Wayne 3514, 3014, 3018DLX user manual Door Tests Before Starting, Door Test One

Page 5

Door Tests Before Starting

Before you begin, complete the following two tests to insure that the door is balanced and working properly. A door that binds, sticks or is out of balance could cause severe injury. Do not attempt to compensate for an improperly adjusted door by the installation of an opener. This will interfere with the proper operation of the opener mechanism and/or may damage the door. Have a qualified service person make any needed adjustments or repairs to cables, spring assemblies and other hardware before proceeding with installation.

Door Test One

Raise and lower the door and check closely for any sticking or binding that occurs.

Lift the door approximately half way open, as illustrated. When releasing the door, it should stay in position. If spring pressure pulls the door further open or door weight pulls it further down, your door is not properly adjusted.

Door Test Two

When properly installed, a door should remain clear of the opening, when allowed to rest at its natural, full open position.

If “door drift” pulls door back into opening or spring ten- sion is not sufficient to pull door totally clear of opening, the door is not properly adjusted.

IMPORTANT PRE-ASSEMBLY CHECK

If assembling a motor head unit from a factory sealed box skip this check.

Every Power Head Unit is factory tested and shipped with the limit switch adjustment in the door CLOSED position.

If the Motor Power Head Unit has been powered up before assembly, perform the following steps to insure that the limit switch adjustment is in the door CLOSED position.

Connect Motor Head Unit to a power source and short across the screw terminals labeled “PB” and “COM” with a metal screw driver.

Motor should start; run through a full OPEN cycle, and stop. This will leave Motor Power Head Unit in OPEN position. To get Motor Power Head Unit back to full CLOSE position, short and hold motor terminals again. Continue to short terminals until Motor Power Head Unit stops in the CLOSED position. Disconnect from power source and proceed to assembly.

5

Image 5
Contents Owner Installation Important Installation Instructions Page Before Starting FeaturesDoor Test One Door Tests Before StartingTools You’ll Need Part Identification Hardware Identification Step One Rail Assembly Rail AssemblyStep Three Mounting Front Rail Assembly Step Two Trolley AlignmentStep Six Rail Assembly Alignment Step Four Setting The ChainStep Five Setting The Chain Latch Assembly Positioning and Installing Front Wall Bracket Attaching Motor Power Head Unit to RailMounting Motor End of Opener Attach Unit to Front Wall BracketPositioning the Motor End of Operator Mounting Door Bracket Installing LightInstalling Wired Wall Station if included Install Entrapment Warning Label Installing Deluxe Wireless Wall Station if includedInstall Wireless Infrared Safety Sensor Install Wireless Infrared Safety Sensor BracketInstall Wired Infrared Safety Sensor Wall Mounting Brackets Connecting Wired Infrared Safety Sensor to Opener Install Wiring for Wired Infrared Safety SensorConnecting Electrical Power Mount Wired Infrared Safety SensorsChanging Wireless Wall Station Code Wireless Wall Station Security Code Change and ProgrammingAlignment of the Wireless Infrared Safety Sensors Changing the Transmitter Code Alignment of the Wired Infrared Safety SensorsTwo Button Transmitter Security Code Change and Programming Programming Transmitter to Power Head UnitSetting Trolley Close Position Connecting Cushion Arm to TrolleyIMPORTANT! Test Contact Obstruction Sensing Feature Connecting Door Arm to DoorInfrared Safety Sensor Obstruction Test Setting Door Opening TravelInstalling Wireless Keyless Entry If Included Programming Wireless Keyless Entry If IncludedAdjustment # 1 Opening and Closing Force AdjustmentsAdjustment # 3 Positive Mechanical Door Lock Adjustment # 2 Contact Obstruction Sensing Closing DirectionImportant Safety Instructions Operation of Your Opener HOW to Operate the Wireless Keyless Entry if IncludedOpener Power Head Controls HOW to Operate the Wireless Wall Station If IncludedPage Once a Year Once a MonthTwice a Year Trouble Shooting Section Parts Breakdown Rail Assembly All Models Description Per Unit # Per Unit Classicdrive Accessories Pre-drill a 5/64 pilot Hole 3/4 deep Cut Template to Aid in Keyless Entry Installation See StepLimited Lifetime Warranty Questions?

3514, 3014, 3018, 3018DLX specifications

Wayne 3014, 3018, 3018DLX, and 3514 are a series of innovative fuel dispensers designed to cater to the evolving needs of the retail fueling industry. These models embody advanced engineering, reliability, and efficiency, making them ideal solutions for gas station operators looking to enhance their service offerings.

The Wayne 3014 series is characterized by its compact design, making it a perfect fit for locations with space constraints. It features a user-friendly interface, which allows for easier interaction for both attendants and customers. The sleek and modern look of the 3014 gives stations a contemporary feel while maintaining durability against the elements.

The 3018 model builds on the robust foundation of the 3014 but adds additional features for increased throughput. With capabilities to handle multiple products, the 3018 allows for various fuel types to be dispensed efficiently, catering to the diverse needs of customers. The model is equipped with advanced metering technologies, ensuring accurate measurement and reducing loss through evaporation or spillage.

For those seeking a more premium option, the 3018DLX stands out with its enhanced features and aesthetics. It offers an integrated payment system, supporting both card and mobile payments, which vastly improves transaction speed and customer satisfaction. The dispenser is also designed with a customizable interface that allows operators to promote special offers or loyalty programs directly on the screen.

The Wayne 3514 takes technology a notch higher, incorporating robust software support that enables real-time data analytics. This feature allows station owners to monitor sales trends and inventory levels efficiently, leading to optimized operations and better decision-making. The 3514 also supports future upgrades, ensuring that the infrastructure can adapt as technology evolves.

All these models prioritize safety and regulatory compliance, featuring advanced leak detection systems and secure payment options. Additionally, they are built to withstand the most challenging environments, reducing downtime and maintenance costs.

In summary, the Wayne 3014, 3018, 3018DLX, and 3514 are more than just dispensers; they represent the future of fueling technology. With their focus on user experience, adaptability, and operational efficiency, these models are set to redefine fuel dispensing in the retail sector. Achieving success in a competitive market is easier with equipment designed to deliver outstanding performance and reliability.