Lifebreath 1000RHCAC, 1200DDPOOL Troubleshooting Your HRV System, Symptom Cause Solution

Page 23

Troubleshooting Your HRV System

SYMPTOM

CAUSE

SOLUTION

Poor Air Flows

• 1/4” (6 mm) mesh on the outside hoods is plugged

• clean exterior hoods or vents

 

• filters plugged

• remove and clean filter

 

• core obstructed

• remove and clean core

 

• house grilles closed or blocked

• check and open grilles

 

• dampers are closed if installed

• open and adjust dampers

 

• poor power supply at site

• have electrician check supply voltage at house

 

• ductwork is restricting HRV

• check duct installation

 

• improper speed control setting

• increase the speed of the HRV

 

• HRV airflow improperly balanced

• have contractor balance HRV

 

 

 

Supply air feels cold

• poor location of supply grilles, the airflow may irritate

• locate the grilles high on the walls or under the baseboards,

 

the occupant

install ceiling mounted diffuser or grilles so as not to directly

 

 

spill the supply air on the occupant (eg. over a sofa)

 

• outdoor temperature extremely cold

• turn down the HRV supply speed. A small duct heater

 

 

(1kw) could be used to temper the supply air

 

 

• placement of furniture or closed doors is restricting the

 

 

movement of air in the home

 

 

• if supply air is ducted into furnace return, the furnace fan

 

 

may need to run continuously to distribute ventilation

 

 

air comfortably

 

 

 

Dehumidistat is not Operating

• improper low voltage connection

• check that the correct terminals have been used

 

• external low voltage is shortened out by a staple or nail

• check external wiring for a short

 

• check dehumidistat setting it may be on OFF

• set the dehumidistat at the desired setting

 

 

 

Humidity Levels are too High

• dehumidistat is set too high

• set dehumidistat lower

Condensation is appearing on the windows

• HRV is undersized to handle a hot tub, indoor pool, etc.

• cover pools, hot tubs when they are not in use

 

• lifestyle of the occupants

• avoid hanging clothes to dry, storing wood and venting clothes

 

 

dryer inside. Heating wood may have to be moved outside

 

• moisture coming into the home from an unvented or

• vent crawl space and place a vapour barrier on the floor

 

unheated crawl space

of the crawl space

 

• moisture is remaining in the washroom and kitchen areas

• ducts from the washroom should be sized to remove moist

 

 

air as effectively as possible, use of a bathroom fan for

 

 

short periods will remove additional moisture

 

• condensation seems to form in the spring and fall

• on humid days, as the seasons change, some condensation

 

 

may appear but the homes air quality will remain high with

 

 

some HRV use

 

• HRV is set at too low a speed

• increase speed of the HRV

 

 

 

Humidity Levels are too Low

• dehumidistat control set too low

• set dehumidistat higher

 

• blower speed of HRV is too high

• decrease HRV blower speed

 

• lifestyle of occupants

• humidity may have to be added through the use of humidifiers

 

• HRV air flows may be improperly balanced

• have a contractor balance HRV airflows

 

 

 

HRV and / or Ducts Frosting up

 

• Note: minimal frost build-up is expected on cores before

 

 

unit initiates defrost cycle functions

 

• HRV air flows are improperly balanced

• have HVAC contractor balance the HRV

 

• malfunction of the HRV defrost system

• using the self-test feature at the Base Module, press the fan

 

 

control symbol, the damper defrost unit should cycle its full

 

 

travel when working properly.

