Trane TDH2B080A9V4VA, TUH2C100A9V5VA, TUH2C100A9V4VA, TUH2B080A9V3VA manual 1st STAGE CAPACITY =

Models: TDH2B060A9V3VA TDH2B080A9V4VA TDH2B080A9V3VA TDH2D120A9V5VA TDH2C100A9V4VA TUH2B080A9V4VA TUH2D120A9V5VA TUH2B080A9V3VA TUH2C100A9V4VA TUH2C100A9V5VA

1 30
Download 30 pages 53.97 Kb
Page 18
Image 18
Manual background

*DH2C100A9V4V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

1st STAGE CAPACITY =

62,400

 

 

 

 

 

 

 

2nd STAGE CAPACITY = 96,000

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

CFM

923

955

960

958

947

 

LOW

ON

ON

TEMP. RISE

61

59

58

58

59

 

 

 

 

WATTS

110

165

210

265

310

 

 

 

 

CFM

1020

1047

1053

1042

1029

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

55

53

53

54

54

 

 

 

WATTS

145

190

250

295

350

1ST

 

 

 

 

 

 

CFM

1156

1166

1172

1177

1178

STAGE

 

 

 

MEDIUM **

ON

OFF

TEMP. RISE

48

48

48

48

48

 

 

 

 

 

WATTS

185

240

300

350

420

 

 

 

 

CFM

1275

1305

1328

1328

1328

 

HIGH

OFF

OFF

TEMP. RISE

44

43

42

42

42

 

 

 

 

WATTS

225

290

365

445

510

 

 

 

 

CFM

1298

1320

1335

1343

1343

 

LOW

ON

ON

TEMP. RISE

66

65

65

64

64

 

 

 

 

WATTS

235

305

380

445

520

 

 

 

 

CFM

1439

1459

1482

1483

1470

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

60

59

58

58

59

 

 

 

WATTS

310

390

470

550

610

2ND

 

 

 

 

 

 

CFM

1639

1650

1650

1644

1496

STAGE

 

 

 

MEDIUM **

ON

OFF

TEMP. RISE

53

52

52

52

58

 

 

 

 

 

WATTS

430

525

600

680

640

 

 

 

 

CFM

1790

1818

1813

1708

1535

 

HIGH

OFF

OFF

TEMP. RISE

18

47

47

50

56

 

 

 

 

WATTS

570

670

770

750

675

NOTES: * - First letter may be "A" or "T"

**Factory setting

***Above MAX temperature change

*DH2C100A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TONS)

SETTING

SW 1

 

SW 2

SW 3

 

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

ON

OFF

 

ON

CFM

870

 

885

887

881

 

876

 

(350 CFM/TON)

 

 

WATTS

100

 

140

185

230

 

270

 

 

 

 

 

 

 

 

 

2.5

NORMAL

ON

 

ON

OFF

 

OFF

CFM

989

 

1018

1016

1012

 

999

(400 CFM/TON)

 

 

WATTS

120

 

180

230

285

 

325

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

ON

ON

 

OFF

CFM

1124

 

1139

1130

1135

 

1135

 

(450 CFM/TON)

 

 

WATTS

175

 

225

275

335

 

390

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

 

ON

CFM

1053

 

1075

1070

1070

 

1049

 

(350 CFM/TON)

 

 

WATTS

145

 

200

245

295

 

350

 

 

 

 

 

 

 

 

 

3.0

NORMAL

OFF

 

ON

OFF

 

OFF

CFM

1186

 

1205

1220

1220

 

1216

(400 CFM/TON)

 

 

WATTS

195

 

255

310

370

 

440

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

 

OFF

CFM

1336

 

1366

1383

1385

 

1381

 

(450 CFM/TON)

 

 

WATTS

255

 

340

405

470

 

545

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

 

ON

CFM

1216

 

1225

1235

1240

 

1243

 

(350 CFM/TON)

 

 

WATTS

190

 

255

320

385

 

445

 

 

 

 

 

 

 

 

 

3.5

NORMAL

ON

 

OFF

OFF

 

OFF

CFM

1394

 

1422

1436

1437

 

1430

(400 CFM/TON)

 

 

WATTS

270

 

360

430

505

 

580

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

 

OFF

CFM

1579

 

1604

1610

1599

 

1517

 

(450 CFM/TON)

 

 

WATTS

395

 

475

555

645

 

640

 

 

 

 

 

 

 

 

 

4.0

LOW

OFF

 

OFF

OFF

 

ON

CFM

1377

 

1412

1426

1433

 

1428

(350 CFM/TON)

 

 

WATTS

270

 

355

430

510

 

575

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL

OFF

 

OFF

OFF

 

OFF

CFM

1599

 

1624

1636

1618

 

1512

 

(400 CFM/TON)

 

 

WATTS

425

 

510

585

670

 

635

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

OFF

ON

 

OFF

CFM

1801

 

1818

1815

1694

 

1525

 

(450 CFM/TON)

 

 

WATTS

580

 

690

775

735

 

660

 

 

 

 

 

 

 

 

 

NOTES: * - First letter may be "A" or "T"

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;

NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

18

Pub. No. 22-1814-08

Page 18
Image 18
Trane TDH2B080A9V4VA, TUH2C100A9V5VA, TUH2C100A9V4VA, TUH2B080A9V3VA, TUH2D120A9V5VA, TUH2B080A9V4VA manual 1st STAGE CAPACITY =