor Valve Tray ReplacementCheck operation of flame control Valve TrayMain Assembly Parts ListParts List Burner & LOG Assembly Warranty Limited Lifetime WarrantyInstaller Please complete the following information

L900-1 specifications

The Regency L900-1 is a remarkable innovation in the realm of radio equipment, designed for enthusiasts and professionals alike. Renowned for its exceptional performance, this model seamlessly integrates a plethora of advanced features, making it a top choice among users.

One of the most notable characteristics of the Regency L900-1 is its outstanding reception capabilities. Equipped with cutting-edge digital signal processing technology, this radio provides crystal-clear audio quality even in congested frequency environments. This technology minimizes noise and interference, ensuring a pristine listening experience. Users will appreciate the enhanced sensitivity and selectivity, allowing them to easily tune into distant stations or weak signals.

The design of the L900-1 is user-friendly, featuring an intuitive interface that simplifies operation. The well-organized control panel includes a large LCD display that provides vital information at a glance, such as frequency, volume levels, and signal strength. The device also includes clearly marked buttons and knobs that are easy to navigate, catering to both beginners and seasoned radio operators.

Another standout feature of the Regency L900-1 is its versatile tuning options. Users can choose between manual tuning, automatic scanning, or preset channels, offering flexibility based on individual preferences. The radio covers a broad frequency range, enabling access to AM, FM, and SW bands, which broadens the spectrum of stations and content available to users.

Additionally, the L900-1 incorporates modern connectivity options. It supports Bluetooth pairing, allowing users to stream audio from compatible devices seamlessly. This feature is ideal for those who wish to incorporate digital media into their listening experience, ensuring that they remain connected while enjoying their favorite radio shows.

Durability is also a key aspect of the Regency L900-1. Constructed with high-quality materials, this radio withstands the rigors of outdoor use. Whether you are camping, hiking, or simply enjoying a day at the beach, the solid build ensures longevity and reliability.

In summary, the Regency L900-1 combines advanced technology, user-friendly design, and robust features, making it an outstanding choice for radio enthusiasts. Its excellent reception, versatile tuning options, and modern connectivity features set it apart in the market. For those seeking a high-quality radio experience, the Regency L900-1 is undoubtedly a worthy investment.