 

 

 

Condensation or Ice Build Up in Insulated Duct to

• incomplete vapour barrier around insulated duct

• tape and seal all joints

the Outside

• a hole or tear in outer duct covering

• tape any holes or tears made in the outer duct covering

 

 

• ensure that the vapour barrier is completely sealed

 

 

 

Water in the bottom of the HRV

• drain pans plugged

• ensure O-Ring on drain nozzle sits properly

 

• improper connection of HRVs drain lines

• look for kinks in line

 

• HRV is not level

• check water drain connections

 

• drain lines are obstructed

• make sure water drains properly from pan

 

• HRV heat exchange core is not properly installed

 

23

Image 23
Contents 1000RHC For ModelsIntroduction Table of ContentsPerformance Model 700DD PoolModel 1200DD Pool SpecificationsHydronic Reheat Coil Model 1000RHC Model 1000RHCACMoisture removal capabilities Sizing your Pool Heat Recovery VentilatorCalculation System InstallationEvaporation Rate Flowrate Factor Typical Duct Layout Sketch #1 Installation DiagramsTypical Duct Layout Sketch #2 Ductwork System Location for MountingStale Air Return System Outside WeatherhoodsDucting from Weatherhoods Warmside Ducting GeneralFresh Air Supply System Saddle Installation Various Installation TypesAutomatic Self Test of Defrost Systems Electrical ConnectionsOperation Operation of the HRVDefrost Mode Ducting Requirements & Mode of OperationVentilation Mode Recirculation ModeHydronic Reheat Coil Speed Selection and ControlsAir Conditioning DX Coil Prior to balancing, ensure that Pitot Tube Air Flow BalancingMotor Service/MaintenanceFilters General MaintenanceSymptom Cause Solution Troubleshooting Your HRV SystemStyle Units only Two Year Limited Warranty 15 Year Core Warranty Commercial Lifebreath Heat Recovery Ventilators

1200DDPOOL, 700DDPOOL, 1000RHCAC, 1000RHC specifications

Lifebreath is a brand renowned for its commitment to energy-efficient indoor air quality solutions. Among their offerings, the Lifebreath 700DDPOOL, 1200DDPOOL, 1000RHCAC, and 1000RHC stand out as exemplary products designed for various residential and commercial settings. These units leverage cutting-edge technologies to provide superior ventilation, heat recovery, and air quality management.

The Lifebreath 700DDPOOL is specifically designed for indoor pools and similar environments. This model boasts dual-flow ventilation, which simultaneously circulates fresh air into the space while expelling stale air. The 700DDPOOL features a built-in dehumidistat, ensuring optimal humidity levels are maintained, which is vital for preventing mold and preserving air quality. Its energy recovery capabilities make it an eco-friendly choice, reclaiming heat from exhaust air to pre-condition incoming air, thus significantly reducing heating costs.

The Lifebreath 1200DDPOOL offers similar benefits but on a larger scale. With a higher airflow capacity, the 1200DDPOOL is ideal for larger pool areas or heavily used commercial spaces. It also incorporates advanced filtration technologies that trap allergens, dust, and pollutants, resulting in cleaner air. Both the 700DDPOOL and 1200DDPOOL are engineered for easy installation and maintenance, with features like removable filters and accessible components.

The Lifebreath 1000RHCAC and 1000RHC models shift focus towards whole-home ventilation and air conditioning solutions. The 1000RHCAC combines heat recovery with air conditioning capabilities, allowing for year-round climate control. The unit’s heat exchanger efficiently recovers heat from the outgoing air and transfers it to the incoming air, ensuring that energy is conserved even during cooling seasons.

In contrast, the Lifebreath 1000RHC emphasizes effective heat recovery without an integrated air conditioning system, making it an excellent choice for areas where cooling is not a priority. Both models boast a quiet operation, ensuring no disruption to daily living, along with energy-efficient certifications that appeal to eco-conscious consumers.

Overall, Lifebreath’s 700DDPOOL, 1200DDPOOL, 1000RHCAC, and 1000RHC models provide exceptional performance, versatility, and user-friendly features. These air management systems represent the future of sustainable indoor air quality solutions, meeting diverse ventilation needs while prioritizing energy efficiency and comfort. With Lifebreath, users can breathe easier knowing they have invested in cutting-edge technology designed for health and efficiency.