Manual background

*UH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

 

 

 

 

 

 

 

1st Stage Capacity =

50,440

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2nd Stage Capacity =

77,600

 

 

 

 

 

 

 

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

 

SW 7

 

SW 8

 

 

 

 

0.1

0.3

0.5

 

0.7

 

 

0.9

 

 

 

 

 

 

 

 

CFM

 

 

800

800

800

 

800

 

 

800

 

LOW

 

ON

 

ON

TEMP. RISE

 

56

56

56

 

56

 

 

56

 

 

 

 

 

 

 

 

WATTS

 

105

140

180

 

220

 

 

265

 

 

 

 

 

 

 

 

CFM

 

 

860

880

890

 

920

 

 

910

HEATING

MEDIUM LOW

 

OFF

 

ON

TEMP. RISE

 

52

51

50

 

48

 

 

49

 

 

 

 

 

 

 

WATTS

 

115

165

215

 

265

 

 

320

1ST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

960

990

1000

 

1020

 

 

1010

STAGE

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL **

 

ON

 

OFF

TEMP. RISE

 

46

45

44

 

44

 

 

44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATTS

 

150

200

230

 

310

 

 

350

 

 

 

 

 

 

 

 

CFM

 

 

1080

1110

1120

 

1120

 

 

1080

 

HIGH

 

OFF

 

OFF

TEMP. RISE

 

41

40

40

 

40

 

 

41

 

 

 

 

 

 

 

 

WATTS

 

195

255

315

 

365

 

 

390

 

 

 

 

 

 

 

 

CFM

 

 

1100

1100

1120

 

1120

 

 

1090

HEATING

LOW

 

ON

 

ON

TEMP. RISE

 

62

62

61

 

61

 

 

63

 

 

 

 

 

 

 

WATTS

 

205

260

320

 

370

 

 

400

2ND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

1210

1240

1260

 

1260

 

 

1130

STAGE

MEDIUM LOW

 

OFF

 

ON

 

 

 

 

 

 

 

 

TEMP. RISE

 

57

55

54

 

54

 

 

61

 

 

 

 

 

 

 

 

WATTS

 

265

340

410

 

470

 

 

430

 

 

 

 

 

 

 

 

CFM

 

 

1360

1390

1400

 

1360

 

 

1210

 

NORMAL **

 

ON

 

OFF

TEMP. RISE

 

50

49

49

 

50

 

 

57

 

 

 

 

 

 

 

 

WATTS

 

365

445

500

 

535

 

 

475

 

 

 

 

 

 

 

 

CFM

 

 

1360

1390

1400

 

1350

 

 

1180

 

HIGH

 

OFF

 

OFF

TEMP. RISE

 

50

49

49

 

51

 

 

58

 

 

 

 

 

 

 

 

WATTS

 

355

450

520

 

535

 

 

465

NOTES: * First letter may be "A" or "T"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** Factory setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*UH2B080A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

UNIT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING

 

SW 1

 

SW 2

 

SW 3

 

SW 4

 

 

0.1

 

0.3

0.5

 

0.7

 

0.9

(TONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

ON

 

ON

 

OFF

 

ON

CFM

 

857

 

849

841

 

833

825

 

(350 CFM/TON)

 

 

 

 

WATTS

 

107

 

143

179

 

223

266

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

NORMAL

 

ON

 

ON

 

OFF

 

OFF

CFM

 

970

 

971

973

 

966

960

(400 CFM/TON)

 

 

 

 

WATTS

 

158

 

205

251

 

298

345

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

ON

 

ON

 

ON

 

OFF

CFM

 

1082

 

1093

1104

 

1099

1095

 

(450 CFM/TON)

 

 

 

 

WATTS

 

209

 

266

323

 

374

424

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

OFF

 

ON

 

OFF

 

ON

CFM

 

1004

 

1019

1035

 

1038

1041

 

(350 CFM/TON)

 

 

 

 

WATTS

 

153

 

210

267

 

321

374

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0

NORMAL

 

OFF

 

ON

 

OFF

 

OFF

CFM

 

1163

 

1173

1184

 

1179

1174

(400 CFM/TON)

 

 

 

 

WATTS

 

249

 

311

372

 

426

480

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

OFF

 

ON

 

ON

 

OFF

CFM

 

1323

 

1328

1332

 

1320

1307

 

(450 CFM/TON)

 

 

 

 

WATTS

 

345

 

411

477

 

532

586

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

ON

 

OFF

 

OFF

 

ON

CFM

 

1176

 

1188

1200

 

1195

1190

 

(350 CFM/TON)

 

 

 

 

WATTS

 

254

 

317

380

 

437

494

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5

NORMAL

 

ON

 

OFF

 

OFF

 

OFF

CFM

 

1356

 

1362

1368

 

1353

1339

(400 CFM/TON)

 

 

 

 

WATTS

 

379

 

446

514

 

568

623

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

ON

 

OFF

 

ON

 

OFF

CFM

 

1536

 

1536

1536

 

1512

1488

 

(450 CFM/TON)

 

 

 

 

WATTS

 

503

 

575

647

 

699

751

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

OFF

 

OFF

 

OFF

 

ON

CFM

 

1376

 

1367

1359

 

1354

1348

 

(350 CFM/TON)

 

 

 

 

WATTS

 

374

 

429

483

 

547

611

 

 

 

 

 

 

 

 

 

 

 

 

 

4.0

NORMAL

 

OFF

 

OFF

 

OFF

 

OFF

CFM

 

1562

 

1562

1563

 

1531

1499

(400 CFM/TON)

 

 

 

 

WATTS

 

530

 

604

677

 

720

765

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

OFF

 

OFF

 

ON

 

OFF

CFM

 

1768

 

1759

1749

 

1654

1559

 

(450 CFM/TON)

 

 

 

 

WATTS

 

757

 

830

902

 

866

829

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES: * First letter may be "A" or "T"

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.