CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

INSTALLATION

Caution Requirements

The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be

recessed into combustible construction.

Clearance to Combustibles from:

Back 0" (0mm)

Side 0" (0mm)

Floor 0" (0mm)

Minimum Clearance from Top of Front Facing:

Mantel

min. 17-1/2"

(445mm)

Ceiling

49"

(1245mm) from top of front facing

Side Wall to Unit:

15-3/4"* (400mm)

Horizontal Vent Clearances to Combustibles:

Top

3"

(76mm)

Side

2"

(51mm)

Bottom

2"

(51 mm)

Vertical Vent Clearances to Combustibles:

All Sides

2"

(51mm)

Alcove Clearances:

Min. Depth

36"

(914mm)

Min. Width*

84"

(2134mm)

Min. Height

84"

(2134mm)

NOTE: Only materials such as, but not limited to durarock, wonderboard and concrete board may be put on the front face of this appliance. See specific requirements under "Framing and Finishing" section.

* Alcove side wall must have a minimum of 15-3/4" (400mm) clearance on one side.

IMPORTANT: Must install 1 set of brick panels. The operation of this unit without brick panels is prohibited.

WARNING

 

IMPORTANT

Fire hazard is an extreme risk

 

If converting this unit to LP, it is highly recommened

if these clearances (air space) to combustible materials

 

 

the conversion be done BEFORE the unit is slid into

are not adhered to. It is of greatest importance that this

 

fireplace and vent system be installed only in

 

position for ease of conversion. See "Conversion

accordance with these instructions.

 

from NG to LP" section for instructions.

 

 

 

Regency® L900-1 Direct Vent Gas Fireplace

9

Image 9
Contents Liberty L900-1 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal Safety LabelMA Code CO Detector Requirements Unit Dimensions General Safety Information InstallationInstallation Checklist Important Message Save These InstructionsHeatwave Duct KIT Heat Release KIT Manufactured Mobile Home Additional RequirementsFinished Floor Locating Your GAS FireplaceClearances Mantel LEG Clearances Mantel ClearancesNON-COMBUSTIBLE Requirements Framing & FinishingUnit Assembly Prior to Installation Finishing TemplateVenting Introduction Vent Restrictor Position Minimum Clearance Requirements Exterior Vent Termination RequirementsHorizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart Installation Allowable Horizontal Terminations Vent Restrictor SettingHorizontal Venting with Two 2 90o Elbows Installation Allowable Vertical Terminations Unit Installation with Horizontal Termination This allows for small adjustments Unit Installation With Vertical TerminationDiagram Minimum VentAstrocap XL Unit InstallationGAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High ElevationWiring Diagram Aeration AdjustmentLP Conversion Kit Contains Qty Description Conversion KIT #547-969 from NG to LPHingeDoor Latch Location GrateBurner Orifi ce Handle with care. do not Force Into Position Brick Panel InstallationL900-1 Left Side Brick Panel Top Brick Panel Right SideBack Brick Panel For L676-1 Units onlyLOG SET Installation Log kit # 547-930 contains the following pieces DescriptionVermiculite 3rd Grate Post Installation1st Grate Post Completed Log Set Installation Left Side Rod Right Side Rod Mesh Pull Screen InstallationInner Most Bracket Hole Outer Most Bracket HoleFinal Installation L900-1 Optional Andiron InstallationLog G Replace Log GOperating Instructions Normal Operating Sounds GAS Appliances For Your Safety Read Before LightingCopy of Lighting Plate Instructions Lighting InstructionsMaintenance DC Spark BOX Battery Replacement DC Spark BOX ReplacementDC Spark Box Rear Log Stand HingeDoor Valve Tray ReplacementCheck operation of flame control Valve TrayMain Assembly Parts ListParts List Burner & LOG Assembly Warranty Limited Lifetime WarrantyInstaller Please complete the following information