Danby DPAC5009 manual Operation cont’d, AIR Conditioner, Fan, Dehumidifier

Page 7

OPERATION (cont’d)

AIR CONDITIONER

Note: The exhaust hose must be properly vented (outdoors) during air conditioning mode.

1)Press the POWER SWITCH key (Fig. A) to switch on the unit, and the previous set temperature will be shown in the temperature display area of the control panel.

Fig. A

2)Press the MODE key (Fig. B) until the COOL indicator light illuminates on the control panel (Fig. C). Each depression of the MODE key will advance to a different mode setting (Cool - Dehumidifier - Fan)

3)Press the appropriate increase or decrease buttons (Fig. D) to select a suitable operating temperature setting. Temperature settings are adjustable between 16°C (61°F) to 32°C (89°F).

4)Press the FAN key (Fig. E) to select the desired fan speed setting (Auto High- Med-Low). Your selection will appear on the control panel (each depression of

the fan key will advance to a different setting).

Cooling stops automatically when the set temperature is achieved. Cooling resumes when the room temperature rises above the “set” temperature level.

FAN

Note: During Fan mode, the exhaust hose does not have to be vented outdoors.

1)Press the POWER SWITCH key pad to switch on the unit (Fig. A).

2)Press the MODE key (Fig. B) until the FAN indicator illuminates on the control panel (Fig. G). Each depression of the MODE key will advance to a different mode setting (Cool-Dehumidifier-Fan).

3)Press the Fan key (Fig. E) to select the desired FAN SPEED setting. Your selection will appear on the control panel. Each depression of the fan key will advance to a different fan speed (High-Med.-Low) as shown in Fig. F.

DEHUMIDIFIER

Note: During dehumidifier mode, the exhaust hose does not have to be vented outdoors.

1)Press the POWER SWITCH key pad to switch on the unit (Fig. A)

2)Press the MODE key (Fig. B) until the DRY indicator illuminates on the control panel (Fig. H). Each depression of the MODE key will advance to a different mode setting (Cool-Dehumidifier-Fan).

IMPORTANT: There is no temperature adjustment during dehumidifier mode. If the room temperature is greater than 25°C, the fan speed can be adjusted, otherwise the fan speed is fixed at LOW speed.

Fig. B

Fig. C

Fig. D

Fig. E

Fig. F

Fig. G

Fig. H

6

Image 7
Contents Keep These Instructions for Future Reference Model Modèle DPAC5009Conserver CES Instructions Pour Consultation Ultérieur Welcome Electrical Specifications Important Safety InformationPower Tips Important Safety Information cont’dFeatures ENERGY-SAVINGWindow KIT Installation InstallationInstructions for Assembling the Window Kit- Fig Operation Remote Control FeaturesDehumidifier Operation cont’dAIR Conditioner FANTimer Setting Control AUTO-TIMERTimer Cancel Control Cleaning Unit Care and MaintenanceCleaning Problem Possible Cause Solutions Troubleshooting800-26 BienvenueCordon Consignes DE Sécurité ImportantSpécifications Électriques Tableau’ENERGIE Consignes DE Sécurité Important suiteCaractéristiques ÉconomiseurMode Climatisation Seulement Installation DU KIT DE FenêtreFonctionnement Characteristiques DE TélécommandeDéshumidificateur Fonctionnement suiteClimatiseur VentilateurCommande Annulation Temporisateur Commande Programmation TemporisateurMode de temporisateur a Arrêt Automatique Mode de temporisateur B Marche AutomatiquePourrait causer des dommages à l’unité Soins ET EntretienNettoyage DE L’UNITÉ Nettoyage DESDépannage Probleme Cause Probable SolutionModel Modèle DPAC5009