*DH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
|
|
|
|
| 1st STAGE CAPACITY = | 49,920 |
|
| ||
|
|
|
|
| 2nd STAGE CAPACITY = 76,800 |
|
| |||
| AIRFLOW | DIP SWITCH SETTING |
|
| EXTERNAL STATIC PRESSURE |
| ||||
| SETTING | SW 7 | SW 8 |
| 0.1 | 0.3 | 0.5 | 0.7 | 0.9 | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| CFM | 800 | 800 | 800 | 790 |
| |
| LOW | ON | ON | TEMP. RISE | 56 | 56 | 56 | 56 | - | |
|
|
|
| WATTS | 130 | 170 | 210 | 245 |
| |
|
|
|
| CFM | 900 | 900 | 900 | 900 |
| |
HEATING | MEDIUM LOW | OFF | ON | TEMP. RISE | 49 | 49 | 49 | 49 | - | |
|
|
| WATTS | 162 | 210 | 260 | 295 |
| ||
1ST |
|
|
|
| ||||||
|
|
| CFM | 1000 | 1000 | 1000 | 1000 | 800 | ||
STAGE |
|
|
| |||||||
NORMAL ** | ON | OFF | TEMP. RISE | 44 | 44 | 44 | 44 | 56 | ||
| ||||||||||
|
|
|
| WATTS | 205 | 265 | 310 | 345 | 295 | |
|
|
|
| CFM | 1170 | 1170 | 1170 | 1020 | 830 | |
| HIGH | OFF | OFF | TEMP. RISE | 38 | 38 | 38 | 44 | 54 | |
|
|
|
| WATTS | 305 | 350 | 400 | 360 | 310 | |
|
|
|
| CFM | 1150 | 1150 | 1150 | 1020 | 830 | |
| LOW | ON | ON | TEMP. RISE | 60 | 60 | 60 | 67*** | 83*** | |
|
|
|
| WATTS | 285 | 345 | 385 | 360 | 305 | |
|
|
|
| CFM | 1275 | 1275 | 1200 | 1040 | 900 | |
HEATING | MEDIUM LOW | OFF | ON | TEMP. RISE | 54 | 54 | 57 | 66*** | 76*** | |
|
|
| WATTS | 380 | 445 | 425 | 380 | 350 | ||
2ND |
|
|
| |||||||
|
|
| CFM | 1430 | 1340 | 1220 | 1090 | 930 | ||
STAGE |
|
|
| |||||||
NORMAL ** | ON | OFF | TEMP. RISE | 48 | 51 | 56 | 63 | 74*** | ||
| ||||||||||
|
|
|
| WATTS | 515 | 490 | 455 | 410 | 380 | |
|
|
|
| CFM | 1430 | 1340 | 1220 | 1090 | 930 | |
| HIGH | OFF | OFF | TEMP. RISE | 48 | 51 | 56 | 63 | 74*** | |
|
|
|
| WATTS | 515 | 490 | 455 | 410 | 380 |
NOTES: * - First letter may be "A" or "T"
**Factory setting
***Above MAX Temperature change value
*DH2B080A9V3V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR | AIRFLOW |
| DIP SWITCH SETTING |
|
| EXTERNAL STATIC PRESSURE |
| |||||||
UNIT SIZE |
|
|
|
|
|
|
|
|
|
|
|
|
| |
SETTING | SW 1 | SW 2 | SW 3 | SW 4 |
| 0.1 |
| 0.3 | 0.5 | 0.7 |
| 0.9 | ||
(TONS) |
|
|
| |||||||||||
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOW | ON |
| ON | OFF | ON | CFM | 700 |
| 700 | 700 | 680 |
| 670 |
| (350 CFM/TON) |
| WATTS | 95 |
| 105 | 115 | 200 |
| 235 | ||||
|
|
|
|
|
|
|
| |||||||
2.0 | NORMAL | ON |
| ON | OFF | OFF | CFM | 800 |
| 800 | 800 | 790 |
| 740 |
(400 CFM/TON) |
| WATTS | 130 |
| 160 | 205 | 245 |
| 265 | |||||
|
|
|
|
|
|
|
| |||||||
| HIGH | ON |
| ON | ON | OFF | CFM | 900 |
| 900 | 900 | 900 |
| 750 |
| (450 CFM/TON) |
| WATTS | 160 |
| 215 | 255 | 300 |
| 270 | ||||
|
|
|
|
|
|
|
| |||||||
| LOW | OFF |
| ON | OFF | ON | CFM | 875 |
| 875 | 875 | 875 |
| 760 |
| (350 CFM/TON) |
| WATTS | 145 |
| 185 | 240 | 280 |
| 270 | ||||
|
|
|
|
|
|
|
| |||||||
2.5 | NORMAL | OFF |
| ON | OFF | OFF | CFM | 1000 |
| 1000 | 1000 | 1000 |
| 800 |
(400 CFM/TON) |
| WATTS | 205 |
| 265 | 310 | 340 |
| 295 | |||||
|
|
|
|
|
|
|
| |||||||
| HIGH | OFF |
| ON | ON | OFF | CFM | 1150 |
| 1150 | 1150 | 1020 |
| 800 |
| (450 CFM/TON) |
| WATTS | 295 |
| 340 | 385 | 350 |
| 300 | ||||
|
|
|
|
|
|
|
| |||||||
| LOW | ON |
| OFF | OFF | ON | CFM | 1050 |
| 1050 | 1050 | 1010 |
| 800 |
| (350 CFM/TON) |
| WATTS | 235 |
| 295 | 340 | 350 |
| 290 | ||||
|
|
|
|
|
|
|
| |||||||
3.0 | NORMAL | ON |
| OFF | OFF | OFF | CFM | 1200 |
| 1200 | 1200 | 1040 |
| 840 |
(400 CFM/TON) |
| WATTS | 335 |
| 385 | 410 | 365 |
| 310 | |||||
|
|
|
|
|
|
|
| |||||||
| HIGH | ON |
| OFF | ON | OFF | CFM | 1350 |
| 1350 | 1210 | 1070 |
| 900 |
| (450 CFM/TON) |
| WATTS | 455 |
| 480 | 435 | 390 |
| 345 | ||||
|
|
|
|
|
|
|
|
NOTES: * First letter may be "A" or "T"
1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
16
Pub. No.