Wayne 370100-001, WCP85 Troubleshooting Chart, Symptom Possible Causes Corrective Action

Page 5

WCP85

Troubleshooting Chart

Pump may start unexpectedly. Disconnect power supply before servicing.

Symptom

Possible Cause(s)

Corrective Action

 

 

 

 

 

 

 

 

 

Pump fails to run

1. Pump not plugged in

1. Plug in.

 

 

 

 

2. Low voltage, blown fuse, open

2. Have a certified electrician check fuse circuit.

 

 

 

 

circuit

 

 

 

 

 

3. Reservoir is absent of

3. Make sure that there is adequate condensate level in

 

 

 

 

condensate

reservoir. Check drain lines and/or discharge line for

 

 

 

 

 

obstructions.

 

 

 

 

4. Drain/discharge lines blocked

4. Check drain lines and/or discharge line for obstructions.

 

 

 

 

 

 

 

 

 

Pump emits loud noises

Foreign material in reservoir

Refer to Maintenance section for cleaning instructions.

 

 

 

when operating

 

 

 

 

 

 

 

 

 

 

 

Pump operates but

1. Float is sticking

1. Refer to Maintenance section for cleaning instructions.

 

 

 

there is no flow of

2. Discharge height greater than

2. Measure from bottom of pump to highest point. Rework

 

 

 

liquid

15 feet

discharge if height is greater than 15’. Refer to Installation

 

 

 

 

 

Step 4 for instructions.

 

 

 

 

3. Obstruction in discharge tube

3. Check discharge line for blockage. Remove debris.

 

 

 

 

4. Blockage in check valve

4. Refer to Maintenance section for cleaning instructions.

 

 

 

 

5. Damaged check valve

5. Contact Wayne.

 

 

 

 

 

 

 

 

 

Liquid drains back into

1. Damaged check valve

1. Contact Wayne.

 

 

 

pump from discharge

2. Blockage in check valve

2. Refer to Maintenance section for cleaning instructions.

 

 

 

line

3. Discharge line is 5’ or less

3. Condensate liquid may drain out of line into reservoir due

 

 

 

 

 

to discharge height. This is normal. No action is necessary.

 

 

 

 

 

 

 

 

 

Liquid leaks from

1. Check valve fastened too tight

1. Check valve should be hand-tightened, then tightened an

 

 

 

around check valve

or too loose

additional 1/2 turn with a 9/16” wrench.

 

 

 

 

2. Damage to O-ring

2. Replace with a 1/2” ID x 11/16” OD x 3/32” thick O-ring or

 

 

 

 

 

contact Wayne Technical Service at 1-800-237-0987.

 

 

Before servicing a pump, always shut off the main power breaker and then unplug the pump. Make sure you are not standing in water. Make sure you are wearing insulated, protective-

soled shoes. Under flooded conditions, check your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal. If the above checklist does not solve the problem, contact Wayne Technical Service at 1-800-237-0987.

5

Image 5
Contents General Safety Information Safety GuidelinesSpecifications DescriptionInstallation of Pipe InstallationInstallation of Condensate Drain Lines Mounting Condensate UnitTips for Easy Installation Installation of Discharge LineInstallation of Safety Switch if Applicable Cleaning Check Valve MaintenanceCleaning Reservoir ImpellerSymptom Possible Causes Corrective Action Troubleshooting ChartLimited Warranty Medidas de Seguridad DescripciónInformaciones Generales de Seguridad EspecificacionesPaso 1 Instalación DE LA Tubería Informaciones Generales deInstalación Paso 4 Instalación DE LA Línea DE Descarga Paso 2 Montaje DE LA Unidad DE CondensaciónPaso 3 Instalación DE LAS Líneas DE Drenaje DEL Condensador Mantenimiento Guía de Diagnóstico de Averías Garantía Limitada

370100-001, WCP85 specifications

The Wayne 370100-001, also known as the WCP85, is a versatile and highly efficient fuel dispenser that epitomizes innovation and reliability in the fuel retail industry. It is designed to meet the demands of various fueling environments while providing an unparalleled user experience. The WCP85 series stands out for its robust construction and advanced technological features that ensure optimal performance.

One of the primary characteristics of the Wayne WCP85 is its modular design, which allows for easy customization according to the specific needs of fuel retailers. This adaptability enables operators to configure the dispenser for multiple fuel types, including gasoline, diesel, and alternative fuels, thereby catering to a wide range of customer preferences. Additionally, its ability to support different payment systems makes it compatible with various payment methods, enhancing the customer experience at the pump.

The WCP85 incorporates advanced measurement technology that ensures accurate fuel dispensing. Its state-of-the-art flow meters are designed to meet or exceed industry standards, reducing the risk of inaccuracies and boosting customer trust. Furthermore, the dispenser is equipped with high-speed pumping capabilities, allowing for faster transactions and reduced wait times for customers.

In terms of safety and compliance, the Wayne WCP85 is designed with robust leak detection and monitoring systems. These features not only adhere to regulatory requirements but also enhance the overall safety of fuel dispensing operations. The dispenser also includes features such as emergency shut-off systems and anti-tampering mechanisms to further ensure safety in potentially hazardous environments.

An important feature of the WCP85 is its user-friendly interface, which includes a high-resolution display and intuitive navigation. This makes it easy for customers to select fuel types, enter payment information, and access promotional content. Additionally, the dispenser's design incorporates ergonomic elements, ensuring that it meets the needs of all users.

Moreover, the WCP85 supports connectivity options, allowing for seamless integration with backend systems, payment processors, and loyalty programs. This connectivity enhances operational efficiency and can help fuel retailers gather valuable data for optimizing their operations.

In summary, the Wayne 370100-001 WCP85 is a cutting-edge fuel dispenser that combines flexibility, safety, and advanced technology, making it an ideal choice for fueling stations looking to enhance their service quality and operational efficiency. With its robust construction, user-friendly features, and reliable performance, the WCP85 is poised to meet the evolving demands of the fuel retail landscape.