Wayne Submersible Series Maintenance, Troubleshooting Chart, Specifications, Construction

Page 2

Operating Instructions and Parts Manual

Operation (Continued)

Risk of electrical shock! This pump

is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock.

Never cut off the round grounding prong.

Cutting the cord or plug will void the warranty and make the pump inoperable.

2.This pump is only for use on 120 Volt (single-phase), 60 hz, 15 amp service and is equipped with a 3-conductor cord and 3-prong, grounding type plug. Insert the float switch cord plug directly into a 120 volt outlet.

3.Insert the pump power cord plug directly into the back of the float switch cord plug (See Fig. 3).

Figure 3

4.Fill sump with water. The pump will start automatically when the water has filled the sump to the cut-in level. The pump will stop when the water reaches the cut-out level. See specifications for cut- in/out levels. The pump will recycle thereafter as required.

5.Do not operate the pump unless it is submerged in water. Dry running causes pump failure.

6.The motor is equipped with an automatic reset thermal protector.

7.While the pump is draining the pit, verify that the discharge piping is carrying the water to a point several feet away from the foundation.

8.If pump discharge line is exposed to freezing temperature, the exposed line must be pitched to drain. Trapped water will freeze and damage the pump.

Maintenance

Always disconnect the electrical supply before attempting to install, service, relocate or

perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical

shock. Only qualified electricians should repair this unit. Improper repair could result in fatal electrical shock.

1.Let the pump cool for a minimum of two hours before servicing because the pump contains hot oil under pressure and the motor is hot.

2.Disassembly of the motor prior to expiration of warranty will void the warranty. If repairs are required, see troubleshooting chart.

4.Inlet should be kept clean and free of all foreign objects and inspect annually. A clogged inlet will damage pump.

5.Pump should be checked monthly for proper operation.

This pump contains dielectric oil for

cooling. This oil can be harmful to the environment. Check the state environmental laws before disposing this oil.

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

 

 

 

 

 

 

 

Pump will not start or

1.

Blown fuse

1.

If blown, replace with proper sized fuse or reset breaker

 

run

2.

Low line voltage

2.

If voltage is under 108 volts, check wiring size

 

 

3.

Defective motor

3.

Replace pump

 

 

4.

Defective float switch

4.

Replace float switch

 

 

5.

Impeller bound-up

5.

If impeller will not turn, remove housing and remove blockage

 

 

6.

Float obstructed

6.

Make sure float move freely up and down

 

 

 

 

 

 

 

Pump starts and stops

1.

Backflow of water from piping

1.

Install or replace check valve (Wayne check valve kit #66005-WYN)

 

too often

2.

Faulty float switch

2.

Replace float switch

 

 

 

 

 

 

 

Pump will not shut off

1.

Defective float switch

1.

Replace float switch

 

or thermal protector

2.

Obstacle in piping

2.

Remove pump and clean pump and piping

 

turns off

3.

Float obstructed

3.

Make sure float move freely up and down

 

 

 

 

 

 

 

Pump operates but

1.

Low line voltage

1.

If voltage is under 108 volts, check wiring size

 

delivers little or no

2.

Plugged impeller

2.

Clean out impeller

 

water

 

 

 

 

 

Specifications

Power supply requirements

120V, 60 hz

 

 

Motor

Single phase, oil filled

 

Liquid temperature range

40°F to 120°F

 

 

Circuit requirements

15 amps (min)

 

Dimensions

11” high x 9” base

 

Cut-in level (factory set)

Tether

...14”

Float

7”

Cut-out level (factory set)

Tether

...7”

Float

2 1/2”

www.waynepumps.com

Construction

Motor housing

.................................Glass reinforced thermoplastic

Volute

Thermoplastic

Impeller

Glass reinforced thermoplastic

Shaft

416 Stainless steel

Seals

Buna N

Discharge

11/2” NPT

2

Image 2
Contents Unpacking Submersible Sump PumpSubmersible Series Specifications MaintenanceTroubleshooting Chart Symptom Possible Causes Corrective ActionLimited Warranty Pompe de Puisard Immergée Série ImmergéeGuide de Dépannage Fonctionnement SuiteEntretien SpécificationsSerie Sumergible Mantenimiento Funcionamiento ContinuaciónGuía de Diagnóstico de Averías EspecificacionesGarantie Limitée Garantía Limitada

Submersible Series, 350705-001 specifications

The Wayne Submersible Series 350705-001 is a highly regarded solution in the realm of sewage and wastewater management. This powerful submersible pump is engineered to deliver high performance and reliability, making it an essential tool for residential and commercial applications alike.

One of the standout features of the Wayne Submersible 350705-001 is its robust construction. The durable cast iron housing is designed to withstand the harsh conditions typically found in sewage applications, ensuring longevity and resilience. With a power rating of 1/2 horsepower, this pump is capable of handling high volumes of wastewater, while its efficient motor operates quietly, reducing noise pollution in the environment.

The pump boasts a maximum flow rate of approximately 60 gallons per minute, making it suitable for a variety of settings, including basements, drainage pits, and effluent waste management systems. It features a reliable vortex impeller, which efficiently handles solids up to 2 inches in diameter, preventing clogging and ensuring uninterrupted operation. The unique design of the impeller also allows for better flow rates and higher efficiency, ultimately leading to reduced energy consumption.

Another significant aspect of the Wayne Submersible 350705-001 is its innovative float switch technology. Designed for automatic operation, this float switch can detect water levels and activate the pump as needed, providing hassle-free operation and peace of mind for users. This feature not only aids in maintaining desired water levels but also significantly reduces the risk of flooding in critical areas.

Easy installation is a hallmark of the Wayne Submersible pump series. The 350705-001 comes with a standard 1-1/2 inch discharge, compatible with most existing plumbing systems. Its compact design also allows it to fit in tight spaces, making it versatile for various setups.

With a commitment to quality and performance, Wayne stands behind its products with a warranty, offering customers further assurance of their investment. The combination of strength, efficiency, and user-friendly design makes the Wayne Submersible Series 350705-001 an excellent choice for anyone in need of effective wastewater management solutions. Whether for residential use in a basement or for more extensive commercial systems, this pump stands out as a reliable ally in tackling challenging water removal tasks.