Danby DPAC7099 Operating Instructions, Draining Excess Water, AIR Conditioning

Page 9

OPERATING INSTRUCTIONS

DRAINING

EXCESS WATER

1)Drain excess water from the tank by placing a pan under the drain water outlet (Fig. 4)

2)Remove the drain plug and let the water drain into the pan.

3)When the water stops draining out, replace the drain plug, and put the tube back in with the clip pointing up.

4)Remove the pan of water.

5)Operate the unit in Fan mode to dry the interior of the unit.

Fig. 4

AIR CONDITIONING

Important: The exhaust hose must be properly vented outdoors during air conditioning mode.

1)Press the POWER SWITCH key (Fig. A) to switch the unit on, and the previous set temperature will be shown in the temperature display area of the control panel.

Fig. A

2)Press the MODE key (Fig. B) until the COOL indicator light illuminates on the control panel (Fig. C). Each depression of

the MODE key will advance to a different mode setting

(Cool- Dehumidify- Fan- Auto )

3)Press the appropriate increase or decrease buttons (Fig. D) to select a suitable operating temperature setting. Temperature settings are adjustable between 16°C (61°F) to 32°C (89°F)

4)Press the FAN key (Fig. E) to select the desired fan speed setting (High - Med.- Low- Auto ). Your selection will appear on the control panel (each depression of the fan key will advance to a different setting as shown in Fig. F).

Cooling stops automatically when the set temperature is achieved. Cooling resumes when the room temperature rises above the set temperature level.

Fig. B

Fig. C

Fig. D

Fig. E

Fig. F

8

Image 9
Contents Climatiseur Portatif DpacTable of Contents Welcome Unit SpecificationsImportant Safety Information Electrical SpecificationsPart Identification ENERGY-SAVING CordTips Your Danby appliance is designed to be highly efficientInstallation Accessories InstallationAir Conditioning Mode only Window KITOPERATION- Features of the Control Panel Water Full IndicatorLCD Display Remote Control Operating Instructions Draining Excess WaterAIR Conditioning Operating Instructions cont’d DehumidifierFAN Care and Maintenance Cleaning UnitFilter Problem Possible Cause TroubleshootingSolution Unit does not work Power is outTable DES Matières Spécifications DE L’UNITÉ Identification DE PartieSoins ET Entretien Spécifications DE L’UNITÉ BienvenueConsignes DE Sécurité Important Identification DE PartieSpécifications Électriques TableauCordon Suggestions PourVentilateur à la position Haute KIT DE Fenêtre Mode Climatisation SeulementFerrure Fenêtre HorizontalePlein Indicateur DE Leau OPÉRATION- Dispositifs de Panneau de CommandeTélécommande Vindage DE ’EXÉS D’EAU FonctionnementVentilateur Fonctionnement suiteSoins ET Entretien Nettoyage DE LunitéNettoyage DES Probleme Cause Probable DépannageLunité ne fonctionne pas Il ny a pas dalimentation