*UH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
|
|
|
|
|
|
|
|
|
|
|
| 1st Stage Capacity = | 37,830 |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| 2nd Stage Capacity = | 58,200 |
|
|
|
|
|
|
| |||
| AIRFLOW | DIP SWITCH SETTING |
|
|
|
|
|
|
| EXTERNAL STATIC PRESSURE |
| ||||||||||||
| SETTING |
| SW 7 |
| SW 8 |
|
|
|
|
| 0.1 |
| 0.3 |
| 0.5 |
|
| 0.7 |
|
| 0.9 | ||
|
|
|
|
|
|
|
|
| CFM |
| 600 |
| 600 |
| 600 |
|
| 600 |
|
|
| ||
| LOW |
| ON |
| ON |
| TEMP. RISE |
| 57 |
| 57 |
| 57 |
|
| 57 |
|
| - | ||||
|
|
|
|
|
|
|
| WATTS |
| 85 |
| 110 |
| 155 |
|
| 190 |
|
|
| |||
|
|
|
|
|
|
|
|
| CFM |
| 700 |
| 700 |
| 700 |
|
| 700 |
|
|
| ||
HEATING | MEDIUM LOW |
| OFF |
| ON |
| TEMP. RISE |
| 49 |
| 49 |
| 49 |
|
| 49 |
|
| - | ||||
|
|
|
|
|
|
| WATTS |
| 90 |
| 130 |
| 175 |
|
| 210 |
|
|
| ||||
1ST |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| CFM |
| 775 |
| 775 |
| 775 |
|
| 775 |
|
|
| |||
STAGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
NORMAL ** |
| ON |
| OFF |
| TEMP. RISE |
| 44 |
| 44 |
| 44 |
|
| 44 |
|
| - | |||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
| WATTS |
| 105 |
| 155 |
| 195 |
|
| 240 |
|
|
| |||
|
|
|
|
|
|
|
|
| CFM |
| 870 |
| 870 |
| 870 |
|
| 870 |
|
|
| ||
| HIGH |
| OFF |
| OFF |
| TEMP. RISE |
| 39 |
| 39 |
| 39 |
|
| 39 |
|
| - | ||||
|
|
|
|
|
|
|
| WATTS |
| 135 |
| 185 |
| 235 |
|
| 290 |
|
|
| |||
|
|
|
|
|
|
|
|
| CFM |
| 860 |
| 920 |
| 920 |
|
| 920 |
|
| 670 | ||
| LOW |
| ON |
| ON |
| TEMP. RISE |
| 61 |
| 57 |
| 57 |
|
| 57 |
|
| 79 | ||||
|
|
|
|
|
|
|
| WATTS |
| 140 |
| 200 |
| 245 |
|
| 300 |
|
| 245 | |||
|
|
|
|
|
|
|
|
| CFM |
| 1000 |
| 1000 |
| 1000 |
|
| 1000 |
| 700 | |||
HEATING | MEDIUM LOW |
| OFF |
| ON |
| TEMP. RISE |
| 53 |
| 53 |
| 53 |
|
| 53 |
|
| 75 | ||||
|
|
|
|
|
|
| WATTS |
| 190 |
| 255 |
| 305 |
|
| 340 |
|
| 255 | ||||
2ND |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
| CFM |
| 1125 |
| 1125 |
| 1125 |
|
| 1025 |
| 775 | ||||
STAGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
NORMAL ** |
| ON |
| OFF |
| TEMP. RISE |
| 47 |
| 47 |
| 47 |
|
| 51 |
|
| 68 | |||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
| WATTS |
| 250 |
| 315 |
| 370 |
|
| 355 |
|
| 285 | |||
|
|
|
|
|
|
|
|
| CFM |
| 1250 |
| 1250 |
| 1250 |
|
| 1100 |
| 1000 | |||
| HIGH |
| OFF |
| OFF |
| TEMP. RISE |
| 42 |
| 42 |
| 42 |
|
| 48 |
|
| 53 | ||||
|
|
|
|
|
|
|
| WATTS |
| 340 |
| 405 |
| 445 |
|
| 390 |
|
| 355 | |||
NOTES: * First letter may be "A" or "T" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
** Factory setting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*UH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER | |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
OUTDOOR | AIRFLOW |
|
| DIP SWITCH SETTING |
|
| EXTERNAL STATIC PRESSURE | ||||||||||||||||
