1st Stage Capacity =

*UH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

 

 

 

 

 

 

 

1st Stage Capacity =

37,830

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2nd Stage Capacity =

58,200

 

 

 

 

 

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

 

SW 7

 

SW 8

 

 

 

 

 

0.1

 

0.3

 

0.5

 

 

0.7

 

 

0.9

 

 

 

 

 

 

 

 

 

CFM

 

600

 

600

 

600

 

 

600

 

 

 

 

LOW

 

ON

 

ON

 

TEMP. RISE

 

57

 

57

 

57

 

 

57

 

 

-

 

 

 

 

 

 

 

 

WATTS

 

85

 

110

 

155

 

 

190

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

700

 

700

 

700

 

 

700

 

 

 

HEATING

MEDIUM LOW

 

OFF

 

ON

 

TEMP. RISE

 

49

 

49

 

49

 

 

49

 

 

-

 

 

 

 

 

 

 

WATTS

 

90

 

130

 

175

 

 

210

 

 

 

1ST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

775

 

775

 

775

 

 

775

 

 

 

STAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL **

 

ON

 

OFF

 

TEMP. RISE

 

44

 

44

 

44

 

 

44

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATTS

 

105

 

155

 

195

 

 

240

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

870

 

870

 

870

 

 

870

 

 

 

 

HIGH

 

OFF

 

OFF

 

TEMP. RISE

 

39

 

39

 

39

 

 

39

 

 

-

 

 

 

 

 

 

 

 

WATTS

 

135

 

185

 

235

 

 

290

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

860

 

920

 

920

 

 

920

 

 

670

 

LOW

 

ON

 

ON

 

TEMP. RISE

 

61

 

57

 

57

 

 

57

 

 

79

 

 

 

 

 

 

 

 

WATTS

 

140

 

200

 

245

 

 

300

 

 

245

 

 

 

 

 

 

 

 

 

CFM

 

1000

 

1000

 

1000

 

 

1000

 

700

HEATING

MEDIUM LOW

 

OFF

 

ON

 

TEMP. RISE

 

53

 

53

 

53

 

 

53

 

 

75

 

 

 

 

 

 

 

WATTS

 

190

 

255

 

305

 

 

340

 

 

255

2ND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

1125

 

1125

 

1125

 

 

1025

 

775

STAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL **

 

ON

 

OFF

 

TEMP. RISE

 

47

 

47

 

47

 

 

51

 

 

68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATTS

 

250

 

315

 

370

 

 

355

 

 

285

 

 

 

 

 

 

 

 

 

CFM

 

1250

 

1250

 

1250

 

 

1100

 

1000

 

HIGH

 

OFF

 

OFF

 

TEMP. RISE

 

42

 

42

 

42

 

 

48

 

 

53

 

 

 

 

 

 

 

 

WATTS

 

340

 

405

 

445

 

 

390

 

 

355

NOTES: * First letter may be "A" or "T"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** Factory setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*UH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

AIRFLOW

 

 

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

UNIT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING

 

SW 1

 

SW 2

 

SW 3

 

SW 4

 

 

0.1

 

0.3

0.5

 

 

0.7

 

0.9

(TONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

ON

 

ON

 

 

OFF

 

ON

CFM

575

 

575

575

 

 

550

 

-

 

(350 CFM/TON)

 

 

 

 

 

WATTS

65

 

90

125

 

 

155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5

NORMAL

 

ON

 

ON

 

 

OFF

 

OFF

CFM

640

 

640

640

 

 

630

 

-

(400 CFM/TON)

 

 

 

 

 

WATTS

70

 

110

140

 

 

175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

ON

 

ON

 

 

ON

 

OFF

CFM

700

 

700

700

 

 

700

 

-

 

(450 CFM/TON)

 

 

 

 

 

WATTS

85

 

125

160

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

OFF

 

ON

 

 

OFF

 

ON

CFM

700

 

700

700

 

 

700

 

-

 

(350 CFM/TON)

 

 

 

 

 

WATTS

100

 

130

170

 

 

210

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.0

NORMAL

 

OFF

 

ON

 

 

OFF

 

OFF

CFM

800

 

800

800

 

 

800

 

-

(400 CFM/TON)

 

 

 

 

 

WATTS

115

 

155

200

 

 

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

OFF

 

ON

 

 

ON

 

OFF

CFM

900

 

900

900

 

 

900

 

-

 

(450 CFM/TON)

 

 

 

 

 

WATTS

140

 

195

240

 

 

290

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

ON

 

OFF

 

 

OFF

 

ON

CFM

875

 

875

875

 

 

875

 

-

 

(350 CFM/TON)

 

 

 

 

 

WATTS

130

 

180

230

 

 

270

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

NORMAL

 

ON

 

OFF

 

 

OFF

 

OFF

CFM

1000

 

1000

1000

 

1000

900

(400 CFM/TON)

 

 

 

 

 

WATTS

175

 

235

285

 

 

335

 

310

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

ON

 

OFF

 

 

ON

 

OFF

CFM

1125

 

1125

1125

 

1100

925

 

(450 CFM/TON)

 

 

 

 

 

WATTS

235

 

295

345

 

 

370

 

318

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

LOW

 

OFF

 

OFF

 

 

OFF

 

ON

CFM

1050

 

1050

1050

 

1050

920

(350 CFM/TON)

 

 

 

 

 

WATTS

195

 

260

305

 

 

350

 

315

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL

 

OFF

 

OFF

 

 

OFF

 

OFF

CFM

1200

 

1200

1200

 

1100

940

 

(400 CFM/TON)

 

 

 

 

 

WATTS

275

 

330

385

 

 

385

 

330

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

OFF

 

OFF

 

 

ON

 

OFF

CFM

1325

 

1325

1300

 

1175

1000

 

(450 CFM/TON)

 

 

 

 

 

WATTS

360

 

425

460

 

 

425

 

365

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES: * First letter may be "A" or "T"

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.