Ruud AP13370-2 installation instructions Installing the water heater, Location

Page 7

Installing the water heater.

This water heater must be installed in accordance with these instructions, local codes, utility company requirements, and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400 N. Capitol Street NW, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269 as booklet NFPA 54. Or in Canada, CAN/CSA B149 - Natural Gas and Propane Installation Code. A copy can be purchased from the Canadian Standards Association, 5060 Spectrum Way, Mississauga, Ontario, Canada L4W 5N6.

Max.

2”

(5cm)

Diameter of water heater

plus 2”

(5cm) min.

The auxiliary catch pan installation MUST conform to local codes.

!WARNING: Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or flammable products and materials. Combustible and/or flammable products and materials should never be stored in the vicinity of this or any gas appliance.

Location

The water heater should not be located in an area where leakage from the tank or connections will result in damage to the area adjacent to the heater or to lower floors of the structure.

When such areas cannot be avoided it is recommended that a suitable catch pan, adequately drained, must be installed under the water heater.

The pan must not restrict the lower air inlet box located around the lower perimeter of the water heater.

Catch pan kits are available from the store where the water heater was purchased, or any water heater distributor.

A gas fired water heater or any other appliance should not be installed

in a space where liquids which give off flammable vapors are to be used or stored. Such liquids include gasoline, LP gas (butane or propane), paint or adhesives and their thinners, solvents or removers.

Because of natural air movement in a room or other enclosed space, flammable vapors can be carried some distance from where liquids which give off flammable vapors are to be used or stored. The open flame of the water heater’s pilot or main burner can ignite these vapors.

The water heater must be located so it is not subject to physical damage, for example, by moving vehicles, area flooding, etc.

For these reasons installation of a gas fired water heater in a garage is not desirable.

Make certain the floor underneath the water heater is strong enough to sufficiently support the weight of the water heater once it is filled with water.

If local codes require the use of a stand kit to raise the water heater 18” (46cm) above the floor, please contact the store where the water heater was purchased, or any water heater distributor. These kits must comply with local codes.

The water heater should be installed as close as practical to the gas vent or chimney.

Long hot water lines should be insulated to conserve water and energy.

The water heater and water lines should be protected from exposure to freezing temperatures.

Do not install the water heater in bathrooms, bedrooms, any occupied rooms normally kept closed, or in unprotected outdoor areas.

Minimum clearance from combustible construction is 0” (0cm) sides, 0” (0cm) rear; and 3” (7.6cm) from the front of the control. If the clearances stated on the Instruction/Warning Label, located on the front of the heater differ, install the water heater according to the clearances stated on the label.

The water heater may be installed on combustible floors, but not directly on carpeting. If the water heater must be installed on carpeting, place a metal or wood panel beneath the water heater, extending beyond its full width and depth at least 3” (7.6cm) in all directions.

If the water heater is installed in an alcove or closet, the entire floor must be covered by a wood or metal panel. A minimum of 24” (61cm) clearance from the front and top should be available for adequate inspection and servicing.

7

Image 7
Contents Water Heaters For Your Records N G E R Water Temperature Setting Page Read and Follow this Safety Information Carefully Location Installing the water heaterCombustion and Ventilation Air Inspect ShipmentCorrosive Atmospheres Venting Horizontal Vent Terminal Location Blower Assembly InstallationAdditional Considerations Joining Pipes and Fittings Minimum and Maximum Vent LengthCementing Joints Vertical Vent Termination Horizontal Vent InstallationDraining the Condensate Water Supply Connections Thermal ExpansionRelief Valve Gas Supply Leak TestingTo Fill the Water Heater CondensationWiring Pressure Testing the Gas Supply SystemHigh Altitude Insulation Blankets Hot and Cold Pipe Insulation InstallationHeat Trap Typical Installation Water Heater Location Installation ChecklistWater Supply Combination Potable and Space Heating Application Lighting the water heater Water Temperature Setting AdjustmentsOperating the water heater Water Temperature Setting… Draining the Water Heater Routine Preventative MaintenanceHousekeeping Anode Rod Venting System InspectionBurner Inspection Vacation and Extended Shut-DownProblem Possible Causes What To Do Before You Call For Service…No hot water Exceeded the capacity Water heater Gas Valve Error Code TableInstructions For Placing a Parts Order Replacement PartsIf YOU Need Service