Skuttle Indoor Air Quality Products 60-2, F60-2 warranty Option C Duct Center Mount

Page 14

Option C: Duct Center Mount

Figure 3 – Duct Center Mount

Option C requires duct reinforcement to hold the humidifier securely in place (see Figure 3).

DANGER: Wear safety glasses when cutting or drilling. Do not cut into any air conditioning or electrical accessories during installation.

Electrocution is possible if you come in contact with a live electrical wire; blindness can occur if Freon contacts your eyes.

To install:

1.Attach the humidifier mounting template to the selected location on the bottom of the duct.

2.Drill two (2) holes marked “B” with a 7/64" drill bit. Drill a hole in the center of the shaded area of the template and remove the shaded area using tin snips.

CAUTION: Follow the dotted line carefully.

3.Remove the template.

4.Cut two (2) pieces of S-Cleat 8" long and one (1) piece 10-1/2" long.

14

Image 14
Contents Skuttle Homeowner Wiring without Air Conditioning External Relay Warranty Validation Skuttle Limited One-Year Product Warranty Page How to Install a Skuttle Model 60-Series Steam Humidifier Safety PrecautionsTools and Materials Needed Selecting a Location Mounting the Humidifier Contractor Option B External Side Mount Contractor Option C Duct Center Mount Contractor Option D Internal Side Mount Contractor Connecting to a Power Source Wiring the Air Mover Page Wiring the Fan Switch Plumbing and Setting the Water Level Lowering the Water Level Page How To Maintain a Skuttle Steam Humidifier Page Trouble Shooting See Plumbing and Setting WaterReplacement Parts Models 60-1 and F60-1Models 60-2 and F60-2 Maintenance Record Homeowner How Your Humidifier WorksHow To Extend the Life of Your Humidifier FAQs about IAQ General InfoShould I run my humidifier during the summer months? Skuttle Automatic Flushing Timer Skuttle Model 216 Make-Up Air Control Skuttle High-Efficiency Air Cleaners Help Homeowners Breathe Easier Skuttle Air CleanersFiltration Skuttle Happy House Your Assurance of Enhanced IAQHumidification Ventilation Skuttle