*UH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
|
|
|
|
|
|
|
|
|
|
|
| 1st Stage Capacity = | 50,440 |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| 2nd Stage Capacity = | 77,600 |
|
|
|
|
|
| |||
| AIRFLOW |
| DIP SWITCH SETTING |
|
|
|
|
|
| EXTERNAL STATIC PRESSURE |
| |||||||||||
| SETTING |
| SW 7 |
| SW 8 |
|
|
|
| 0.1 | 0.3 | 0.5 |
| 0.7 |
|
| 0.9 | |||||
|
|
|
|
|
|
|
| CFM |
|
| 800 | 800 | 800 |
| 800 |
|
| 800 | ||||
| LOW |
| ON |
| ON | TEMP. RISE |
| 56 | 56 | 56 |
| 56 |
|
| 56 | |||||||
|
|
|
|
|
|
|
| WATTS |
| 105 | 140 | 180 |
| 220 |
|
| 265 | |||||
|
|
|
|
|
|
|
| CFM |
|
| 860 | 880 | 890 |
| 920 |
|
| 910 | ||||
HEATING | MEDIUM LOW |
| OFF |
| ON | TEMP. RISE |
| 52 | 51 | 50 |
| 48 |
|
| 49 | |||||||
|
|
|
|
|
|
| WATTS |
| 115 | 165 | 215 |
| 265 |
|
| 320 | ||||||
1ST |
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
| CFM |
|
| 960 | 990 | 1000 |
| 1020 |
|
| 1010 | |||||
STAGE |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
NORMAL ** |
| ON |
| OFF | TEMP. RISE |
| 46 | 45 | 44 |
| 44 |
|
| 44 | ||||||||
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
| WATTS |
| 150 | 200 | 230 |
| 310 |
|
| 350 | |||||
|
|
|
|
|
|
|
| CFM |
|
| 1080 | 1110 | 1120 |
| 1120 |
|
| 1080 | ||||
| HIGH |
| OFF |
| OFF | TEMP. RISE |
| 41 | 40 | 40 |
| 40 |
|
| 41 | |||||||
|
|
|
|
|
|
|
| WATTS |
| 195 | 255 | 315 |
| 365 |
|
| 390 | |||||
|
|
|
|
|
|
|
| CFM |
|
| 1100 | 1100 | 1120 |
| 1120 |
|
| 1090 | ||||
HEATING | LOW |
| ON |
| ON | TEMP. RISE |
| 62 | 62 | 61 |
| 61 |
|
| 63 | |||||||
|
|
|
|
|
|
| WATTS |
| 205 | 260 | 320 |
| 370 |
|
| 400 | ||||||
2ND |
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
| CFM |
|
| 1210 | 1240 | 1260 |
| 1260 |
|
| 1130 | |||||
STAGE | MEDIUM LOW |
| OFF |
| ON |
|
|
|
|
| ||||||||||||
|
|
| TEMP. RISE |
| 57 | 55 | 54 |
| 54 |
|
| 61 | ||||||||||
|
|
|
|
|
|
|
| WATTS |
| 265 | 340 | 410 |
| 470 |
|
| 430 | |||||
|
|
|
|
|
|
|
| CFM |
|
| 1360 | 1390 | 1400 |
| 1360 |
|
| 1210 | ||||
| NORMAL ** |
| ON |
| OFF | TEMP. RISE |
| 50 | 49 | 49 |
| 50 |
|
| 57 | |||||||
|
|
|
|
|
|
|
| WATTS |
| 365 | 445 | 500 |
| 535 |
|
| 475 | |||||
|
|
|
|
|
|
|
| CFM |
|
| 1360 | 1390 | 1400 |
| 1350 |
|
| 1180 | ||||
| HIGH |
| OFF |
| OFF | TEMP. RISE |
| 50 | 49 | 49 |
| 51 |
|
| 58 | |||||||
|
|
|
|
|
|
|
| WATTS |
| 355 | 450 | 520 |
| 535 |
|
| 465 | |||||
NOTES: * First letter may be "A" or "T" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
** Factory setting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
*UH2B080A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER | ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
OUTDOOR | AIRFLOW |
| DIP SWITCH SETTING |
|
| EXTERNAL STATIC PRESSURE | ||||||||||||||||
UNIT SIZE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SETTING |
