Danby DPAC5009 manual Operation, Remote Control Features

Page 6

OPERATION

REMOTE CONTROL FEATURES:

POWER CONTROL: The power control turns the unit on and off.

MODE CONTROL: The mode control has 4 settings: Cool, Dehumidifiy, Fan, Auto. The settings are adjustabed by the Mode Control button.

COOLING MODE: During the cooling mode, the air is cooled and hot air is exhausted outside through the exhaust tube. Adjust fan speed and temper- ature to suit your desired comfort level.

Note: The air exchange hoses must vent outside the room when using Cool mode.

DEHUMIDIFY MODE: Air is dehumidified as it passes through the air conditioner, without being in full cooling mode. If room temperatures is higher than 25°C (77°F), fan speed can be adjusted;

otherwise fan speed is fixed to “low”.

FAN MODE: Air is circulated throughout the room with no cooling.

Note: Unit does not need to be vented in Fan mode.

AUTO MODE: In auto mode the unit will switch mode and fan speed automatically based on the ambient temperature.

LCD DISPLAY FEATURES:

On/Off

Switch

LCD

Display

FAN SPEED CONTROL: The fan speed control has 4 settings: Auto (Cooling only), High, Medium, and Low.

TEMP. SET CONTROLS :

The temperature can be set by means of the and

buttons on the remote control. The temperature can be set between 16°C (61°F ) and 32°C (89°F). Pressing the and buttons will cause the set temperature to remain in the display panel for approximately 5 seconds. The display will then revert back to showing the current room temperature.

Note: It is only possible to set the temperature when in COOLING MODE. The temperature can not be set when in AUTO, DEHUMIDIFYING or FAN mode.

FAHRENHEIT / CELSIUS SELECTOR: Pressing this button will switch the display between degrees Celsius and degrees Fahrenheit. Note: Initial setting is °C

TIMER SETTING CONTROL: Press the Timer button on the remote control to set the timer. The ON or OFF logos (depending on timer modes “A” or “B” below) will appear in the display panel, and the clock symbol will flash for approx. 10 seconds; the display panel will show a time of 8 hrs. While the clock symbol is flashing, press the and buttons on the remote control to select the time (in hours between 00 and 24) for either of the timer modes “A” or “B” (see below). The time selected will be shown on the display panel and after approximately 10 seconds, the clock symbol will remain illuminated together with either the ON or OFF logo.

Timer Mode A) Auto Turn Off: With the machine on and running, set the timer to select the number of hours you would like the unit to run until it automatically shuts off. The set time will be shown in the display together with the clock symbol and the OFF logo.

Tiimer Mode B) Auto Turn On: Switch the machine on using the ON / OFF button (either on the machine itself or on the remote control) so that the machine is running and the desired mode is selected. Press the ON/OFF button again to put the machine into stand-by mode. Set the timer to select the number of hours until it is required for the machine to start up automatically. The set time will be shown in the display together with the clock symbol and the ON logo.

TIMER CANCEL CONTROL: If the time has been set as in either “A” or “B” above and it is then decided that the timer is not required, pressing the CANCEL button will turn the timer off.

LCD DISPLAY SYMBOLS:

Auto mode

Cooling mode

Dehumidify mode

Fan only mode

High fan speed

Med. fan speed

Low fan speed

Display set temperature

Display timer setting of auto switch on/off

5

Image 6
Contents Model Modèle DPAC5009 Keep These Instructions for Future ReferenceConserver CES Instructions Pour Consultation Ultérieur Welcome Important Safety Information Electrical SpecificationsPower ENERGY-SAVING Important Safety Information cont’dFeatures TipsInstallation Window KIT InstallationInstructions for Assembling the Window Kit- Fig Remote Control Features OperationFAN Operation cont’dAIR Conditioner DehumidifierAUTO-TIMER Timer Setting ControlTimer Cancel Control Care and Maintenance Cleaning UnitCleaning Troubleshooting Problem Possible Cause SolutionsBienvenue 800-26Tableau Consignes DE Sécurité ImportantSpécifications Électriques CordonÉconomiseur Consignes DE Sécurité Important suiteCaractéristiques ’ENERGIEInstallation DU KIT DE Fenêtre Mode Climatisation SeulementCharacteristiques DE Télécommande FonctionnementVentilateur Fonctionnement suiteClimatiseur DéshumidificateurMode de temporisateur B Marche Automatique Commande Programmation TemporisateurMode de temporisateur a Arrêt Automatique Commande Annulation TemporisateurNettoyage DES Soins ET EntretienNettoyage DE L’UNITÉ Pourrait causer des dommages à l’unitéProbleme Cause Probable Solution DépannageModel Modèle DPAC5009