Danby DPAC7099 Troubleshooting, Problem Possible Cause, Solution, Unit does not work Power is out

Page 12

TROUBLESHOOTING

Occasionally, a problem may occur that is minor, and a service call may not be necessary. Use this troubleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or Danby’s Toll Free Number for assistance.

PROBLEM

POSSIBLE CAUSE

• Unit does not work

• Power is out

The plug is not plugged in properly

The full-tank indicator is ON; tank is full

Current leaking or pressing test button on LCDI plug

• Unit suddenly stops during

• Indoor set temperature has been

operation

reached

 

• The preset time is up

 

• The full-tank indicator is ON; tank is

 

full

• Unit runs intermittently

• Malfunction

 

• Surrounding temperature is too

 

high/low

 

• Exhaust duct hose is blocked

• Unit functions but the room

• Window or door is open in room

is not cooled

• There is a heat source or too many

 

people in the room

 

• Air intake grill is clogged

 

• Filter is too dirty

 

• Temperature setting is too high

• Condensed water spills out

• The tank is nearly full

when moving the unit

 

SOLUTION

Wait for power to return

Plug in properly

Remove drain water from the drain tank

Press the reset button after resolving problem

Reset the temperature level

Reset the timer

Remove drain water from the drain tank

Contact your dealer

This is normal

Check the duct hose

Close all windows/doors

Move any heat sources from room

Clean air intake grill

Replace the filter

Lower temp. setting

Remove drain plug on rear bottom and drain out water

11

Image 12
Contents Dpac Climatiseur PortatifTable of Contents Unit Specifications WelcomeImportant Safety Information Electrical SpecificationsPart Identification Cord ENERGY-SAVINGTips Your Danby appliance is designed to be highly efficientInstallation Installation AccessoriesAir Conditioning Mode only Window KITOPERATION- Features of the Control Panel Water Full IndicatorLCD Display Remote Control Operating Instructions Draining Excess WaterAIR Conditioning Operating Instructions cont’d DehumidifierFAN Care and Maintenance Cleaning UnitFilter Troubleshooting Problem Possible CauseSolution Unit does not work Power is outTable DES Matières Spécifications DE L’UNITÉ Identification DE PartieSoins ET Entretien Bienvenue Spécifications DE L’UNITÉIdentification DE Partie Consignes DE Sécurité ImportantSpécifications Électriques TableauCordon Suggestions PourVentilateur à la position Haute Mode Climatisation Seulement KIT DE FenêtreFerrure Fenêtre HorizontaleOPÉRATION- Dispositifs de Panneau de Commande Plein Indicateur DE LeauTélécommande Fonctionnement Vindage DE ’EXÉS D’EAUFonctionnement suite VentilateurSoins ET Entretien Nettoyage DE LunitéNettoyage DES Probleme Cause Probable DépannageLunité ne fonctionne pas Il ny a pas dalimentation