Nilfisk-Advance America 01610A manual Introduction, Preparing the Machine for USE, Modifications

Page 5

ENGLISH EN

INTRODUCTION

This manual will help you get the most from your Nilfisk floor machine. Read it thoroughly before operating the machine.

This product is intended for commercial use only.

PARTS AND SERVICE

Repairs, when required, should be performed by your Authorized Nilfisk Service Center, who employs factory trained service personnel, and maintains an inven- tory of Nilfisk original replacement parts and accessories.

MODIFICATIONS

Modifications and additions to the cleaning machine which affect capacity and safe operation shall not be performed by the customer or user without prior written approval from Nilfisk-Advance Inc. Unapproved modifications will void the machine warranty and make the customer liable for any resulting accidents.

NAME PLATE

The Model Number and Serial Number of your machine are shown on the Nameplate on the bottom of the machine. This information is needed when ordering repair parts for the machine. Use the space below to note the Model Number and Serial Number of your machine for future reference.

MODEL NUMBER

SERIAL NUMBER

UNCRATE THE MACHINE

When the machine is delivered, carefully inspect the shipping carton and the machine for damage. If damage is evident, save the shipping carton so that it can be inspected. Contact the Nilfisk Customer Service Department imme- diately to file a freight damage claim (phone number is provided on the back cover of this manual).

PREPARING THE MACHINE FOR USE

WARNING!

Use extreme caution when working with batteries. Sulfuric acid in batteries can cause severe injury if allowed to contact the skin or eyes. Explosive hydrogen gas is vented from inside the batteries through openings in the battery caps. This gas can be ignited by any arc, spark or flame.

WHEN SERVICING BATTERIES....

Remove all jewelry

Do not smoke

Wear safety glasses

Work in a well-ventilated area

Do not allow tools to touch more than one battery terminal at a time.

CAUTION!

Electrical components in this machine can be severely damaged if the batteries are not installed and connected properly. Batteries should be installed by your local Nilfisk dealer or by a qualified electricain.

The UHB 51-1500 may be used with three 12 volt 185 amp hour batteries or three 12 volt 234 amp hour AGM batteries.

CAUTION!

The battery charger must be reprogrammed when switching from lead acid to AGM batteries. See the Charger Manual for instructions.

revised 7/11

FORM NO. 71456A - UHB 51-1500 - 5

Image 5
Contents UHB51-1500 Table of Contents Important Safety Instructions Know Your Machine Modifications IntroductionPreparing the Machine for USE Form no a UHB PAD Installation Installing the BatteriesDust BAG Installation Adjusting PAD PressureSpecifications MaintenanceTroubleshooting Maintenance SchedulePivot bracket Slots to allow adjustment Indice Guarde Estas Instrucciones ¡ADVERTENCIAConozca SU Máquina Modificaciones ¡ADVERTENCIA¡PRECAUCIÓN Retire la cubierta Reemplace la bolsa de polvo Instalación DE LAS Baterías ImportanteInstalación DE LA Almohadilla Ajuste DE LA Presión DE LA ALMO- HadillaMantenimento Resolución DE ProblemasMénsula de pìvote Ranuras para permitir el ajuste Table DES Matières Programme de maintenanceConservez CES Consignes AvertissementLA Decouverte DE Votre Machine Avertissement Plaque SignalétiquePièces ET Entretien AltérationsRetirez le capot Remplacez le sac à poussières Installation DU Disque Installation DES BatteriesInstallation DU SAC À Poussières Réglage DE LA Pression DU DisqueMaintenance DES Batteries Programme DE MaintenanceSupport du pivot Encoches de réglage Page UHB51-1500 Table of Contents UHB51-1500 Assembly UHB51-150008-4 08-4ASSEMBLY UHB51-1500 Frame Assy Before February Mainframe, 20 not available for sale Frame Assy After February Frame Assy After February Handle Assy 08-07 Body Assy Body Assy Head Assy 10-05 08-4 11-7 Active VAC KITBlack RED TransaxleLadder Diagram Page Page Year of Affixing the CE marking Nilfisk-Advance A/S