Power Control

The Power Control turns the unit on and off

Mode Control

The Mode Control has 4 settings:

• Cool • Dehumidify • Fan • Auto

The settings are adjusted by the Mode Control button

• Cooling Mode

During the cooling mode the air is cooled and hot air is exhausted outside through the exhaust tube. Adjust fan speed and temperature to suit your desired comfort level.

Note: The air exchange hoses must vent outside the room when using Cool Mode.

• Dehumidify Mode

Air is dehumidified as it passes through the air conditioner, without being in full cooling mode. If room temperature is higher than 25°C (77°F), fan speed can be adjusted; otherwise fan speed is fixed to low.

Note: If the unit is to be used as a dehumidifier, do not connect the exhaust hose to vent outside. When using as a dehumidifier, continuous drainage is necessary.

• Fan Mode

Air is circulated throughout the room with no cooling.

Note: Unit does not need to be vented in Fan Mode.

• Auto Mode

In Auto Mode the unit swill switch its mode and fan speed automatically based on the ambient temperature.

Fan Speed Control

The Fan Speed Control has 4 settings:

• Auto (Cooling only) • High • Medium • Low

Temp. Set Controls &

The temperature can be set by means of the and buttons on the remote control. The temperature can be set between 16°C (61°F) and 32°C (89°F), and pressing the and buttons will cause the set temperature to remain in the display panel for approximately 5 seconds. The display will then revert back to showing the current room temperature.

Note: It is only possible to set the temperature when in Cooling Mode. The temperature cannot be set when in Auto, Dehumidify, or Fan mode.

Fahrenheit/Celsius Selector Pressing this button will switch the display between degrees Celsius and degrees Fahrenheit.

Note: Initial setting is °C

Timer Setting Control

Press the Timer button on the remote control to set the timer. The “ON” or “OFF” logos (depending on timer modes “A” or “B” below) will appear in the display panel, the clock symbol will flash for approximately 10 seconds, and the display panel will show the time of 8 hrs. While the clock symbol is flashing, press the and buttons on the remote control to select the time (in hours, between 00 and 24) for either of the timer modes “A” or “B” as detailed below. The time selected will be shown on the display panel and after approximately 10 seconds the clock symbol will remain illuminated together with either the “ON” or “OFF” logo.

Timer Mode A) Auto Off:

With the machine on and running, set the timer to select the number of hours you would like the unit to run until it automatically shuts off. The set time will be shown in the display together with the clock symbol and “OFF” logo.

Timer Mode B) Auto On:

Switch the machine on using the ON/OFF button (either on the machine itself or on the remote control) so that the machine is running and the desired mode is selected. Press the ON/OFF button again to put the machine in stand-by mode. Set the timer to select the number of hours until it is required for the unit to start up automatically. The set time will be shown in the display together with the clock symbol and the “ON” logo.

Timer Cancel Control

If the time has been set as in either “A” or “B” above and it is then decided that the timer is not required, pressing the CANCEL button will turn the timer off.

7

Image 8
Contents Dpac Climatiseur PortatifTable of Contents Unit Specifications WelcomePart Identification Important Safety InformationElectrical Specifications Cord ENERGY-SAVINGTips Your Danby appliance is designed to be highly efficientInstallation Installation AccessoriesAir Conditioning Mode only Window KITLCD Display OPERATION- Features of the Control PanelWater Full Indicator Remote Control AIR Conditioning Operating InstructionsDraining Excess Water FAN Operating Instructions cont’dDehumidifier Filter Care and MaintenanceCleaning Unit Troubleshooting Problem Possible CauseSolution Unit does not work Power is outSoins ET Entretien Table DES MatièresSpécifications DE L’UNITÉ Identification DE Partie Bienvenue Spécifications DE L’UNITÉIdentification DE Partie Consignes DE Sécurité ImportantSpécifications Électriques TableauVentilateur à la position Haute CordonSuggestions Pour Mode Climatisation Seulement KIT DE FenêtreFerrure Fenêtre HorizontaleOPÉRATION- Dispositifs de Panneau de Commande Plein Indicateur DE LeauTélécommande Fonctionnement Vindage DE ’EXÉS D’EAUFonctionnement suite VentilateurNettoyage DES Soins ET EntretienNettoyage DE Lunité Lunité ne fonctionne pas Il ny a pas dalimentation Probleme Cause ProbableDépannage