Ruud AP13370-2 installation instructions Water Temperature Setting

Page 4

IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.

! DANGER!

WATER TEMPERATURE SETTING

Safety and energy conservation are factors to be considered when selecting the water temperature setting of a water heater’s gas control. Water temperatures above 125°F (52°C) can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. This label is also located on the water heater.

!D A N G E R

HOT

BURN

Water temperature over 125°F can cause severe burns instantly or death from scalds.

Children, disabled and elderly are at highest risk of being scalded.

See instruction manual before setting temperature at water heater.

Feel water before bathing or showering.

Temperature limiting valves are available, see manual.

Notice: Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines. Contact a licensed plumber or the local plumbing authority for further information.

Time/Temperature Relationship in Scalds

Water Temperature

Time To Produce a Serious Burn

120°F (49°C)

More than 5 minutes

125°F (52°C)

11/2 to 2 minutes

130°F (54°C)

About 30 seconds

135°F (57°C)

About 10 seconds

140°F (60°C)

Less than 5 seconds

145°F (63°C)

Less than 3 seconds

150°F (66°C)

About 11/2 seconds

155°F (68°C)

About 1 second

Table courtesy of Shriners Burn Institute

The chart shown above may be used as a guide

in determining the proper water temperature for your home.

!DANGER: Households with small children, disabled,

or elderly persons may require a 120°F (49°C) or lower gas control (thermostat) setting to prevent contact with “HOT” water.

Maximum water temperatures occur just after the burner has shut off. To find water temperature being delivered, turn on a hot water faucet and place a thermometer in the water stream and read the thermometer.(See page 21 and 22 for more details.)

The temperature of the water in the heater can be regulated by setting the temperature dial on the front of the gas control (thermostat). To comply with safety regulations the gas control(thermostat) was set at its lowest setting before the water heater was shipped from the factory.

 

120°F (49°C)

115°F (46°C)

 

 

 

125°F (52°C)

 

 

 

110°F

 

130°F (54°C)

(43°C)

 

135°F (57°C)

105°F

 

 

 

 

(41°C)

 

140°F (60°C)

100°F

 

 

 

145°F (63°C)

(38°C)

 

 

 

150°F (66°C)

95°F

 

(35°C)

 

 

 

155°F (68°C)

68°F (20°C)

 

(Vacation Setting)

 

 

4

160°F (71°C)

Temperatures are approximate

 

 

The illustration at the left details the approximate water temperature

for each mark on the Gas Control (Thermostat) Temperature Dial.

!DANGER: Hotter water increases the potential for Hot Water

SCALDS.

Image 4
Contents Water Heaters For Your Records N G E R Water Temperature Setting Page Read and Follow this Safety Information Carefully Installing the water heater LocationCombustion and Ventilation Air Inspect ShipmentCorrosive Atmospheres Venting Horizontal Vent Terminal Location Blower Assembly InstallationAdditional Considerations Joining Pipes and Fittings Minimum and Maximum Vent LengthCementing Joints Vertical Vent Termination Horizontal Vent InstallationDraining the Condensate Water Supply Connections Thermal ExpansionRelief Valve Leak Testing To Fill the Water HeaterCondensation Gas SupplyWiring Pressure Testing the Gas Supply SystemHigh Altitude Insulation Blankets Hot and Cold Pipe Insulation InstallationHeat Trap Typical Installation Water Heater Location Installation ChecklistWater Supply Combination Potable and Space Heating Application Lighting the water heater Water Temperature Setting AdjustmentsOperating the water heater Water Temperature Setting… Draining the Water Heater Routine Preventative MaintenanceHousekeeping Venting System Inspection Burner InspectionVacation and Extended Shut-Down Anode RodBefore You Call For Service… Problem Possible Causes What To DoGas Valve Error Code Table No hot water Exceeded the capacity Water heaterReplacement Parts Instructions For Placing a Parts OrderIf YOU Need Service

AP13370-2 specifications

The Ruud AP13370-2 is a high-performance air conditioning unit designed for both residential and commercial spaces, delivering efficient cooling and heating solutions. This model stands out for its advanced technology and user-friendly features, making it a favored choice among consumers seeking comfort and reliability.

One of the main features of the Ruud AP13370-2 is its Energy Efficiency Ratio (EER), which ensures lower energy consumption while providing optimal cooling performance. With its high SEER (Seasonal Energy Efficiency Ratio) rating, the unit is designed to operate with minimal energy usage, thus reducing electricity bills and environmental impact. This efficiency is crucial for eco-conscious homeowners and business operators.

The AP13370-2 integrates innovative inverter technology, allowing for variable speed operation. This technology adjusts the compressor speed to match the desired temperature, providing more precise climate control and reducing noise levels. Consequently, users can enjoy a quieter indoor environment without sacrificing comfort.

In addition to its energy-saving capabilities, the Ruud AP13370-2 is equipped with advanced filtration systems. These filters capture dust, allergens, and other pollutants, enhancing indoor air quality. This is particularly beneficial for individuals with allergies or respiratory issues. The filtration system is designed for easy maintenance, allowing users to replace or clean filters effortlessly.

Moreover, the unit supports smart home integration, enabling remote control through mobile devices or smart speakers. Users can adjust the settings, schedule operations, and monitor energy usage conveniently, fostering a seamless user experience. This feature is especially valuable for those with busy lifestyles, allowing for efficient climate management even when away from home.

Durability is another important characteristic of the Ruud AP13370-2. Constructed with high-quality materials, it is built to withstand varying weather conditions, ensuring longevity and reliability over time. The unit also features a comprehensive warranty, providing users with peace of mind.

Overall, the Ruud AP13370-2 air conditioning unit combines efficiency, technology, and user-friendly features. Its commitment to energy savings, air quality improvement, and smart technology integration makes it an excellent choice for anyone looking to enhance their indoor climate while minimizing their environmental footprint. Whether for home or business use, the AP13370-2 stands as a testament to modern HVAC design and engineering.