*DH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
|
|
|
|
| 1st STAGE CAPACITY = 37,440 |
|
| |||
|
|
|
|
| 2nd STAGE CAPACITY = 57,600 |
|
| |||
| AIRFLOW | DIP SWITCH SETTING |
|
| EXTERNAL STATIC PRESSURE |
| ||||
| SETTING | SW 7 | SW 8 |
| 0.1 | 0.3 | 0.5 | 0.7 | 0.9 | |
|
|
|
| CFM | 600 | 600 | 600 | 600 | 600 | |
| LOW | ON | ON | TEMP. RISE | 56 | 56 | 56 | 56 | 56 | |
|
|
|
| WATTS | 55 | 85 | 120 | 150 | 185 | |
|
|
|
| CFM | 675 | 675 | 675 | 675 | 675 | |
HEATING | MEDIUM LOW | OFF | ON | TEMP. RISE | 50 | 50 | 50 | 50 | 50 | |
|
|
| WATTS | 65 | 105 | 140 | 175 | 205 | ||
1ST |
|
|
| |||||||
|
|
| CFM | 750 | 750 | 750 | 750 | 750 | ||
STAGE |
|
|
| |||||||
NORMAL ** | ON | OFF | TEMP. RISE | 45 | 45 | 45 | 45 | 45 | ||
| ||||||||||
|
|
|
| WATTS | 85 | 125 | 160 | 210 | 260 | |
|
|
|
| CFM | 850 | 850 | 850 | 850 | 850 | |
| HIGH | OFF | OFF | TEMP. RISE | 40 | 40 | 40 | 40 | 40 | |
|
|
|
| WATTS | 115 | 155 | 205 | 260 | 320 | |
|
|
|
| CFM | 900 | 900 | 900 | 900 | 900 | |
| LOW | ON | ON | TEMP. RISE | 58 | 58 | 58 | 58 | 58 | |
|
|
|
| WATTS | 125 | 165 | 220 | 270 | 315 | |
|
|
|
| CFM | 1000 | 1050 | 1050 | 1050 | 1050 | |
HEATING | MEDIUM LOW | OFF | ON | TEMP. RISE | 52 | 50 | 50 | 50 | 50 | |
|
|
| WATTS | 170 | 230 | 295 | 335 | 370 | ||
2ND |
|
|
| |||||||
|
|
| CFM | 1100 | 1150 | 1150 | 1150 | 1100 | ||
STAGE |
|
|
| |||||||
NORMAL ** | ON | OFF | TEMP. RISE | 47 | 45 | 45 | 45 | 47 | ||
| ||||||||||
|
|
|
| WATTS | 215 | 285 | 340 | 395 | 440 | |
|
|
|
| CFM | 1300 | 1325 | 1325 | 1250 | 1200 | |
| HIGH | OFF | OFF | TEMP. RISE | 40 | 39 | 39 | 42 | 43 | |
|
|
|
| WATTS | 330 | 385 | 455 | 465 | 470 |
NOTES:
*First letter may be "A" or "T" ** Factory setting
*DH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR | AIRFLOW |
| DIP SWITCH SETTING |
|
|
| EXTERNAL STATIC PRESSURE |
| |||||||
UNIT SIZE |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
SETTING | SW 1 |
| SW 2 | SW 3 |
| SW 4 |
| 0.1 |
| 0.3 | 0.5 | 0.7 |
| 0.9 | |
(TONS) |
|
|
|
|
| ||||||||||
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOW | OFF |
| OFF | OFF |
| ON | CFM | 525 |
| 525 | 525 | 525 |
| 525 |
| (350 CFM/TON) |
|
| WATTS | 45 |
| 70 | 100 | 135 |
| 160 | ||||
|
|
|
|
|
|
|
|
| |||||||
1.5 | NORMAL | OFF |
| OFF | OFF |
| OFF | CFM | 600 |
| 600 | 600 | 600 |
| 600 |
(400 CFM/TON) |
|
| WATTS | 55 |
| 85 | 120 | 150 |
| 185 | |||||
|
|
|
|
|
|
|
|
| |||||||
| HIGH | OFF |
| OFF | ON |
| OFF | CFM | 675 |
| 675 | 625 | 675 |
| 675 |
| (450 CFM/TON) |
|
| WATTS | 65 |
| 105 | 140 | 175 |
| 205 | ||||
|
|
|
|
|
|
|
|
| |||||||
| LOW | ON |
| ON | OFF |
| ON | CFM | 700 |
| 700 | 700 | 700 |
| 700 |
| (350 CFM/TON) |
|
| WATTS | 70 |
| 115 | 145 | 185 |
| 220 | ||||
|
|
|
|
|
|
|
|
| |||||||
2.0 | NORMAL | ON |
| ON | OFF |
| OFF | CFM | 800 |
| 800 | 800 | 800 |
| 800 |
(400 CFM/TON) |
|
| WATTS | 100 |
| 135 | 175 | 225 |
| 280 | |||||
|
|
|
|
|
|
|
|
| |||||||
| HIGH | ON |
| ON | ON |
| OFF | CFM | 900 |
| 900 | 900 | 900 |
| 900 |
| (450 CFM/TON) |
|
| WATTS | 125 |
| 165 | 220 | 270 |
| 330 | ||||
|
|
|
|
|
|
|
|
| |||||||
| LOW | OFF |
| ON | OFF |
| ON | CFM | 875 |
| 875 | 875 | 875 |
| 875 |
| (350 CFM/TON) |
|
| WATTS | 115 |
| 160 | 210 | 260 |
| 310 | ||||
|
|
|
|
|
|
|
|
| |||||||
2.5 | NORMAL | OFF |
| ON | OFF |
| OFF | CFM | 1000 |
| 1000 | 1000 | 1000 |
| 1000 |
(400 CFM/TON) |
|
| WATTS | 150 |
| 207 | 265 | 320 |
| 380 | |||||
|
|
|
|
|
|
|
|
| |||||||
| HIGH | OFF |
| ON | ON |
| OFF | CFM | 1125 |
| 1125 | 1125 | 1125 |
| 1125 |
| (450 CFM/TON) |
|
| WATTS | 215 |
| 285 | 340 | 395 |
| 440 | ||||
|
|
|
|
|
|
|
|
| |||||||
| LOW | ON |
| OFF | OFF |
| ON | CFM | 1050 |
| 1050 | 1050 | 1050 |
| 1050 |
| (350 CFM/TON) |
|
| WATTS | 175 |
| 240 | 305 | 345 |
| 380 | ||||
|
|
|
|
|
|
|
|
| |||||||
3 | NORMAL | ON |
| OFF | OFF |
| OFF | CFM | 1200 |
| 1200 | 1200 | 1200 |
| 1100 |
(400 CFM/TON) |
|
| WATTS | 240 |
| 315 | 385 | 440 |
| 410 | |||||
|
|
|
|
|
|
|
|
| |||||||
| HIGH | ON |
| OFF | ON |
| OFF | CFM | 1350 |
| 1350 | 1350 | 1275 |
| 1170 |
| (450 CFM/TON) |
|
| WATTS | 330 |
| 410 | 500 | 485 |
| 450 | ||||
|
|
|
|
|
|
|
|
|
NOTES: * First letter may be "A" or "T"
1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.