ResMed III user manual Menu Functions Detailed menu only, Settings Menu

Page 29

To access the VPAP menus:

Press the Left key (menu) while the VPAP (or Ramp) screen is displayed.

To scroll through items within a menu or submenu: Press the Up/Down key

To enter a submenu: Press the Left key (enter).

To change a setting option for a function:

1.Press the Left key (change)

2.Press the Up/Down key until the desired setting option appears.

3.Press the Left key (apply) to select the setting option.

To exit without changing options: Press the Right key (cancel)

To exit out of a menu or submenu: Press the Right key (exit)

Note: You can return to the VPAP (or Ramp) screen at any time by holding the Right key for at least three seconds.

Menu Functions (Detailed menu only)

The VPAP menu functions are summarised in Tables 2–6 below with a brief description of what each function does and the available setting options. To access these functions, see “How to Use the Detailed Menu (if enabled by your clinician)” on page 20.

Settings Menu

The Settings Menu allows you to view and change certain operating features of the VPAP unit.

Table 2: Settings Menu Functions

Function

Default

Function Description

Setting Options

 

 

 

 

Mask

ULTRA

Selects your mask type.

See “Settings for

 

 

 

Mask Types” on

 

 

 

page 23 for details.

 

 

 

 

Tube Length

2m

Selects the length of air tubing

2m / 3m

 

 

connecting your mask to the

 

 

 

VPAP.

 

 

 

 

 

22

Image 29
Contents 248127/1 05 Illustrations 52 cm 3 m English Manufactured by Contents Limited Warranty Index Medical Information IntroductionUser/Owner Responsibility What the Vpap III and Vpap III ST are Intended forPage Medical Information Adverse EffectsPage Masks Vpap SystemHumidifiers AccessoriesAttaching a Humidifier Setting up the Vpap SystemSetting Up The Vpap Attaching a HumidAire Humidifier Attaching a HumidAire 2i HumidifierAttaching a HumidAire 2iC Humidifier Attaching a Passover Humidifier LCD Screen Using the LCD Screen and KeypadKeypad Keys KeyFunction FrontRight red Key Function Left greenPage Starting Treatment Starting TreatmentRamp time Stopping Treatment Using the HumidAire 2i Warm-Up FeatureUsing the Mask-Fitting Feature High Leak Page Daily Cleaning Cleaning and MaintenanceWeekly Cleaning Periodic CleaningServicing Replacing the Air FilterRamp Screen How to Use the Vpap MenusHow to Use the Standard Menu To exit out of the menu Press the Right key exit How to Use the Detailed Menu if enabled by your clinicianVpap Detailed Menu Series if enabled by your clinician To enter a submenu Press the Left key enter Settings MenuMenu Functions Detailed menu only Settings for mask types Mask Function Default Function Description Setting OptionsResults Menu Settings MaskResults Menu Function Function Description Setting Options Servicing Menu Options MenuTreatment screen Treatment ScreensHow to Use the Vpap Menus Page Helpful Hints Using a Battery and an InverterStarting out Nasal IrritationPage Troubleshooting TroubleshootingCheck tube Key if done Problem Possible Cause SolutionLast session Page Dynamic pressure characteristics System SpecificationsFlow sensor in flow generator IEC 60601-1 ClassificationsPressure Variation Pressure Volume curvePressure cm H2O BreathsEnvironmental information Symbols which appear on the productEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Limited WarrantyProduct Warranty Period Page Index