*UH2C100A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
|
|
|
|
|
|
|
|
|
|
|
| 1st Stage Capacity = | 62,855 |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| 2nd Stage Capacity = | 96,700 |
|
|
|
|
|
|
| ||
|
| AIRFLOW | DIP SWITCH SETTING |
|
|
|
|
| EXTERNAL STATIC PRESSURE |
|
| |||||||||||
|
| SETTING |
| SW 7 |
| SW8 |
|
|
|
| 0.1 | 0.3 | 0.5 |
| 0.7 |
|
| 0.9 |
| |||
|
|
|
|
|
|
|
|
| CFM |
| 873 | 893 | 900 |
| 899 |
|
| 902 |
| |||
|
| LOW |
| ON |
| ON | TEMP. RISE |
| 64 | 63 | 62 |
| 62 |
|
| 62 |
| |||||
|
|
|
|
|
|
|
| WATTS |
| 100 | 145 | 195 |
| 240 |
|
| 290 |
| ||||
|
|
|
|
|
|
|
|
| CFM |
| 971 | 997 | 1006 |
| 1022 |
|
| 1029 |
| |||
| HEATING | MEDIUM LOW |
| OFF |
| ON | TEMP. RISE |
| 58 | 56 | 56 |
| 55 |
|
| 54 |
| |||||
|
|
|
|
|
|
| WATTS |
| 115 | 170 | 220 |
| 280 |
|
| 335 |
| |||||
| 1ST |
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
| CFM |
| 1136 | 1146 | 1165 |
| 1180 |
|
| 1184 |
| ||||
| STAGE |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| MEDIUM ** |
| ON |
| OFF | TEMP. RISE |
| 49 | 49 | 48 |
| 47 |
|
| 47 |
| ||||||
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
| WATTS |
| 160 | 230 | 295 |
| 365 |
|
| 425 |
| ||||
|
|
|
|
|
|
|
|
| CFM |
| 1258 | 1298 | 1319 |
| 1328 |
|
| 1286 |
| |||
|
| HIGH |
| OFF |
| OFF | TEMP. RISE |
| 44 | 43 | 42 |
| 42 |
|
| 44 |
| |||||
|
|
|
|
|
|
|
| WATTS |
| 225 | 300 | 390 |
| 450 |
|
| 490 |
| ||||
|
|
|
|
|
|
|
|
| CFM |
| 1260 | 1304 | 1329 |
| 1334 |
|
| 1317 |
| |||
|
| LOW |
| ON |
| ON | TEMP. RISE |
| 68 | 66 | 65 |
| 65 |
|
| 65 |
| |||||
|
|
|
|
|
|
|
| WATTS |
| 213 | 305 | 380 |
| 460 |
|
| 510 |
| ||||
|
|
|
|
|
|
|
|
| CFM |
| 1464 | 1471 | 1478 |
| 1478 |
|
| 1350 |
| |||
| HEATING | MEDIUM LOW |
| OFF |
| ON | TEMP. RISE |
| 59 | 59 | 58 |
| 58 |
|
| 64 |
| |||||
|
|
|
|
|
|
| WATTS |
| 315 | 405 | 485 |
| 560 |
|
| 540 |
| |||||
| 2ND |
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
| CFM |
| 1631 | 1678 | 1690 |
| 1579 |
|
| 1419 |
| ||||
| STAGE |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| MEDIUM ** |
| ON |
| OFF | TEMP. RISE |
| 53 | 51 | 51 |
| 55 |
|
| 61 |
| ||||||
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
| WATTS |
| 450 | 570 | 670 |
| 645 |
|
| 585 |
| ||||
|
|
|
|
|
|
|
|
| CFM |
| 1846 | 1867 | 1794 |
| 1644 |
|
| 1498 |
| |||
|
| HIGH |
| OFF |
| OFF | TEMP. RISE |
| 47 | 46 | 48 |
| 52 |
|
| 57 |
| |||||
|
|
|
|
|
|
|
| WATTS |
| 640 | 760 | 770 |
| 700 |
|
| 650 |
| ||||
| NOTES: * First letter may be "A" or "T" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ** Factory setting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| *UH2C100A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER | |||||||||||||||||||||
| OUTDOOR | AIRFLOW |
|
| DIP SWITCH SETTING |
|
| EXTERNAL STATIC PRESSURE | ||||||||||||||
