ICP DAS USA DFS2A324J2A, DFS2A318J2A, DFS2H324J2A, DFS2H318J2A specifications 100.4

Page 14

Table 7 -DFS2A/DFS2H Thermistor TH-1, TH-2, and TH-3 Temperature to Resistance Conversion (Cont.)

TEMPEATURE

TEMPERATURE

TEMPERATURE

TEMPERATURE

MINIMUM

MEAN

MAXIMUM

TOLERANCE

TOLERANCE

RESISTANCE

RESISTANCE

RESISTANCE

(0F)

(0C)

(0F)

(0C)

(K)

(K)

(K)

 

 

100.4

38

±2.0

±1.1

3.058

3.167

3.277

102.2

39

±2.0

±1.1

2.956

3.062

3.169

104.0

40

±2.0

±1.1

2.857

2.961

3.066

105.8

41

±2.0

±1.1

2.762

2.864

2.966

107.6

42

±2.0

±1.1

2.671

2.770

2.870

109.4

43

±2.2

±1.2

2.583

2.679

2.777

111.2

44

±2.2

±1.2

2.498

2.593

2.688

113.0

45

±2.2

±1.2

2.417

2.509

2.602

114.8

46

±2.2

±1.2

2.339

2.429

2.520

116.6

47

±2.2

±1.2

2.264

2.352

2.441

118.4

48

±2.3

±1.3

2.192

2.227

2.364

120.2

49

±2.3

±1.3

2.122

2.206

2.291

122.0

50

±2.3

±1.3

2.055

2.137

2.220

123.8

51

±2.3

±1.3

1.990

2.070

2.151

125.6

52

±2.3

±1.3

1.928

2.006

2.085

127.4

53

±2.3

±1.3

1.867

1.943

2.021

129.2

54

±2.3

±1.3

1.809

1.883

1.959

131.0

55

±2.5

±1.4

1.753

1.826

1.900

132.8

56

±2.5

±1.4

1.699

1.770

1.842

134.6

57

±2.5

±1.4

1.647

1.717

1.787

136.4

58

±2.5

±1.4

1.597

1.665

1.734

138.2

59

±2.5

±1.4

1.549

1.615

1.683

140.0

60

±2.5

±1.4

1.503

1.567

1.633

141.8

61

±2.7

±1.5

1.458

1.521

1.585

143.6

62

±2.7

±1.5

1.414

1.476

1.539

145.4

63

±2.7

±1.5

1.372

1.432

1.494

147.2

64

±2.7

±1.5

1.332

1.391

1.451

149.0

65

±2.7

±1.5

1.293

1.350

1.409

150.8

66

±2.9

±1.6

1.255

1.311

1.369

152.6

67

±2.9

±1.6

1.219

1.274

1.330

154.4

68

±2.9

±1.6

1.184

1.237

1.292

156.2

69

±2.9

±1.6

1.150

1.202

1.256

158.0

70

±2.9

±1.6

1.117

1.168

1.221

NOTE: Resistance tolerance ± 3%.

14

Image 14
Contents General ContentsSafety Considerations Parts List High Wall Units QTY DiagramPhysical Data Cooling Only Physical Data Heat PumpInstall the Mounting Bracket InstallationIndoor Unit Installation Discharge opening Wire the Indoor Unit ReassembleMake Drainage Connections Mount the indoor unit on the mounting bracketAttach the Remote Controller Mounting Bracket OptionalIndoor unit LED’s and Wiring MCA Electrical Data, Indoor Units 30VDCElectrical Data, Outdoor Units 115 Condensing Unit Indoor UNSchematic DFF2AH09J1A, DFF2AH12J1A FAN Coil with D O O R U N I TSTART-UP Care and MaintenanceService Indoor UnitLamp Status Indication Correction Action Troubleshooting Tables 6-8, and FigService Indicators Tempeature Temperature Minimum Mean 100.4 General System Troubleshooting Guide