Figure 8B - Typical wiring for a humidifier in a single-speed air mover application without air conditioning (switching through a G contactor).

Wiring the Fan Switch

For heat pump installations, because of the near-continuous operation of the system air mover, we suggest that installation of a fan sail switch or Skuttle A50 relay be the only additional wiring you perform.

The switch or relay needs to be wired in series with the low-voltage humidity control circuit in order to allow operation of the humidifier during fan operation only (see “NOTE” immediately following this paragraph). In most cases, the humidifier will operate in conjunction with the system air mover to adequately humidify the home.

NOTE: Due to the wiring complexity and multiple variations of heat pumps, it is impossible to provide appropriate diagrams. If you plan for the humidifier to control air mover operation, it is the responsibility of the installing contractor to design a safe control circuit by following diagrams provided with the equipment.

21

Image 21
Contents Skuttle Homeowner Wiring without Air Conditioning External Relay Warranty Validation Skuttle Limited One-Year Product Warranty Page Safety Precautions How to Install a Skuttle Model 60-Series Steam HumidifierTools and Materials Needed Selecting a Location Mounting the Humidifier Contractor Option B External Side Mount Contractor Option C Duct Center Mount Contractor Option D Internal Side Mount Contractor Connecting to a Power Source Wiring the Air Mover Page Wiring the Fan Switch Plumbing and Setting the Water Level Lowering the Water Level Page How To Maintain a Skuttle Steam Humidifier Page See Plumbing and Setting Water Trouble ShootingModels 60-1 and F60-1 Replacement PartsModels 60-2 and F60-2 Maintenance Record How Your Humidifier Works HomeownerHow To Extend the Life of Your Humidifier General Info FAQs about IAQShould I run my humidifier during the summer months? Skuttle Automatic Flushing Timer Skuttle Model 216 Make-Up Air Control Help Homeowners Breathe Easier Skuttle Air Cleaners Skuttle High-Efficiency Air CleanersSkuttle Happy House Your Assurance of Enhanced IAQ HumidificationFiltration Ventilation Skuttle