Wayne 350705-001 operating instructions Submersible Sump Pump, Submersible Series, Unpacking

Page 1

Operating Instructions and Parts Manual

Submersible Series

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Submersible

Sump Pump

Description

The submersible pump is designed for home sump applications. The unit is equipped with an 8-ft long, 3-prong grounding type power cord. Motor is oil filled and sealed for cooler running and designed to operate under water. A float switch is provided for automatic pump operation. This pump is not suitable for aquatic life.

Unpacking

Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death.

General Safety Information

Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do

not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Personal injury and/or property damage could result.

This pump is not designed to handle

salt water, brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials. Pump damage could occur if used in these applications and will void warranty.

All wiring must be performed by a

qualified electrician. Failure to follow this warning could result in fatal electrical shock.

If the basement has water or moisture on the floor, do not walk on wet area until all power is turned off. If the shutoff box is

in the basement, call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.

Switch Housing

Float

Bracket

Float

Figure 1

A backup system should be used.

Wayne offers Model ESP15.

Assembly

VERTICAL FLOAT SWITCH (FLOAT ONLY)

Place the float bracket onto the handle of the motor housing and slide the switch assembly securely into place.

Installation

1.Install pump in a sump pit with minimum size as shown in Figure 2. Construct sump pit of tile, concrete, steel or plastic.

2.The unit should be located and rest on a solid, level foundation. Do not place pump directly on clay, earth, gravel or sandy surface. These surfaces contain small stones, gravel, sand, etc. that may clog or damage the pump and cause pump failure.

Flood risk. If flexible discharge

hose is used, make sure pump is secured in sump pit to prevent movement. Failure to secure pump could allow pump movement and switch interference and prevent pump from starting or stopping.

3.Thread check valve (Wayne offers Model 66005-WYN) into pump body carefully to avoid stripping or cross threading. Do not use pipe joint sealant.

4.Connect 1-1/2” rigid pipe to rubber boot on check valve. Reverse boot for 1-1/4”

diameter pipe. Tighten hose clamps.

Support pump and piping when

assembling and after installation. Failure to do so could cause piping to break, pump to fail, etc. which could result in property damage and/or personal injury.

5.Protect electrical cord from sharp object, hot surfaces, oil and chemicals. Avoid kinking the cord and replace damaged cords immediately.

IMPORTANT: Make sure there is adequate room for the switch to operate.

6.A sump pit cover must be installed to prevent debris from clogging or damaging the pump.

Min. Diameter

Float 11”

Tether 14”

Figure 2

Operation

Always disconnect the power source before attempting to install,

service, relocate or maintain the pump. Never touch sump pump, pump motor, water or discharge piping when pump is connected to electrical power. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.

1.A ground fault circuit interrupter (GFCI) is required.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2005 Wayne Water Systems

For parts, product & service information

350705-001 7/05

visit www.waynepumps.com

1

Image 1
Contents Submersible Series Submersible Sump PumpUnpacking Troubleshooting Chart MaintenanceSpecifications Symptom Possible Causes Corrective ActionLimited Warranty Série Immergée Pompe de Puisard ImmergéeEntretien Fonctionnement SuiteGuide de Dépannage SpécificationsSerie Sumergible Guía de Diagnóstico de Averías Funcionamiento ContinuaciónMantenimiento EspecificacionesGarantía Limitada Garantie Limitée

Submersible Series, 350705-001 specifications

The Wayne Submersible Series 350705-001 is a highly regarded solution in the realm of sewage and wastewater management. This powerful submersible pump is engineered to deliver high performance and reliability, making it an essential tool for residential and commercial applications alike.

One of the standout features of the Wayne Submersible 350705-001 is its robust construction. The durable cast iron housing is designed to withstand the harsh conditions typically found in sewage applications, ensuring longevity and resilience. With a power rating of 1/2 horsepower, this pump is capable of handling high volumes of wastewater, while its efficient motor operates quietly, reducing noise pollution in the environment.

The pump boasts a maximum flow rate of approximately 60 gallons per minute, making it suitable for a variety of settings, including basements, drainage pits, and effluent waste management systems. It features a reliable vortex impeller, which efficiently handles solids up to 2 inches in diameter, preventing clogging and ensuring uninterrupted operation. The unique design of the impeller also allows for better flow rates and higher efficiency, ultimately leading to reduced energy consumption.

Another significant aspect of the Wayne Submersible 350705-001 is its innovative float switch technology. Designed for automatic operation, this float switch can detect water levels and activate the pump as needed, providing hassle-free operation and peace of mind for users. This feature not only aids in maintaining desired water levels but also significantly reduces the risk of flooding in critical areas.

Easy installation is a hallmark of the Wayne Submersible pump series. The 350705-001 comes with a standard 1-1/2 inch discharge, compatible with most existing plumbing systems. Its compact design also allows it to fit in tight spaces, making it versatile for various setups.

With a commitment to quality and performance, Wayne stands behind its products with a warranty, offering customers further assurance of their investment. The combination of strength, efficiency, and user-friendly design makes the Wayne Submersible Series 350705-001 an excellent choice for anyone in need of effective wastewater management solutions. Whether for residential use in a basement or for more extensive commercial systems, this pump stands out as a reliable ally in tackling challenging water removal tasks.