Regency L900-1 installation manual Unit Installation with Horizontal Termination

Page 23

INSTALLATION

UNIT INSTALLATION WITH HORIZONTAL TERMINATION

(Rigid Vent Systems)

Atopclearanceof3"(76mm)andside&bottom clearance of 2"(51mm) must be maintained; except when passing through a wall, ceil- ing, or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1-1/2" (38mm). We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.

Install the vent system according to the manufacturer's instructions included with the components.

1)Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.

2)Direct Vent pipe and fittings are designed with special twist-lock connections to connect the venting system to the appliance flue outlet. A twist-lock appliance adaptor is required.

3)In conjunction with the Simpson Direct Vent Pro system, install the adaptor after the unit is set in its desired location. Put a bead of high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the inner collar. Slip the adapter over the existing inner and outer flue collar. Fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier).

4)Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips.

5)Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection.

Note: For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional.

Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.

6)Mark the wall for a 11" x 11" (279mm x 279mm) square hole. The center of the square hole should line up with the center- line of the horizontal pipe. Cut and frame the 11 inch (279mm) square hole in the exterior wall where the vent will be terminated. See diagram 2 for center line requirements.

If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, an 8" (203mm) diameter hole is acceptable.

Diagram 2

Note:

a)The horizontal run of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.

b)The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Termination Locations" section for more details.

7)Ensure that the pipe clearances to combustible materials are maintained (Diagram 5). Install the termination cap.

Note: If installing termination on a vinyl siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.

Diagram 5

The four wood screws provided should be re- placed with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

8)Before connecting the horizontal run of vent pipe to the vent termination, slide the Wall Thimble over the vent pipe. The wall thimble is required for all horizontal terminations.

9)Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap.

10)Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7).

INSTALLATION

Diagram 7

Diagram 1

Regency® L900-1 Direct Vent Gas Fireplace

23

Image 23
Contents Liberty L900-1 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Duct KIT Heat Release KIT Finished FloorClearances Mantel LEG Clearances Mantel ClearancesNON-COMBUSTIBLE Requirements Framing & FinishingVenting Introduction Unit Assembly Prior to InstallationFinishing Template Vent Restrictor Position Minimum Clearance Requirements Exterior Vent Termination RequirementsHorizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart Installation Allowable Horizontal Terminations Vent Restrictor SettingHorizontal Venting with Two 2 90o Elbows Installation Allowable Vertical Terminations Unit Installation with Horizontal Termination Minimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Unit InstallationHigh Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingWiring Diagram Aeration AdjustmentLatch Location Grate Conversion KIT #547-969 from NG to LPLP Conversion Kit Contains Qty Description HingeDoorBurner Orifi ce Handle with care. do not Force Into Position Brick Panel InstallationFor L676-1 Units only Top Brick Panel Right SideL900-1 Left Side Brick Panel Back Brick PanelVermiculite LOG SET InstallationLog kit # 547-930 contains the following pieces Description 3rd Grate Post Installation1st Grate Post Completed Log Set Installation Outer Most Bracket Hole Mesh Pull Screen InstallationLeft Side Rod Right Side Rod Inner Most Bracket HoleReplace Log G Optional Andiron InstallationFinal Installation L900-1 Log GOperating Instructions Lighting Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Copy of Lighting Plate InstructionsMaintenance DC Spark Box DC Spark BOX Battery ReplacementDC Spark BOX Replacement Rear Log Stand HingeDoor Valve Tray ReplacementCheck operation of flame control Valve TrayMain Assembly Parts ListParts List Burner & LOG Assembly Warranty Limited Lifetime WarrantyInstaller Please complete the following information

L900-1 specifications

The Regency L900-1 is a remarkable innovation in the realm of radio equipment, designed for enthusiasts and professionals alike. Renowned for its exceptional performance, this model seamlessly integrates a plethora of advanced features, making it a top choice among users.

One of the most notable characteristics of the Regency L900-1 is its outstanding reception capabilities. Equipped with cutting-edge digital signal processing technology, this radio provides crystal-clear audio quality even in congested frequency environments. This technology minimizes noise and interference, ensuring a pristine listening experience. Users will appreciate the enhanced sensitivity and selectivity, allowing them to easily tune into distant stations or weak signals.

The design of the L900-1 is user-friendly, featuring an intuitive interface that simplifies operation. The well-organized control panel includes a large LCD display that provides vital information at a glance, such as frequency, volume levels, and signal strength. The device also includes clearly marked buttons and knobs that are easy to navigate, catering to both beginners and seasoned radio operators.

Another standout feature of the Regency L900-1 is its versatile tuning options. Users can choose between manual tuning, automatic scanning, or preset channels, offering flexibility based on individual preferences. The radio covers a broad frequency range, enabling access to AM, FM, and SW bands, which broadens the spectrum of stations and content available to users.

Additionally, the L900-1 incorporates modern connectivity options. It supports Bluetooth pairing, allowing users to stream audio from compatible devices seamlessly. This feature is ideal for those who wish to incorporate digital media into their listening experience, ensuring that they remain connected while enjoying their favorite radio shows.

Durability is also a key aspect of the Regency L900-1. Constructed with high-quality materials, this radio withstands the rigors of outdoor use. Whether you are camping, hiking, or simply enjoying a day at the beach, the solid build ensures longevity and reliability.

In summary, the Regency L900-1 combines advanced technology, user-friendly design, and robust features, making it an outstanding choice for radio enthusiasts. Its excellent reception, versatile tuning options, and modern connectivity features set it apart in the market. For those seeking a high-quality radio experience, the Regency L900-1 is undoubtedly a worthy investment.