| UNIT SIZE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| SETTING |
|
|
|
|
|
|
|
|
|
|
| 0.1 | 0.3 | 0.5 |
| 0.7 | 0.9 |
| |||
| (TONS) |
| SW 1 |
| SW 2 |
| SW 3 |
| SW 4 |
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOW |
| ON |
| ON |
| OFF |
| ON | CFM |
| 808 | 824 | 840 |
| 835 | 830 |
| |||
|
| (350 CFM/TON) |
|
|
|
| WATTS |
| 75 | 125 | 170 |
| 210 | 250 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| 2.5 | NORMAL |
| ON |
| ON |
| OFF |
| OFF | CFM |
| 938 | 963 | 959 |
| 964 | 975 |
| |||
| (400 CFM/TON) |
|
|
|
| WATTS |
| 100 | 160 | 205 |
| 255 | 310 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
| HIGH |
| ON |
| ON |
| ON |
| OFF | CFM |
| 1058 | 1100 | 1121 |
| 1136 | 1142 |
| |||
|
| (450 CFM/TON) |
|
|
|
| WATTS |
| 150 | 200 | 265 |
| 330 | 395 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
| LOW |
| OFF |
| ON |
| OFF |
| ON | CFM |
| 1004 | 1010 | 1027 |
| 1044 | 1050 |
| |||
|
| (350 CFM/TON) |
|
|
|
| WATTS |
| 120 | 175 | 230 |
| 285 | 345 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| 3.0 | NORMAL |
| OFF |
| ON |
| OFF |
| OFF | CFM |
| 1141 | 1190 | 1214 |
| 1229 | 1234 |
| |||
| (400 CFM/TON) |
|
|
|
| WATTS |
| 170 | 245 | 310 |
| 380 | 450 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
| HIGH |
| OFF |
| ON |
| ON |
| OFF | CFM |
| 1336 | 1375 | 1387 |
| 1388 | 1384 |
| |||
|
| (450 CFM/TON) |
|
|
|
| WATTS |
| 250 | 330 | 410 |
| 480 | 545 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
| LOW |
| ON |
| OFF |
| OFF |
| ON | CFM |
| 1153 | 1206 | 1230 |
| 1239 | 1244 |
| |||
|
| (350 CFM/TON) |
|
|
|
| WATTS |
| 180 | 250 | 320 |
| 395 | 460 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| 3.5 | NORMAL |
| ON |
| OFF |
| OFF |
| OFF | CFM |
| 1390 | 1418 | 1439 |
| 1441 | 1373 |
| |||
| (400 CFM/TON) |
|
|
|
| WATTS |
| 285 | 465 | 445 |
| 515 | 540 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
| HIGH |
| ON |
| OFF |
| ON |
| OFF | CFM |
| 1575 | 1606 | 1632 |
| 1596 | 1445 |
| |||
|
| (450 CFM/TON) |
|
|
|
| WATTS |
| 400 | 495 | 590 |
| 645 | 590 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
| LOW |
| OFF |
| OFF |
| OFF |
| ON | CFM |
| 1388 | 1423 | 1444 |
| 1444 | 1390 |
| |||
|
| (350 CFM/TON) |
|
|
|
| WATTS |
| 290 | 360 | 440 |
| 515 | 540 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| 4.0 | NORMAL |
| OFF |
| OFF |
| OFF |
| OFF | CFM |
| 1610 | 1641 | 1666 |
| 1607 | 1449 |
| |||
| (400 CFM/TON) |
|
|
|
| WATTS |
| 415 | 515 | 635 |
| 650 | 595 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
| HIGH |
| OFF |
| OFF |
| ON |
| OFF | CFM |
| 1847 | 1863 | 1816 |
| 1687 | 1532 |
| |||
|
| (450 CFM/TON) |
|
|
|
| WATTS |
| 630 | 735 | 780 |
| 720 | 665 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES: *First letter may be "A" or "T"
1.At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
12
Pub. No.