ResMed III user manual Stopping Treatment, Using the HumidAire 2i Warm-Up Feature

Page 21

Stopping Treatment

To stop treatment at any time, remove your mask and press the Front key

or

if your clinician has enabled the SmartStart function, simply remove your mask and treatment will end (SmartStop is not applicable with the "Mir Full" mask setting).

Using the HumidAire 2i Warm-Up Feature

If using a HumidAire 2i with the VPAP, you can use the Warm-Up feature to pre-heat the water in the humidifier prior to starting treatment.

After stopping treatment, the VPAP will continue to blow air gently to assist cooling of the heater plate.

See the HumidAire 2i User’s Manual for further details.

Using the Mask-Fitting Feature

The VPAP Mask-Fitting feature can be used to help you fit your mask properly. The mask-fitting feature delivers air pressure for a three-minute period, prior to starting treatment, for checking and adjusting your mask fit to minimise leaks. If a Ramp time is selected, the mask can be adjusted at a pressure closer to the prescribed pressure. To use the mask-fitting feature:

1.Fit your mask as described in the user instructions.

2.Hold down the Front key for at least three seconds until air pressure delivery starts.

The following display will appear on the LCD screen indicating that the Mask-Fitting feature is in operation. The flow generator will ramp to the Mask-Fit pressure and will remain at this pressure for three minutes. A Mask-Fit star rating is also displayed. See “Definitions of Mask-Fit Star Rating” on page 15.

Mask Fit

*****

 

 

Mask-Fit Star rating

 

 

excelnt

 

 

 

 

 

 

 

 

Notes:

The Mask-Fit star rating display disappears after three minutes.

The Mask-Fitting feature can only be started from the VPAP (or Ramp) screen.

The Mask-Fit pressure is the set treatment pressure or 10 cm H20, whichever is greater.

3.Adjust your mask, mask cushion and headgear until you have a secure and comfortable fit.

14

Image 21
Contents 248127/1 05 Illustrations 52 cm 3 m English Manufactured by Contents Limited Warranty Index Medical Information IntroductionUser/Owner Responsibility What the Vpap III and Vpap III ST are Intended forPage Medical Information Adverse EffectsPage Masks Vpap SystemHumidifiers AccessoriesSetting up the Vpap System Setting Up The VpapAttaching a Humidifier Attaching a HumidAire 2i Humidifier Attaching a HumidAire 2iC HumidifierAttaching a HumidAire Humidifier Attaching a Passover Humidifier LCD Screen Using the LCD Screen and KeypadKeypad Keys KeyFunction FrontRight red Key Function Left greenPage Starting Treatment Ramp timeStarting Treatment Using the HumidAire 2i Warm-Up Feature Using the Mask-Fitting FeatureStopping Treatment High Leak Page Daily Cleaning Cleaning and MaintenanceWeekly Cleaning Periodic CleaningServicing Replacing the Air FilterHow to Use the Vpap Menus How to Use the Standard MenuRamp Screen To exit out of the menu Press the Right key exit How to Use the Detailed Menu if enabled by your clinicianVpap Detailed Menu Series if enabled by your clinician Settings Menu Menu Functions Detailed menu onlyTo enter a submenu Press the Left key enter Settings for mask types Mask Function Default Function Description Setting OptionsSettings Mask Results Menu Function Function Description Setting OptionsResults Menu Servicing Menu Options MenuTreatment screen Treatment ScreensHow to Use the Vpap Menus Page Helpful Hints Using a Battery and an InverterStarting out Nasal IrritationPage Troubleshooting TroubleshootingCheck tube Key if done Problem Possible Cause SolutionLast session Page Dynamic pressure characteristics System SpecificationsFlow sensor in flow generator IEC 60601-1 ClassificationsPressure Variation Pressure Volume curvePressure cm H2O BreathsEnvironmental information Symbols which appear on the productEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Product Warranty PeriodLimited Warranty Page Index