General
Data
TUH2/TDH2 PRODUCT SPECIFICATIONS1
PRODUCT SPECIFICATIONS 1
MODEL | TUH2C100A9V5VA | TUH2D120A9V5VA | TDH2B060A9V3VA | TDH2B080A9V3VA |
TYPE | Upflow / Horizontal | Upflow / Horizontal | Downflow / Horizontal | Downflow / Horizontal |
RATINGS 2 |
|
|
|
|
1st Stage Input BTUH | 65,000 | 78,000 | 39,000 | 52,000 |
1st Stage Capacity BTUH (ICS) 3 | 62,855 | 75,426 | 37,000 | 49,400 |
2nd Stage Input BTUH | 100,000 | 120,000 | 60,000 | 80,000 |
2nd Stage Capacity BTUH (ICS) 3 | 96,700 | 116,040 | 57,000 | 76,000 |
AFUE | 96.7 | 96.7 | 95 | 95 |
Temp. rise | 35 - 65 | 40 - 70 | 35 - 65 | 35 - 65 |
BLOWER DRIVE | DIRECT | DIRECT | DIRECT | DIRECT |
Diameter - Width (In.) | 11 x 10 | 10 x 10 | 10 x 8 | 10 x 8 |
No. Used | 1 | 1 | 1 | 1 |
Speeds (No.) | Variable | Variable | Variable | Variable |
CFM vs. in. w.g. | See Fan Performance Table | See Fan Performance Table | See Fan Performance Table | See Fan Performance Table |
Motor HP | 1 | 1 | 1/2 | 1/2 |
R.P.M. | Variable | Variable | Variable | Variable |
Volts / Ph / Hz | 115/1/60 | 115/1/60 | 115/1/60 | 115/1/60 |
COMBUSTION FAN - Type | Centrifugal | Centrifugal | Centrifugal | Centrifugal |
Drive - No. Speeds | Direct - Variable | Direct - Variable | Direct - Variable | Direct - Variable |
Motor HP - RPM | 1/50 - 5000 | 1/50 - 5000 | 1/50 - 5000 | 1/50 - 5000 |
Volts / Ph / Hz | 33 - 110/3/60 - 180 | 33 - 110/3/60 - 180 | 33 - 110/3/60 - 180 | 33 - 110/3/60 - 180 |
FLA | 1.0 | 1.0 | 1.0 | 1.0 |
FILTER — Furnished? | Yes | Yes | Yes | Yes |
Type Recommended | High Velocity | High Velocity | High Velocity | High Velocity |
Hi Vel. | 1 - 20x25 - 1 in. | 1 - 24x25 - 1 in. | 2 - 14x20 - 1 in. | 2 - 14x20 - 1 in. |
VENT — Size (in.) | 3 Round | 3 Round | 2 Round | 2 Round |
HEAT EXCHANGER |
|
|
|
|
Type | Aluminized Steel - Type I | Aluminized Steel - Type I | Aluminized Steel - Type I | Aluminized Steel - Type I |
|
|
|
| |
Gauge (Fired) | 20 | 20 | 20 | 20 |
ORIFICES — Main |
|
|
|
|
Nat. Gas. Qty. — Drill Size | 5 — 45 | 6 — 45 | 3 — 45 | 4 — 45 |
L.P. Gas Qty. — Drill Size | 5 — 56 | 6 — 56 | 3 — 56 | 4 — 56 |
GAS VALVE | Redundant - Two Stage | Redundant - Two Stage | Redundant - Two Stage | Redundant - Two Stage |
PILOT SAFETY DEVICE |
|
|
|
|
Type | Hot Surface Igniter | Hot Surface Igniter | Hot Surface Igniter | Hot Surface Igniter |
BURNERS — Type | Multiport Inshot | Multiport Inshot | Multiport Inshot | Multiport Inshot |
Number | 5 | 6 | 3 | 4 |
POWER CONN. — V / Ph / Hz 4 | 115/1/60 | 115/1/60 | 115/1/60 | 115/1/60 |
Ampacity (In Amps) | 16.3 | 15.2 | 11.1 | 11.1 |
Max. Overcurrent Protection (Amps) | 20 | 20 | 15 | 15 |
PIPE CONN. SIZE (IN.) | 1/2 | 1/2 | 1/2 | 1/2 |
DIMENSIONS | H x W x D | H x W x D | H x W x D | H x W x D |
Crated (In.) | ||||
WEIGHT |
|
|
|
|
Shipping (Lbs.) / Net (Lbs) | 199 / 187 | 206 / 193 | 160/ 146 | 168 / 158 |
1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3Based on U.S. government standard tests.
4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
Pub. No. | 7 |