UNIT SIZE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
SETTING |
| SW 1 |
| SW 2 |
| SW 3 |
| SW 4 |
|
| 0.1 |
| 0.3 | 0.5 |
|
| 0.7 |
| 0.9 | ||||
(TONS) |
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOW |
| ON |
| ON |
|
| OFF |
| ON | CFM | 575 |
| 575 | 575 |
|
| 550 |
| - | |||
| (350 CFM/TON) |
|
|
|
|
| WATTS | 65 |
| 90 | 125 |
|
| 155 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
1.5 | NORMAL |
| ON |
| ON |
|
| OFF |
| OFF | CFM | 640 |
| 640 | 640 |
|
| 630 |
| - | |||
(400 CFM/TON) |
|
|
|
|
| WATTS | 70 |
| 110 | 140 |
|
| 175 |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| HIGH |
| ON |
| ON |
|
| ON |
| OFF | CFM | 700 |
| 700 | 700 |
|
| 700 |
| - | |||
| (450 CFM/TON) |
|
|
|
|
| WATTS | 85 |
| 125 | 160 |
|
| 200 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| LOW |
| OFF |
| ON |
|
| OFF |
| ON | CFM | 700 |
| 700 | 700 |
|
| 700 |
| - | |||
| (350 CFM/TON) |
|
|
|
|
| WATTS | 100 |
| 130 | 170 |
|
| 210 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
2.0 | NORMAL |
| OFF |
| ON |
|
| OFF |
| OFF | CFM | 800 |
| 800 | 800 |
|
| 800 |
| - | |||
(400 CFM/TON) |
|
|
|
|
| WATTS | 115 |
| 155 | 200 |
|
| 250 |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| HIGH |
| OFF |
| ON |
|
| ON |
| OFF | CFM | 900 |
| 900 | 900 |
|
| 900 |
| - | |||
| (450 CFM/TON) |
|
|
|
|
| WATTS | 140 |
| 195 | 240 |
|
| 290 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| LOW |
| ON |
| OFF |
|
| OFF |
| ON | CFM | 875 |
| 875 | 875 |
|
| 875 |
| - | |||
| (350 CFM/TON) |
|
|
|
|
| WATTS | 130 |
| 180 | 230 |
|
| 270 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
2.5 | NORMAL |
| ON |
| OFF |
|
| OFF |
| OFF | CFM | 1000 |
| 1000 | 1000 |
| 1000 | 900 | |||||
(400 CFM/TON) |
|
|
|
|
| WATTS | 175 |
| 235 | 285 |
|
| 335 |
| 310 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| HIGH |
| ON |
| OFF |
|
| ON |
| OFF | CFM | 1125 |
| 1125 | 1125 |
| 1100 | 925 | |||||
| (450 CFM/TON) |
|
|
|
|
| WATTS | 235 |
| 295 | 345 |
|
| 370 |
| 318 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
3 | LOW |
| OFF |
| OFF |
|
| OFF |
| ON | CFM | 1050 |
| 1050 | 1050 |
| 1050 | 920 | |||||
(350 CFM/TON) |
|
|
|
|
| WATTS | 195 |
| 260 | 305 |
|
| 350 |
| 315 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| NORMAL |
| OFF |
| OFF |
|
| OFF |
| OFF | CFM | 1200 |
| 1200 | 1200 |
| 1100 | 940 | |||||
| (400 CFM/TON) |
|
|
|
|
| WATTS | 275 |
| 330 | 385 |
|
| 385 |
| 330 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| HIGH |
| OFF |
| OFF |
|
| ON |
| OFF | CFM | 1325 |
| 1325 | 1300 |
| 1175 | 1000 | |||||
| (450 CFM/TON) |
|
|
|
|
| WATTS | 360 |
| 425 | 460 |
|
| 425 |
| 365 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES: * First letter may be "A" or "T"
1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
9
Pub. No.