*DH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

1st STAGE CAPACITY =

49,400

 

 

 

 

 

 

 

2nd STAGE CAPACITY = 76,000

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

CFM

800

800

800

790

 

 

LOW

ON

ON

TEMP. RISE

56

56

56

56

-

 

 

 

 

WATTS

130

170

210

245

 

 

 

 

 

CFM

900

900

900

900

 

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

49

49

49

49

-

 

 

 

WATTS

162

210

260

295

 

1ST

 

 

 

 

 

 

 

CFM

1000

1000

1000

1000

800

STAGE

 

 

 

MEDIUM **

ON

OFF

TEMP. RISE

44

44

44

44

56

 

 

 

 

 

WATTS

205

265

310

345

295

 

 

 

 

CFM

1170

1170

1170

1020

830

 

HIGH

OFF

OFF

TEMP. RISE

38

38

38

44

54

 

 

 

 

WATTS

305

350

400

360

310

 

 

 

 

CFM

1150

1150

1150

1020

830

 

LOW

ON

ON

TEMP. RISE

60

60

60

67***

83***

 

 

 

 

WATTS

285

345

385

360

305

 

 

 

 

CFM

1275

1275

1200

1040

900

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

54

54

57

66***

76***

 

 

 

WATTS

380

445

425

380

350

2ND

 

 

 

 

 

 

CFM

1430

1340

1220

1090

930

STAGE

 

 

 

MEDIUM **

ON

OFF

TEMP. RISE

48

51

56

63

74***

 

 

 

 

 

WATTS

515

490

455

410

380

 

 

 

 

CFM

1430

1340

1220

1090

930

 

HIGH

OFF

OFF

TEMP. RISE

48

51

56

63

74***

 

 

 

 

WATTS

515

490

455

410

380

NOTES: * - First letter may be "A" or "T"

**Factory setting

***Above MAX Temperature change value

*DH2B080A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING

SW 1

 

SW 2

SW 3

 

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

(TONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

ON

OFF

 

ON

CFM

849

 

865

881

878

 

876

 

(350 CFM/TON)

 

 

WATTS

141

 

191

241

294

 

348

 

 

 

 

 

 

 

 

 

2.5

NORMAL

ON

 

ON

OFF

 

OFF

CFM

953

 

965

977

973

 

970

(400 CFM/TON)

 

 

WATTS

195

 

250

305

358

 

411

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

ON

ON

 

OFF

CFM

1057

 

1065

1073

1069

 

1064

 

(450 CFM/TON)

 

 

WATTS

249

 

309

369

422

 

474

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

 

ON

CFM

999

 

1003

1008

1018

 

1029

 

(350 CFM/TON)

 

 

WATTS

188

 

241

394

354

 

414

 

 

 

 

 

 

 

 

 

3.0

NORMAL

OFF

 

ON

OFF

 

OFF

CFM

1144

 

1150

1156

1160

 

1165

(400 CFM/TON)

 

 

WATTS

300

 

362

423

486

 

548

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

 

OFF

CFM

1288

 

1297

1305

1303

 

1300

 

(450 CFM/TON)

 

 

WATTS

412

 

482

552

617

 

682

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

 

ON

CFM

1156

 

1165

1174

1177

 

1179

 

(350 CFM/TON)

 

 

WATTS

307

 

374

440

502

 

563

 

 

 

 

 

 

 

 

 

3.5

NORMAL

ON

 

OFF

OFF

 

OFF

CFM

1327

 

1335

1343

1325

 

1307

(400 CFM/TON)

 

 

WATTS

446

 

518

589

641

 

693

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

 

OFF

CFM

1506

 

1502

1498

1418

 

1338

 

(450 CFM/TON)

 

 

WATTS

634

 

703

771

746

 

721

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

OFF

OFF

 

ON

CFM

1327

 

1335

1343

1325

 

1307

 

(350 CFM/TON)

 

 

WATTS

446

 

518

589

641

 

693

 

 

 

 

 

 

 

 

 

4.0

NORMAL

OFF

 

OFF

OFF

 

OFF

CFM

1525

 

1522

1518

1430

 

1341

 

(400 CFM/TON)

 

 

WATTS

656

 

727

797

761

 

725

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

OFF

ON

 

OFF

CFM

1706

 

1635

1563

1471

 

1379

 

(450 CFM/TON)

 

 

WATTS

906

 

881

857

813

 

769

 

 

 

 

 

 

 

 

 

NOTES: * First letter may be "A" or "T"

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

17

Pub. No. 22-1814-08

Page 17
Image 17
Trane TDH2B080A9V3VA, TUH2C100A9V5VA, TUH2C100A9V4VA, TUH2B080A9V3VA 1st Stage Capacity = 49,400 2nd Stage Capacity = 76,000

TDH2B060A9V3VA, TDH2B080A9V4VA, TDH2B080A9V3VA, TDH2D120A9V5VA, TDH2C100A9V4VA specifications

Trane is renowned for its commitment to energy efficiency, innovation, and reliability, exemplified in its range of TUH2 series air handlers. Among these models, the TUH2C100A9V5VA, TUH2C100A9V4VA, TUH2D120A9V5VA, TUH2B080A9V3VA, and TUH2B080A9V4VA stand out with their advanced features and technologies designed to enhance indoor comfort and operational efficiency.

The TUH2C100A9V5VA and TUH2C100A9V4VA are both equipped for versatile applications, making them suitable for residential and light commercial purposes. These models feature a durable construction that ensures longevity even in demanding environments. Their design incorporates a high-efficiency blower that allows for optimized airflow, ensuring a balanced temperature throughout the space.

The TUH2D120A9V5VA model is tailored specifically for larger applications, providing enhanced performance and increased capacity. Its dual-stage heating function guarantees consistent warmth during colder months, while the integrated energy recovery ventilator contributes to improved indoor air quality by allowing for better ventilation. This model is particularly beneficial in increasingly energy-conscious markets, demonstrating Trane's commitment to sustainability.

Both the TUH2B080A9V3VA and TUH2B080A9V4VA are designed for maximum efficiency in smaller applications. They utilize variable speed technology, allowing them to adjust the airflow according to fluctuating demand. This efficient operation not only reduces energy consumption but also minimizes noise levels, creating a more comfortable and peaceful indoor environment.

All models in the TUH2 series feature advanced diagnostics and communication capabilities, enabling remote monitoring and management of the systems. This technology helps property owners track performance and energy usage in real-time, facilitating proactive maintenance and improving overall system reliability.

Trane's TUH2 series is built with a focus on quality and innovation, utilizing high-grade materials to withstand various environmental factors. Each unit is engineered for easy installation and maintenance, ensuring that technicians can efficiently service these robust systems. In summary, the TUH2 series air handlers provide a blend of performance, efficiency, and user-friendly features, making them an excellent choice for any indoor climate control needs.