Ruud AP13370-2 installation instructions Water Temperature Setting…

Page 22

Operating the water heater.

Water Temperature Setting…

Maximum water temperatures occur just after the burner has shut off. To determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream.

The wide arrow mark near CAUTION on the rim of the temperature dial, represents an approximate water temperature of 120°F (49°C).

The reference mark, to the left, represents an approximate water temperature of 125°F (52°C).

Each reference mark above or below these points indicates an approximate change of 5°F (3°C).

To adjust the temperature, turn the temperature dial to an initial setting of 120°F (49°C).

A condition known as “stacking” or “layering” can occur when a series of short and frequent hot water draws are taken.

The hottest temperature water will be at the top of the tank, closest to the outlet pipe delivering hot water to the home.

Stacking can cause this top layer of water to be hotter than the water toward the bottom of the tank near the gas control (thermostat).

Therefore, always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury.

Also, always supervise young children or others who are incapacitated.

The gas control (thermostat) is constructed with a built in safety shut-off device designed to shut off the gas supply to the burner if the pilot flame is extinguished for any reason.

The gas control (thermostat) is also equipped with a single use gas shut off device that will shut off the gas supply to the burner if the water heater exceeds normal operating temperatures. Refer to the (Before You Call For Service) section of this manual, or contact your dealer.

!WARNING: Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

If the water heater has been subjected to fire, flood or physical damage, turn off the manual gas control (shut-off) valve, and do not operate the water heater again until it has been checked by qualified personnel.

120°F (49°C)

115°F (46°C)

Time/Temperature Relationship in Scalds

 

 

 

 

 

125°F (52°C)

 

Water Temperature

Time To Produce a Serious Burn

 

110°F

20°F (49°C)

More than 5 minutes

130°F (54°C)

(43°C)

125°F (52°C)

11/2 to 2 minutes

 

 

135°F (57°C)

105°F

130°F (54°C)

About 30 seconds

 

 

 

135°F (57°C)

About 10 seconds

 

(41°C)

 

 

 

140°F (60°C)

 

140°F (60°C)

Less than 5 seconds

100°F

145°F (63°C)

Less than 3 seconds

 

145°F (63°C)

(38°C)

150°F (66°C)

About 11/2 seconds

 

 

 

 

95°F

155°F (68°C)

About 1 second

150°F (66°C)

 

 

(35°C)

Table courtesy of Shriners Burn Institute

 

 

 

155°F (68°C)

68°F (20°C)

 

 

(Vacation Setting)

 

 

 

 

 

160°F (71°C)

Temperatures are approximate

 

 

 

 

 

22

Image 22
Contents Water Heaters For Your Records N G E R Water Temperature Setting Page Read and Follow this Safety Information Carefully Installing the water heater LocationCombustion and Ventilation Air Inspect ShipmentCorrosive Atmospheres Venting Horizontal Vent Terminal Location Blower Assembly InstallationAdditional Considerations Joining Pipes and Fittings Minimum and Maximum Vent LengthCementing Joints Vertical Vent Termination Horizontal Vent InstallationDraining the Condensate Water Supply Connections Thermal ExpansionRelief Valve Condensation Leak TestingTo Fill the Water Heater Gas SupplyWiring Pressure Testing the Gas Supply SystemHigh Altitude Insulation Blankets Hot and Cold Pipe Insulation InstallationHeat Trap Typical Installation Water Heater Location Installation ChecklistWater Supply Combination Potable and Space Heating Application Lighting the water heater Water Temperature Setting AdjustmentsOperating the water heater Water Temperature Setting… Draining the Water Heater Routine Preventative MaintenanceHousekeeping Vacation and Extended Shut-Down Venting System InspectionBurner Inspection Anode RodBefore You Call For Service… Problem Possible Causes What To DoGas Valve Error Code Table No hot water Exceeded the capacity Water heaterReplacement Parts Instructions For Placing a Parts OrderIf YOU Need Service