| SW 1 |
| SW 2 |
| SW 3 |
| SW 4 |
|
| 0.1 |
| 0.3 | 0.5 |
| 0.7 |
| 0.9 | ||||
(TONS) |
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| LOW |
| ON |
| ON |
| OFF |
| ON | CFM |
| 857 |
| 849 | 841 |
| 833 | 825 | ||||
| (350 CFM/TON) |
|
|
|
| WATTS |
| 107 |
| 143 | 179 |
| 223 | 266 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
2.5 | NORMAL |
| ON |
| ON |
| OFF |
| OFF | CFM |
| 970 |
| 971 | 973 |
| 966 | 960 | ||||
(400 CFM/TON) |
|
|
|
| WATTS |
| 158 |
| 205 | 251 |
| 298 | 345 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| HIGH |
| ON |
| ON |
| ON |
| OFF | CFM |
| 1082 |
| 1093 | 1104 |
| 1099 | 1095 | ||||
| (450 CFM/TON) |
|
|
|
| WATTS |
| 209 |
| 266 | 323 |
| 374 | 424 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| LOW |
| OFF |
| ON |
| OFF |
| ON | CFM |
| 1004 |
| 1019 | 1035 |
| 1038 | 1041 | ||||
| (350 CFM/TON) |
|
|
|
| WATTS |
| 153 |
| 210 | 267 |
| 321 | 374 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
3.0 | NORMAL |
| OFF |
| ON |
| OFF |
| OFF | CFM |
| 1163 |
| 1173 | 1184 |
| 1179 | 1174 | ||||
(400 CFM/TON) |
|
|
|
| WATTS |
| 249 |
| 311 | 372 |
| 426 | 480 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| HIGH |
| OFF |
| ON |
| ON |
| OFF | CFM |
| 1323 |
| 1328 | 1332 |
| 1320 | 1307 | ||||
| (450 CFM/TON) |
|
|
|
| WATTS |
| 345 |
| 411 | 477 |
| 532 | 586 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| LOW |
| ON |
| OFF |
| OFF |
| ON | CFM |
| 1176 |
| 1188 | 1200 |
| 1195 | 1190 | ||||
| (350 CFM/TON) |
|
|
|
| WATTS |
| 254 |
| 317 | 380 |
| 437 | 494 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
3.5 | NORMAL |
| ON |
| OFF |
| OFF |
| OFF | CFM |
| 1356 |
| 1362 | 1368 |
| 1353 | 1339 | ||||
(400 CFM/TON) |
|
|
|
| WATTS |
| 379 |
| 446 | 514 |
| 568 | 623 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| HIGH |
| ON |
| OFF |
| ON |
| OFF | CFM |
| 1536 |
| 1536 | 1536 |
| 1512 | 1488 | ||||
| (450 CFM/TON) |
|
|
|
| WATTS |
| 503 |
| 575 | 647 |
| 699 | 751 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| LOW |
| OFF |
| OFF |
| OFF |
| ON | CFM |
| 1376 |
| 1367 | 1359 |
| 1354 | 1348 | ||||
| (350 CFM/TON) |
|
|
|
| WATTS |
| 374 |
| 429 | 483 |
| 547 | 611 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
4.0 | NORMAL |
| OFF |
| OFF |
| OFF |
| OFF | CFM |
| 1562 |
| 1562 | 1563 |
| 1531 | 1499 | ||||
(400 CFM/TON) |
|
|
|
| WATTS |
| 530 |
| 604 | 677 |
| 720 | 765 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| HIGH |
| OFF |
| OFF |
| ON |
| OFF | CFM |
| 1768 |
| 1759 | 1749 |
| 1654 | 1559 | ||||
| (450 CFM/TON) |
|
|
|
| WATTS |
| 757 |
| 830 | 902 |
| 866 | 829 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES: * First letter may be "A" or "T"
1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
11